- Rating
- 3
- Clarity
- 2
- Confidence
- 2
- Originality
- 2
- Quality
- 2
- Significance
- 2
Read review
Summary
This paper proposes a pseudo-label construction from p-value spacings that enables calibration assessment in multiple testing without ground-truth labels. It shows isotonic calibration on these pseudo-labels yields a calibrator with vanishing Brier regret, and reveals that q-values can be severely miscalibrated.
Strengths and weaknesses
Strengths:
- The pseudo-label idea is elegant and bridges supervised calibration tools with the unlabeled setting of multiple testing in a principled way.
- The equivalence result unifying isotonic calibration, MLE regression, and the Grenander estimator provides a clean theoretical foundation.
Weakness:
- The theoretical guarantees rely on i.i.d. p-values, but real-world multiple testing scenarios often involve correlated hypotheses; no robustness analysis under dependence is provided.
- The paper only compares against raw p-values and q-values; no comparison with other lfdr estimation methods (e.g., shape-constrained MLE, spline-based approaches) is given.
- Only one simulation setting and one real dataset are used; evaluation on diverse data-generating processes and multiple real-world benchmarks would strengthen the empirical claims.
- Only Brier regret and reliability diagrams are used; standard calibration metrics like ECE are absent, making comparison with the broader calibration literature difficult.
- The regret bound depends only on m (number of hypotheses), not on the per-hypothesis sample size n; the effect of small n on calibration quality is unexplored.
- The paper omits any discussion of computational complexity, which is required by the NeurIPS checklist and matters for large-scale applications.
Questions
See weakness.
Limitations
yes
Paper formatting concerns
None
Final justification
Thank you for the author's response. However, there were too many promises made in the reply. I think that the author could have actually provided more results. Therefore, I will maintain my score.
Meta-review
This paper proposes a framework for interpreting local false discovery rates in large-scale multiple testing as calibrated probabilistic predictions, using pseudo-labels constructed from ordered p-value spacings. The reviewers appreciated the conceptual contribution but raised concerns regarding novelty over existing local FDR methods, limited empirical comparisons, robustness to dependent p-values, and computational aspects. In the rebuttal, the authors addressed these concerns through additional simulations with dependent p-values, experiments on the Platinum Spike dataset, comparisons with established local FDR estimators, and clearer positioning relative to related Xiang et al work. Overall, the rebuttal substantially strengthened the paper, and the reviewers’ major concerns appear to have been largely resolved.