Summary
The authors tackle an increasingly important issue in scientific research: the use of LLMs in automating hypothesis testing. The authors introduce a new benchmark task, P-bench, that contains 425 open-ended hypothesis testing problems. This benchmark goes beyond existing benchmarks by explicitly assessing for the validity behind an LLM's conclusions following a statistical test and p-value. The problems spanned multiple domains including biology, economics, and medicine. The authors also introduce a model fine-tuned for hypothesis testing, Fisher-R1. Their results demonstrated that this fine-tuned model outperforms other models on the P-bench.
Strengths and weaknesses
Strengths: The authors make a very perceptive observation regarding the state of LLM capabilities and limitations of current benchmarks. The P-bench is very well designed and representative of real-world problems that LLMs have been used for. The Fisher-R1 model is thoughtfully constructed. Overall, this paper has many strengths and is technically sound.
Weaknesses: Currently, all these are assuming alpha = 0.05. Sometimes, a small p-value may just indicate a study being under-powered. Additionally, it may be worth mentioning how LLMs would reason through adjusting for multiple-comparisons (e.g., choosing appropriate adjustment method, adjusting across which comparisons, etc.). In the same vein, different fields have different thresholds for alpha. How would an agent reason through choice of threshold? The authors noted these issues in the Discussion.
Secondly, scientific hypotheses are not always tested through frequentist, inferential methods (i.e., p-value computation and evaluation). It may be worth mentioning, even briefly, in the discussion how the Fisher-R1 model may be extended to Bayesian analyses (assessing Bayes Factor in lieu of p-value).
Overall, great paper. It's clear that it yields strong preliminary work. Discussion on other techniques for scientific inference would further strengthen the paper.
Questions
-
How would you extend Fisher-R1 to consider other methods of hypothesis testing that are not based on frequentist p-values? For example, Bayesian analyses.
-
The choice of alpha is arbitrary. A human agent will choose a threshold based on their risk tolerance. How would a model like Fisher-R1 pick a threshold?
-
How would Fisher-R1 interpret a significant p-value but a small effect size? In a lot of clinical research, a small p-value is not meaningful without evidence of strong clinical significance (large effect size).
Limitations
Mostly. Several limitations to discuss are noted above (Bayesian methods, arbitrary choice of alpha, consideration of effect size).
Paper formatting concerns
No formatting concerns
We thank the Reviewer for the constructive comments and respond to each point below.
We added 30 benchmark tasks specifically designed to evaluate multiple-testing scenarios. A response is correct only if it identifies the appropriate hypothesis family, applies a valid procedure, and produces the correct adjusted decision for every hypothesis. Across three runs, Fisher-R1 achieves 83.3% accuracy, compared with 61.1% for its backbone, despite receiving no direct training on multiple-testing tasks. We will add this analysis and explicitly discuss multiple-comparison reasoning as an important extension of P-Bench.
Fisher-R1 can be extended by replacing the p-value target with an inference-specific, verifiable outcome. For Bayesian analyses, each training task would specify a likelihood and prior, and the agent would compute the Bayes factor. The RL reward would assess both log-Bayes-factor accuracy and consistency between the computed BF10 and the reported direction of evidence. As a preliminary evaluation, we have added a 30-task benchmark spanning six conjugate model families. Despite receiving no Bayesian-specific training, Fisher-R1-14B produces a valid numerical BF10 on 91.1% of tasks, compared with 68.9% for its Qwen2.5-Coder-14B backbone. Among the 24 tasks with an unambiguous evidence direction, Fisher-R1 correctly determines whether the evidence favors H0 or H1 in 56.9% of cases, versus 40.3% for the backbone. These results indicate partial zero-shot generalization beyond p-value-based inference, while the modest absolute accuracy highlights the need for Bayesian-specific SFT and RL.
We clarify that Fisher-R1 is not intended to infer a universally correct significance threshold from the observed data. The choice of threshold reflects the researcher’s tolerance for risk, including the relative costs of false-positive and false-negative conclusions, as well as relevant disciplinary or regulatory conventions. In open-ended settings, the model should therefore elicit this information from the user. If no threshold is provided, it should clearly state any conventional value it assumes and report a sensitivity analysis across plausible thresholds rather than silently defaulting to 0.05.
Once the threshold has been prespecified, the model’s role is to apply it consistently. In our paired evaluation at thresholds of 0.1, 0.01, and 0.001, Fisher-R1’s final decision was consistent with its reported p-value and the requested threshold in 84.8% of outputs, compared with 61.5% for its backbone model. Our results therefore evaluate threshold-conditioned inference while treating the threshold itself as a transparent, researcher-specified decision parameter.
We additionally evaluated Fisher-R1 on 30 P-Bench tasks in which neither the user nor system prompt specified a significance threshold. In 22 cases (73.3%), Fisher-R1 explicitly adopted the conventional threshold of 0.05. In six cases (20.0%), it reached a threshold-robust conclusion because the p-value fell well above or below multiple conventional cutoffs. In the remaining two cases (6.7%), the threshold was left unspecified. These results further illustrate that, without explicit prompting, Fisher-R1 generally applies a conventional significance threshold (alpha = 0.05).
We agree that statistical significance is not equivalent to clinical significance. A small p-value provides evidence against the null hypothesis but does not indicate whether the effect size is clinically meaningful. Fisher-R1 should therefore report and interpret effect estimates and confidence intervals separately from p-values. Although our current prompt requests these quantities, the P-Bench reward does not explicitly evaluate their clinical interpretation. We will clarify this limitation and identify effect-size interpretation as an important direction for extending the benchmark and reward function.
To assess this capability, we introduced 30-task benchmarks spanning six analysis families and five combinations of statistical and clinical significance (large effect size). Fisher-R1-14B outperforms its Qwen2.5-Coder-14B backbone in determining whether the confidence interval lies above, below, or overlaps a prespecified effect size (63.3% vs. 53.3%). These results show that Fisher-R1’s gains extend beyond p-value reasoning to effect-size interpretation.