- Rating
- 3
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper studies selective auto-labeling, where the goal is to accept a subset of automatically generated labels while controlling the error rate among the accepted labels. The authors propose Conformal Labeling, which formulates the decision of accepting each auto-label as a multiple hypothesis testing problem. Using a small labeled calibration set, the method constructs conformal p-values based on the uncertainty scores of known incorrect auto-labels, and then applies a modified BH procedure with a correction factor. The paper proves finite-sample control of the FLR, analyzes asymptotic power optimality under fixed uncertainty scores, and evaluates the method on image classification, multiple-choice QA, and open-ended generation tasks.
Strengths and weaknesses
Strengths :This paper tries to selectively trust auto-generated labels while controlling the error rate among the accepted labels. The proposed method is practically motivated, and the formulation of selective auto-labeling as a multiple testing problem is clean and intuitive. The use of a small calibration set to construct conformal p-values, together with a BH-style selection rule, gives the method a clear statistical interpretation. The calibration-based correction factor is also useful, as it reduces the conservativeness of standard BH when the base auto-labeling model is relatively accurate. Empirically, the paper evaluates the method across image classification, multiple-choice QA, and open-ended generation tasks, and the results generally show favorable trade-offs between FLR control and power.
Weaknesses :My main concern is the positioning and novelty. The overall pipeline of constructing conformal p-values from a labeled calibration set followed by a BH-type procedure appears closely related to prior work on conformal selection and conformal alignment. In this light, the main contribution seems to be the calibration-based correction factor, the adaptation to selective auto-labeling, and experiments on generation tasks. These are useful, but the paper could more clearly distinguish itself from prior work rather than presenting the framework as broadly new.
Another concern is practical risk interpretation. The FLR guarantee is marginal over the calibration and test randomness, while practitioners typically apply the method once to a fixed dataset. The realized FLP may exceed the target level in a single run, and the paper could better quantify this risk. Relatedly, the method can behave less stably when few or no calibration errors are observed, which is especially relevant for highly accurate models with small calibration sets.
Finally, the cost-saving motivation is less convincing for some generation experiments, where the calibration set is large relative to the test set. An explicit accounting of annotation cost spent versus labels saved would make the practical benefit clearer. Overall, this paper presents a useful and reasonably well-executed study, but the novelty and practical risk discussion should be sharpened.
Questions
- Please clarify the relationship to conformal alignment (Gui et al. 2024). Is the BH baseline in Table 3 equivalent to applying their procedure here? If the contribution beyond [52] is the correction factor, I would like the introduction and related work to say so explicitly. A clear answer here is the main thing that would move my score.
- Can you report the distribution of realized FLP rather than only its mean — e.g., P(FLP > α) or the 90th percentile — across the 1000 repetitions, particularly for small n and the highly accurate models? Given footnote 1 and the n0=0 results, readers should know how often a single run violates the target and by how much.
- Can you provide practical guidance on choosing the calibration size given a target and an anticipated auto-labeling error rate? In particular, how large should be so that is likely large enough for the conformal p-values to be informative?
Limitations
Yes
Paper formatting concerns
None
Final justification
The authors have provided a convincing rebuttal that substantially addresses my initial concerns regarding the novelty positioning, practical applicability, and reliability of the proposed Conformal Labeling framework. In particular, the clarification of its relationship with conformal selection/alignment methods makes the contribution more clearly positioned, while the additional experiments on realized FLP distribution, calibration size guidance, and large-scale annotation cost analysis provide stronger evidence for the practical value of the method. Although some limitations remain, such as the dependence on calibration quality and the need for further theoretical characterization under more challenging settings, the authors have adequately responded to the major concerns and improved the overall confidence in the contribution. Therefore, I revise my initial negative assessment and move the score toward a weak accept.
Meta-review
This paper proposes Conformal Labeling, a principled framework for selective auto-labeling that casts the selection of reliable auto-generated labels as a multiple testing problem. Reviewers agree that the paper addresses an important and practical problem, and highlight the method’s clean formulation, strong statistical grounding, and appealing finite-sample guarantees. At the same time, several key issues are raised that would benefit from clarification in the rebuttal. In particular, reviewers note that the novelty relative to closely related conformal selection and threshold-based auto-labeling methods should be more clearly articulated and empirically validated. Additionally, the scope and interpretation of the reliability guarantee require more careful discussion, especially regarding its marginal nature, behavior under distribution shift, and implications for single-run deployments. Reviewers also request clearer guidance on practical aspects such as uncertainty score selection, calibration size, and more realistic large-scale evaluation settings.