- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper proposes MEDPSY, a family of compact medical language models (1.7B and 4B parameters) designed for privacy-preserving edge deployment. This work addresses the central challenge of bridging the capability gap between deployable small medical LLMs and larger cloud-based medical models.
The authors build MEDPSY on top of Qwen3 backbones and introduce an integrated four-stage post-training pipeline consisting of two supervised fine-tuning (SFT) stages and two reinforcement learning (RL) stages. The training data is constructed from synthetic medical corpora generated using public biology, medicine, and healthcare seed datasets, while chain-of-thought supervision is distilled from a large 235B medical teacher model (Baichuan-M3-235B).
The models are evaluated on seven closed-ended medical benchmarks and HealthBench/HealthBench-Hard. Experimental results demonstrate that MEDPSY-4B achieves performance comparable to MedGemma-27B while being significantly smaller, and MEDPSY-1.7B surpasses MedGemma-1.5-4B despite having fewer parameters. The paper also studies token efficiency and quantization, showing that 4-bit quantization retains most of the original performance while enabling practical deployment on resource-constrained devices.
Strengths and weaknesses
Strengths:
- From a quality perspective, the experimental study is extensive. The authors evaluate the models across multiple closed-ended medical benchmarks, open-ended HealthBench evaluations, stage-wise ablations, teacher selection experiments, and quantization analyses. The inclusion of both deployment-oriented metrics (token efficiency and quantization robustness) and reasoning benchmarks significantly strengthens the empirical contribution.
- systematic design of the post-training pipeline. Rather than proposing a single algorithmic novelty, the paper carefully integrates synthetic data generation, curriculum learning, hard-sample mining, and reinforcement learning into a unified framework. The stage-wise analysis provides useful insights into the contribution of each training stage.
- The deployment aspect is particularly valuable. Many medical LLM papers exclusively focus on accuracy, whereas this work additionally studies memory footprint, response length reduction, and low-bit quantization. These practical considerations enhance the real-world relevance of the work.
Weaknesses
- The novelty is somewhat limited from an algorithmic perspective. Most individual components—including synthetic data generation, curriculum SFT, DAPO-based RL, hard-sample mining, and chain-of-thought distillation—are adaptations of existing techniques. The main contribution lies in the engineering integration of these components rather than introducing fundamentally new methodologies. The paper should better articulate what is genuinely novel beyond assembling prior approaches.
- The evaluation heavily relies on LLM-as-Judge and LLM-as-Parser paradigms. Although the authors mitigate this by employing multiple judges and parsers, these evaluations may still introduce biases. Human expert evaluations would substantially strengthen the claims, especially for medical applications where factual correctness and safety are critical.
- Although the paper emphasizes edge deployment, inference latency and energy consumption are not directly measured on real devices. Reporting only disk footprint and token counts provides an incomplete picture of practical deployment feasibility.
Questions
-
The paper integrates several existing components (synthetic data generation, DAPO, hard-sample mining, curriculum learning). Could the authors explicitly quantify the individual contribution of each component relative to prior work? This would help clarify the novelty of the proposed pipeline.
-
Can the authors provide human expert evaluations (e.g., physicians or medical professionals) on a subset of HealthBench examples? This would validate whether the improvements observed under LLM judges translate into clinically meaningful improvements.
-
Could the authors provide a failure analysis of MEDPSY? For example, what categories of errors remain common, such as hallucinations, incorrect diagnoses, unsafe recommendations, or overconfident responses?
-
Since edge deployment is a central motivation, can the authors report actual deployment metrics on representative hardware (e.g., smartphones, laptops, or embedded devices), including latency, throughput, memory consumption, and energy usage?
Limitations
yes
Paper formatting concerns
no
Final justification
I have raised my score based on the authors responses.
We thank you for a careful review and for recognising the breadth of the experimental study and the value of the deployment analysis. We agree that it is important to delve deeper into your concerns regarding the clarity of contributions, validation of results, and edge metrics.
Response to Q1. Explicit per-component attribution
While we agree that the novelty is limited from an algorithmic perspective, our work makes 2 contributions that are supported by quantitative evidence.
1. Synthetic data generation and CoT distillation Unlike prior work on open medical SFT collections that mix heterogeneous traces, for example II-Medical combines public R1 traces with Qwen3-generated traces, while OpenMed combines traces from seven source models, we regenerate every assistant target with one teacher (§3.1); teacher selection is reported in §3.2 and App. A.2. To quantify target consistency, we train three 4B students with the same 170K prompts, base model, and pipeline, varying only the target source; this ablation will be added to the appendix.
Closed-ended averages vary by only 0.41 points, but HealthBench changes markedly: the mixed model (60.0) remains near Fleming-only (59.5), rather than the midpoint of the single-teacher models (65.25), while Baichuan-only reaches 71.0. Thus, our contribution is not a new distillation algorithm, but controlled evidence that mixing heterogeneous target teachers provides no benefit here and is consistent with a less coherent SFT signal.
2. Reinforcement Learning (DAPO & hard-sample mining)
Our second key contribution is not the introduction of a new RL algorithm, but a set of empirical findings that identify which design choices are effective for small medical reasoning models:
We present our findings in the following consolidated summary table, making these isolated contributions explicit. Each measured performance delta directly quantifies the contribution of that component relative to prior work.
Response to Q2. Human expert evaluation
While it's in our plan to include human evaluation in the future, currently our team has no physicians or medical professionals. However, HealthBench (Arora et al., 2025) evaluates 5,000 conversations using physician-written rubrics with 48,562 criteria authored by 262 practising physicians. The LLM judge checks each physician-written criterion rather than choosing a preferred response; thus, checking is automated but the standard is human-expert.
Graders can misapply criteria and differ in strictness, which can add variance. We therefore used three independent model-family judges (§5.3). Absolute scores vary but the complete five-model ranking is identical in all six (judge × split) cells, and every pairwise margin retains its sign. Strictness rescales the axis without reordering models, supporting clinically meaningful improvement. Future work will add OpenAI's recently released HealthBench Professional, where ≥3 physicians validate each sample.
Response to Q3. Failure analysis: which errors remain?
Two complementary HealthBench breakdowns characterize MedPsy's failures.
The theme-level breakdown in Appendix A.8 shows where failures occur. Weakest are Health Data and Response Depth: on HealthBench-Hard, 4B scores 46.67 and 47.67, versus 1.7B's 43.33 and 40.33. This indicates recurring difficulty interpreting complex medical information.
The axis breakdown shows how quality deteriorates. Lowest are context awareness and instruction following, indicating missed situational cues or constraints and incomplete execution of complex instructions. This breakdown will be added to the appendix.
Response to Q4. Real-device deployment metrics
As requested, we evaluated MedPsy on an Apple M5 Pro (llama.cpp Metal) and OnePlus 13. Laptop models used thinking mode, fixed decoding, and 8,192-token context. Energy equals measured sustained SoC power from powermetrics (26.5 W) × end-to-end wall time.
Laptop: Apple M5 Pro
The 30 board-style questions comprised 20 MedQA and 10 MedXpertQA-Text; 1.7B and both 4B variants achieved 0.60 accuracy. At matched Q4_K_M, MedPsy-4B and Qwen3-4B-Thinking decode comparably (83.9 vs 82.2 tok/s), so reasoning length drives the end-to-end difference. MedPsy uses 73% fewer tokens, with 75% lower latency and 63% lower estimated energy. Accuracy is 0.600 vs 0.433 overall and 0.200 vs 0.000 on MedXpertQA. For MedPsy-4B, IQ3_M lowers peak memory from 4.29 to 3.66 GB and raises throughput from 83.9 to 95 tok/s, with unchanged accuracy.
Smartphone: OnePlus 13
We used a OnePlus 13 (CPH2649IN), Android 16, Adreno 830, and llama.cpp Android build 9226 with Vulkan partial offload (-ngl 20) and six CPU threads. Each battery run used three MedQA prompts, 8,192-token context, 2,048-token completion limit, and seed 42.
Energy came from the Android battery charge counter over Wi-Fi debugging on an unplugged, 49%-charged device. MedPsy-1.7B uses ≈2.2 GB RAM and decodes at 15.3 tok/s; 4B uses ≈4.0 GB and 6.63 tok/s. These results demonstrate fully local execution of both variants on a flagship Android phone.