- Rating
- 3
- Clarity
- 2
- Confidence
- 3
- Originality
- 3
- Quality
- 2
- Significance
- 3
Read review
Summary
"Calibeating Prediction-Powered Inference" proposes using the labelled samples to fit a post-hoc calibration function in the prediction powered inference framework, and then constructing a mean estimator by averaging the calibrated predictions over both the labelled and unlabelled set.
Strengths and weaknesses
The main idea of the paper is a good idea, using post-hoc calibration before doing PPI makes sense and there are nice reductions showing that you recover existing estimators with this more general setting.
However, I think a fundamental weakness is that the paper's motivation is the small sample regime (PPI is typically performed because labelled samples are scarce) and every theoretical result in the paper is asymptotical.
I suspect some of the methods introduced in the paper would be very sensitive to overfitting. Typically, isotonic regression is known to overfit a lot with a few hundred samples, which is typically the regime in which PPI would be used (or with even fewer samples?).
While some methods in the paper are probably less sensitive to sample size (linear calibration for example), in my opinion the paper does not explore this regime empirically well enough. More careful finite sample evaluation is needed to support the claims of the paper. Generally I think the "Experiments" section is unclear, the baseline for relative comparisons should be changed, some methods appear to be lacking from some plots, the metrics are not well introduced.
Generally, I think the theoretical claims are a bit mis-leading, suggesting that you can only improve your estimator with post-hoc calibration, which is probably false in practice. From my understanding, Proposition 1 is saying that isotonic regression is calibrated on the samples it was fitted on. This is quite trivial, and does not imply it is calibrated in population, which is what actually matters (Similarly for Proposition 2). The rest of the results are asymptotic, which assumes the post-hoc calibration function are fitted on infinitely many samples. In practice the challenge with post-hoc calibration is avoiding overfitting, since you don't have many samples.
On a more cosmetic note:
- AIPW is used everywhere in the paper while the full wording is only written in the appendix.
- The mathematical notations seem overly complicated.
- What is exactly the relative efficiency you report in your experiments?
Questions
Could you clarify the experiments? I am not convinced that your methods are actually beneficial in the small sample regime for now. What is precisely the relative efficiency you are reporting? I think AIPW or PPI++ should be used as a baseline for relative comparison, since PPI is known to be suboptimal. Also why is PPI++ not reported on Figure 2?
My understanding is that PPI and derivatives can be used for various statistical quantities (not only the mean), is your method restricted to mean estimation? Is this discussed as a limitation somewhere in the paper?
What would change my opinion of the paper is a clear and solid empirical comparison with PPI++ / AIPW, even in small data regimes. It doesn't have to improve upon these baselines everywhere but at least this should be explored and discussed.
I think the paper should frame the theoretical results better, to clarify the setting in which they apply vs the setting of PPI, and discuss the limitations mentioned earlier.
Limitations
I don't think that the risk of overfitting in the small data regime is properly discussed in the paper, while this appears to me as the main limitation, since the motivation behind PPI is this regime.
Same thing for the fact that the paper seems entirely focused on mean estimation, versus other methods that can cover various quantities.
Paper formatting concerns
/
Final justification
While I think the main idea of the paper is elegant, I still believe
(1) there is a mismatch between theoretical results and practical scenarios where the method would be applied.
(2) the paper is often unclear and hard to read.
(3) the empirical evaluation is not thorough / clear enough to convince me of the practical impact of the idea developed in the paper.
(4) some of the limitations in applicability and scope raised by the reviewers are not discussed or fully addressed.
Therefore I will keep my score unchanged.
Small-sample comparison and isotonic overfitting
We agree that our original experiments did not make the small-n tradeoffs easy to assess. We therefore compared the labeled mean, PPI, PPI++, augmented inverse-probability weighting (AIPW), linear calibration, smooth monotone calibration, and isotonic calibration from n=20 to n=1200, including leave-one-out (LOO) versions of linear and isotonic calibration. We used N=16n, the two score settings from our simulation, and 1,000 repetitions per setting.
The table reports RMSE divided by the RMSE of the labeled mean, so values below one are better:
These results do not show uniform dominance, nor do we claim it. They do show that calibration remains useful with very few labels. At n=20, the best calibration RMSE ratios are 0.562 in the mild setting and 0.597 in the strong setting. Under strong distortion, linear, smooth monotone, and isotonic calibration each have lower RMSE than PPI++ at all seven sample sizes.
The concern that isotonic regression may overfit at small n is reasonable, but at n=20, IsoCal's RMSE remains below that of both PPI++ and the labeled mean in both score settings. Its finite-sample weakness is interval coverage: at n=20, the nominal 95% coverage is 0.814--0.871 for IsoCal and 0.905--0.925 for IsoCal-LOO. However, IsoCal-LOO has lower RMSE in only one of the 14 settings. LinearCal-LOO is more favorable, lowering RMSE in all 14 settings, although only by 0.01--1.99. Thus LOO is useful for reducing label reuse and improving coverage, but it is not uniformly better in RMSE.
AIPW, PPI++, and the reported metrics
AIPW and PPI++ were already included in Figure 1. Figure 2 was restricted to the calibration methods. We agree that the layout and changing reference comparisons made this unnecessarily difficult to see, but the baselines were not omitted. To remove the other ambiguity, our empirical relative efficiency is
{\widehat V_{\mathrm{method}}},$$ so values above one favor the method. The values in the table above are RMSE ratios, not relative efficiencies. We agree that the notation and changing reference methods obscured these comparisons; the RMSE ratios above all use the labeled mean as the single reference. ### RePPI comparison We also compared with the mean-estimation version of RePPI using both a random forest and a cross-validated neural network, following its sample-splitting and coefficient-estimation procedure. Across the 14 settings, RePPI-RF has lower RMSE than PPI++ once, while RePPI-MLP-CV does so five times; neither has lower RMSE than MonoSpline. The neural version is unstable at $n=20$, with RMSE ratios $1.450$ and $9.690$; for $n\ge50$, its ratio ranges from $0.576$ to $0.668$. ### What Proposition 1 and the asymptotic theory establish We agree that Proposition 1 establishes empirical, not population, calibration. Its role is to show residual orthogonality and the exact equivalence between our plug-in estimator and an AIPW estimator. It is not the basis for our population claim. The later results establish convergence to the population isotonic projection, asymptotic linearity, and Wald inference. We therefore do not claim that Proposition 1 implies population calibration or finite-sample improvement. More generally, using the same labeled outcomes to fit and evaluate a calibrator can introduce finite-sample bias. For a fixed score, AIPW is exactly unbiased; for our same-sample linear and isotonic fits, our results establish asymptotic linearity without requiring sample splitting. The small-$n$ experiment above is needed precisely because an asymptotic theorem does not settle the finite-sample bias--variance tradeoff. ### Scope: mean estimation and randomized trials We deliberately focus on semisupervised mean estimation, which is the most common use case of PPI. This scope includes mean outcomes within each treatment arm and therefore average treatment effects in randomized trials. We do not consider general M-estimation, and we do not claim that our isotonic results extend unchanged to that setting.