- Rating
- 5
- Clarity
- 2
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper proposes a new test-time adaptation method for OOD detection with VLM models like CLIP. The core idea is to analyze the class-wise posterior distribution of unlabeled test samples and use optimal transport to correct this distribution toward a balanced uniform class prior. The motivation of the paper is that the confidence scores produced by zero-shot VLMs are less reliable for OOD detection compared to supervised classifiers. Based on this observation, the authors propose their method.
Strengths and weaknesses
Strengths
- The paper presents an observation and proposes a solid method.
- The empirical evaluation is also comprehensive, and the results show that the proposed method achieves state-of-the-art performance across several benchmarks.
Weaknesses
- The central observation and the accompanying theory are both somewhat obvious and, on closer inspection, misleading. In a fully separable setting, it is self-evident that a supervised method trained on the target labels will outperform a transferred zero-shot one; this requires no formal proof. In the more realistic setting that actually matters (like in low-quality or limited-sample conditions), however, this observation breaks down: prior work such as MCM has already demonstrated that CLIP-based zero-shot OOD detection can in fact outperform most earlier supervised OOD detection methods on the ImageNet-1K benchmark.
- I suggest using the classical OOD detection metrics, AUROC and FPR95, as the main evaluation metrics, and presenting the ImageNet-1K setting as the main experimental result. This would make the comparison with prior CLIP-based OOD detection methods more direct. The current presentation starts with datasets such as CUB-200-2011 and Stanford Cars as ID datasets, while ImageNet-1K is usually the standard benchmark in this literature. The comparison could also be expanded to include more recent methods such as AdaNeg, LAPT, and NegRefine.
- The metric Acc_S can decrease not only when ID samples are incorrectly rejected as OOD, but also when ID samples are misclassified as another ID class. Since the main focus of the paper is OOD detection, AUROC and FPR95 may provide a cleaner and more reliable evaluation of OOD detection performance.
- The proposed method is hard to follow. Although the high-level idea of making the posterior distribution more balanced or uniform is clear, the full pipeline, including OT rectification, should be explained more clearly and with more background.
- The evaluation setting is not described in the paper, that how the test batches are created. Do they include the same percentage of ID and OOD in each batch, or it is some other setting?
- It would be interesting to evaluate the method under more extreme test-time scenarios. For example, what happens if the model observes several consecutive batches with no OOD samples, or if the initial batches contain only OOD samples and no ID samples? The authors discuss these issues in the limitations, but empirical experiments would help clarify how robust the method is under such challenging batch compositions.
Questions
Please refer to Weaknesses.
Limitations
yes.
Paper formatting concerns
No issue.
Final justification
I believe the paper presents solid results, and the authors have clarified several of the concerns raised in my initial review. However, I still hope that they will address the comments when preparing the camera-ready version.
Response to Reviewer rCEQ
Q1 Scope of the Observation and Theoretical Analysis
We agree that a supervised classifier outperforming a transferred zero-shot model in a nearly separable setting is expected. However, Fig. 1 also reveals uneven confidence across ID classes: some classes receive consistently high confidence, while others receive weaker or more dispersed scores. This class-wise variation, hidden by aggregate comparisons, motivates using the full posterior rather than only maximum confidence.
The theory distinguishes a poor threshold from a limitation of the scalar signal: under the stated conditions, changing the threshold alone cannot recover lost ID/OOD information. It is a conditional characterization, not a universal supervised-versus-zero-shot ranking.
MCM shows that carefully designed CLIP scores can outperform earlier supervised methods, supporting our conclusion that OOD detection requires a richer signal rather than threshold adjustment alone. We will clarify this empirical contribution and theoretical scope.
Q2 & Q3 Classical OOD Metrics and Recent Baselines
We agree that AUROC and FPR95 on ImageNet provide the most direct comparison, as shown in Table 3. We add AdaNeg (NeurIPS 2024), LAPT (ECCV 2024), and NegRefine (ICCV 2025) to make the comparison more complete and provide a broader and more transparent view of recent progress. They do not exceed the strongest results in our current comparison, e.g., AdaND (ICLR 2025). For the average over iNaturalist, SUN, Textures, and Places with ImageNet-1K as ID:
For ImageNet-1K vs. iNaturalist comparing with NegRefine:
We will report the corresponding AUROC and FPR95 results for all settings, allowing both the fine-grained and ImageNet-family evaluations to be compared.
We agree with the reviewer that AccS is not a pure OOD detection metric. As noted, it can decrease either because an ID sample is rejected as OOD or because it is assigned to the wrong ID class. Our motivation for retaining AccS following AdaND is that it captures a complementary practical requirement of VLM deployment. A VLM must first correctly recognize ID inputs before its OOD-rejection capability becomes useful. Consequently, an OOD adaptation method should improve rejection without substantially degrading the model’s original ID classification ability. AccS intentionally measures this end-to-end utility.
Q4 Clarifying the SROT Pipeline
We will add more OT background, simplify the notation, expand Fig. 2 with numbered stages, and include pseudocode for the complete pipeline.
Q5 Test-Batch Construction
Following previous OOD detection work, we sample equal total numbers of ID and OOD examples, concatenate and randomly shuffle them, and then divide the resulting stream into batches. Thus, individual batches are not constrained to a fixed 50:50 ratio.
Q6 Robustness to Homogeneous Test Streams
Thanks for this interesting question! We construct challenging test streams in which the first 10, 20, or 50 consecutive batches contain either only OOD samples or only ID samples (after this, the stream returns to the standard randomly mixed setting). On ImageNet-1K vs. iNaturalist:
AUROC remains at least 99.72 and FPR95 below 1.5%. OOD-only prefixes reduce AccH by at most 0.81 points, while ID-only prefixes reduce it by 0.71–2.83 points. This asymmetry suggests that homogeneous prefixes affect subsequent pseudo-label formation. We will add these results and discuss the sensitivity to long ID-only periods.
We appreciate the reviewer’s suggestions, which have strengthened our paper’s theoretical positioning, experimental rigor, clarity, and practical relevance.