- Rating
- 4
- Clarity
- 4
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
The authors present an interesting insight that the optimal OOD detection layer depth varies across different domains, based on which they propose ML-AMCoS. The model yields promising results, supported by comprehensive ablation studies. However, the contribution of this work in terms of theoretical proof and explanation is somewhat limited, leaning more towards empirical engineering. Deepening the theoretical analysis would substantially elevate the overall quality of the paper.
Strengths and weaknesses
Strengths: 1.The paper is well written, making it easy to read and follow. 2.The model demonstrates strong experimental results across both datasets. 3.The authors' insight is quite interesting. 4.The ablation studies are comprehensive and thorough. Weaknesses: 1.The number of datasets used is quite limited (only two), with one from the natural image domain and the other from the medical image domain. This is insufficient to fully demonstrate the generalization ability of the proposed model. 2.The finding that the optimal OOD detection layer depth varies by domain (i.e., natural images favor deep features, whereas medical images favor shallow features) is intriguing. However, the discussion regarding the underlying reasons is limited and remains speculative in the text. It would significantly strengthen the paper if more convincing evidence or theoretical justifications were provided. 3.The choice of using a top-k selection mechanism to determine features at different depths appears somewhat arbitrary. 4.Utilizing shallow features to mitigate the architectural issues of overly deep networks in natural images has already been explored by prior researchers. Does this practice affect the OOD performance of the model in natural images? Furthermore, the generalization performance of such models in natural images has been well-established (e.g., ResNet is widely used as a feature extractor for transfer learning). The authors should address this and clearly clarify whether the contribution of shallow features in natural images lies in boosting model performance or enhancing generalization capability.
Questions
Deepening the theoretical analysis would substantially elevate the overall quality of the paper.
Limitations
Yes
Paper formatting concerns
No
Final justification
The author addressed the majority of my concerns, so I decided to raise my score.
Weakness 1 (Limited Datasets Used):
Thank you for raising this point. We would like to clarify that while our primary evaluation is organized into two benchmark suites (natural and medical domains), it actually spans 7 distinct datasets in total (as detailed in Section 5.1). Specifically, the natural image suite utilizes ImageNet-1K as the in-distribution (ID) dataset, evaluated against multiple standard OOD benchmarks (e.g., ImageNet-O, Textures, iNaturalist, SUN, and Places). The medical image suite incorporates three distinct datasets across diverse imaging modalities: histopathology (PatchCamelyon), laparoscopic surgical video (PhaKIR), and 3D brain MRI (OASIS-3). While no finite benchmark suite can exhaustively capture the complete diversity of both natural and clinical domains, evaluating across these 7 distinct datasets and varied modalities provides a comprehensive demonstration of our method’s generalization capability. We will refine Section 5.1 to make this dataset structure and modal breakdown more explicit.
Weakness 2 (Lack of Theoretical Analysis):
We appreciate the reviewer’s thoughtful feedback regarding our domain-specific layer findings. We acknowledge that providing a closed-form theoretical proof for feature behavior across arbitrary deep architectures remains an open challenge in the community; however, our work focuses on uncovering and validating this empirical reality through systematic, quantifiable evidence. First, we address an overlooked geometric failure mode in Mahalanobis distance (Eqs. 3–5). Existing post-hoc methods (e.g., MDSEns, ViM) operate under the assumption that incorporating the empirical precision matrix Σ^−1 always improves class separation. We reveal that this assumption breaks down in deep layers due to feature variance explosion, measured by the feature covariance trace tr(Σ^), which renders Σ^−1 ill-conditioned and amplifies sample noise (Fig. 1b). To resolve this, we propose a new scoring function Ml=λΣ^−1+(1−λ)I that dynamically interpolates between Mahalanobis distance and Cosine similarity. Unlike prior static choices, our formulation ensures that fine-grained covariance structure is exploited only when statistically reliable, automatically falling back to Cosine stability when feature variance is high. Second, we empirically demonstrate the domain-feature preference gap (Figs. 1 and 3–5) and bridge it without relying on real OOD data (Eqs. 6–8). Specifically, prior multi-layer fusion techniques are engineered around a single domain, resulting in sub-optimal performance when applied to others. For example, FeatureNorm performs well on natural images but poorly on medical tasks, whereas MBM exhibits the opposite trend, highlighting a fundamental lack of generalization in existing baselines. To address this, we propose an unsupervised Corner-Cutmixing method to synthetically generate pseudo-OOD samples. By synthesizing subtle manifold boundary perturbations on ID features alone, our method automatically identifies and prioritizes the discriminative layers for any given domain. As validated in our ranking analysis (Figs. 2, 7, and 8), our method matches the upper-bound selection quality of the supervised baseline (MDSEns) without accessing real OOD validation samples.
Weakness 3 (Arbitrary Top-k Selection):
Thank you for raising this point regarding our top-k layer selection mechanism. The choice of k=2 is an intentional design decision aimed at balancing feature richness against noise suppression. Rather than being arbitrary, selecting the top-two candidate representations serves as an effective heuristic that retains the primary discriminative signals while filtering out non-informative or noisy intermediate layers. As demonstrated by our comprehensive ablation studies in Tables 3, 4, and 8, incorporating additional layers beyond k=2 yields no further performance gains and introduces redundant noise that degrades overall OOD detection accuracy.
Weakness 4 (Shallow Feature Utilization):
Thank you for raising these important questions regarding the role of shallow features and generalization, which allows us to clarify a fundamental distinction regarding our primary goal. First, ML-AMCoS is a training-free OOD detection framework, not a transfer learning method. We do not fine-tune backbone encoders or transfer pre-trained representations across domains; rather, our objective is to construct a robust OOD detection algorithm that dynamically weights layer-wise feature statistics to operate reliably across diverse settings. Second, regarding residual connections and feature redundancy: while architectures such as ResNet pass low-level signals through skip connections, directly aggregating or concatenating feature tensors at deeper layers causes dominant deep-layer signals to obscure shallow-layer statistical properties (such as the covariance trace and intra-class variance). Instead of merging feature representations directly, ML-AMCoS independently extracts OOD score statistics from each layer and dynamically weights these distinct scoring distributions.