- Rating
- 3
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
The authors propose HyFAD, a diffusion model for filling in missing values in time series. The key idea is that ordinary diffusion models corrupt every frequency band the same way, which ignores that different frequencies carry different kinds of information. HyFAD fixes this with a two-branch design: it adds noise first in the frequency domain, then in the time domain, and reverses that order when denoising. On top of that, it uses a "frequency-aware" step embedding that adapts the reconstruction at each diffusion step based on noise level, what stage of denoising you're in, and how reliable each frequency band is.
Strengths and weaknesses
Strengths
-
Compelling Motivation: Bringing frequency awareness into diffusion makes a lot of sense and well motivated. Standard time-domain diffusion treats all frequency bands uniformly and struggles to recover high-frequency details. Proposing a time-to-frequency denoising trajectory to address this limitation is a logical step forward.
-
Comprehensive Formulation: The underlying math for the dual-domain forward and reverse processes is solid. The authors integrated these cleanly into the DDPM framework, providing explicit, easy to follow step-by-step update rules.
-
Reproducibility: Including a repository that builds on the established CSDI framework is a major plus. It shows transparency and makes it straightforward for others to verify the architectural claims and replicate the results.
Weaknesses
-
Missing concurrent work and unjustified complexity. The paper doesn't discuss or benchmark against a closely related recent work, FSDI (Frequency-Shaped Diffusion for Time-Series Imputation, WWW 2026). FSDI targets the same problem: diffusion models treating all frequency bands uniformly - but solves it through a mathematical reformulation rather than a new architecture: a Parseval-calibrated, per-frequency-bin variance schedule driven by the dataset's spectral energy, with no network changes and no extra parameters. HyFAD, by contrast, leans on a heavy cascaded dual branch design. By the authors own profiling, it trains at 18.06 sec/epoch vs 6.70 sec/epoch for CSDI (2.7x more) and adds inference latency. Given that a parameter-free alternative reaches frequency-aware imputation efficiently, the paper needs to make the case for why this architectural overhead is warranted.
-
Unvalidated theoretical assumptions (Prop. 3.1). The frequency-aware step embedding rests entirely on Prop. 3.1, which assumes a "relative low-pass condition" ( for ). Thats a strong assumption. It holds for some data, but many real world series violate it (e.g. financial data tends to be heavy-tailed, and some physiological signals carry dominant high frequency bursts). The paper offers no empirical check that the assumption actually holds for Physio-net or Air quality, which leaves the generalizability of the embedding in question.
-
Handling of missing data. The method applies the rDFT to perform frequency domain diffusion, but standard frequency transforms assume fully observed, uniformly sampled sequences. Under the extreme missingness in these benchmarks (80–90% on Physio-net), that invites significant spectral leakage. The proposed fix - a "Signal Proxy" blending observed values with the temporal latent , runs into a subtler issue: at early reverse steps (large ), is dominated by high variance Gaussian noise, and feeding that into a global transform could destabilize the spectral representation. An ablation comparing the proxy against simpler alternatives: zero-filling, mean, or linear interpolation before the DFT would help establish that its genuinely the more stable choice.
-
Probabilistic evaluation and baseline rigor. Diffusion models are probabilistic generative models, yet the main evaluation is almost entirely deterministic (DDIM style sampling with only MAE and RMSE). It omits calibration metrics such as CRPS and empirical quantile coverage, which are standard here and used in evaluating comparable methods like CSDI, SSSD, FSDI. It would also help to state explicitly whether the Table 1 baselines were all re-run under the same environment and missingness masks, or compiled from prior publications.
Questions
-
Comparison with FSDI. Given the recently published FSDI, a direct comparison would strengthen the paper. Could you provide one empirically including probabilistic metrics and computational efficiency and clarify what the dual-branch architecture buys over FSDI's zero parameter formulation, since both target the same uniform noise problem?
-
Validating Proposition 3.1. It would help to see a spectral analysis of Physio net and Air quality showing how well they actually satisfy the low-pass assumption behind Prop 3.1. Relatedly, how does the frequency aware embedding behave on a dataset that clearly violates it?
-
Signal Proxy ablation. Could you add an ablation at 90% missingness comparing the Signal Proxy against naive fills such as: mean, linear interpolation, or zeros - applied to the missing indices just before the rDFT? This would isolate whether blending the high variance latent is genuinely beneficial and stable, rather than simply not harmful.
-
Probabilistic metrics. As HyFAD is a generative probabilistic model, reporting CRPS across the benchmarks would round out the evaluation. Its the clearest way to show that the dual domain noise injection improves uncertainty calibration, not just deterministic average error.
-
Baseline sourcing. Could you confirm whether the Table 1 baselines were all re-run in your environment under identical missingness masks, or whether some were taken from prior literature?
Limitations
As mentioned in previous sections
Paper formatting concerns
N/A
Final justification
Thank you to the authors for the thorough rebuttal and the substantial additional experiments. My main concerns have largely been addressed:
FSDI (W1/Q1): The direct comparison and the clarification of what the dual-branch design adds over FSDI's noise-scheduling approach are helpful, and the edge under severe missingness is a fair point. Prop 3.1 (W2/Q2): The spectral analysis of PhysioNet/AQI, plus the non-lowpass synthetic test showing the embedding still works, addresses my concern about the assumption's realism. Signal Proxy (W3/Q3): The 90% ablation against zero/mean/linear fills makes the case that the benefit is real, not just "not harmful." Probabilistic metrics (W4/Q4): The added CRPS results round out the evaluation. Baselines (Q5): Confirmed re-run under identical splits/masks.
Given these clarifications, I'm raising my score.
We thank reviewer 3hD1 for the insightful comments and constructive suggestions. We appreciate the opportunity to clarify the motivation, theoretical analysis, and experimental evaluation of HyFAD. We address the concerns point by point below.
W1&Q1:
We further compare HyFAD with FSDI (WWW 2026), a recent frequency-aware diffusion model for time-series imputation. HyFAD achieves better performance on 7 out of 8 evaluation metrics across different missing rates and datasets. The only exception is MAE on PhysioNet under 10% missingness, where HyFAD obtains a slightly worse result.
We further clarify the difference between HyFAD and FSDI. FSDI addresses the frequency-insensitive noise perturbation problem by introducing a frequency-dependent variance schedule, i.e., adjusting the amount of noise injected into different frequency components during the forward diffusion process. In contrast, HyFAD focuses on the frequency-aware denoising trajectory by explicitly modeling how temporal and spectral information interact during reconstruction.
Specifically, HyFAD introduces a coupled time-frequency diffusion framework, a mirrored time-to-frequency reverse denoising process, and a frequency-aware diffusion embedding to provide stage-dependent spectral guidance. Therefore, FSDI mainly answers "how much noise should be assigned to each frequency component?", whereas HyFAD addresses "how should different frequency components be progressively reconstructed throughout the denoising process?".
Although HyFAD introduces additional computational overhead due to explicit time-frequency interaction modeling, this design enables adaptive frequency reconstruction beyond static frequency-dependent noise scheduling. Notably, the improvements become more evident under severe missingness (e.g., 90% missing rate), where recovering frequency details requires not only frequency-aware perturbation control but also effective modeling of the reconstruction trajectory. These results demonstrate that the additional architectural complexity of HyFAD provides meaningful benefits for challenging imputation scenarios.
W2&Q2: To examine whether the relative low-pass condition assumed in Proposition 3.1 is representative of the benchmark datasets, we perform spectral analysis on PhysioNet and Air Quality using the original sequences without applying artificial missing masks. We compute FFT power spectra after removing the DC component and divide frequencies into low (0,0.1], middle (0.1,0.3], and high (0.3,0.5] bands. Native missing entries are temporarily filled only to obtain regularly sampled sequences for FFT computation, and these filled values are not used for model training or evaluation.
The results are summarized below. Both datasets exhibit strong low-frequency dominance: the low-frequency energy consistently exceeds middle- and high-frequency energy, and the majority of samples satisfy E_{\mathrm{low}}\ge E_{\mathrm{mid}}\ge E_{\mathrm{high}}. The normalized PSDs also show a decreasing trend as frequency increases. These results do not prove Proposition 3.1, but indicate that its relative low-pass condition well characterizes the spectral properties of the benchmark datasets and supports the motivation of our stage-aware frequency scheduling.
Besides, the proposed frequency-aware embedding does not enforce a fixed low-to-high reconstruction order. Instead, it combines stage-aware scheduling with data-dependent spectral gating and missing-aware reliability:
g(t)=g(t)⊙S(t)⊙R.
Therefore, when the signal distribution violates the low-pass condition, the noise-aware frequency gate can adapt the frequency emphasis according to the actual spectral energy distribution, rather than blindly following the low-frequency-first prior.
To evaluate this behavior, we construct a synthetic non-lowpass dataset where high-frequency components dominate the signal energy (E_{high}>E_{low), violating the condition in Proposition 3.1. Under 90% random missingness, HyFAD remains effective and substantially outperforms CSDI:
HyFAD reduces overall RMSE by 45.7% and high-frequency reconstruction error by 47.9% compared with CSDI. This demonstrates that the effectiveness of HyFAD does not depend on the relative low-pass condition as a strict data constraint; instead, the frequency-aware embedding provides adaptive guidance and remains effective under diverse spectral characteristics.
W3&Q3:
We clarify that the Signal Proxy in HyFAD is not a static missing-value filling strategy, but a diffusion-synchronized spectral reference that evolves with the denoising trajectory. Unlike fixed filling methods (e.g., zero filling, mean filling, or linear interpolation), which construct a completed sequence once before applying rDFT and remain unchanged throughout diffusion, the Signal Proxy in Eq. (21) dynamically updates missing regions using the current diffusion state while preserving the observed values.
This design enables the frequency modeling module to progressively incorporate reconstructed latent information as the denoising process becomes more reliable, while maintaining the observed signal as a stable spectral anchor in early reverse steps. Therefore, the frequency representation is less affected by the spectral distortion caused by arbitrary fixed completion strategies, especially under extreme missingness.
Furthermore, HyFAD incorporates missing-aware Band Reliability (Eq. 18) in the frequency-aware diffusion embedding, which explicitly adjusts the contribution of different frequency bands according to their reliability under missing patterns. Therefore, HyFAD does not directly rely on unreliable latent spectra, but combines the dynamic Signal Proxy with band reliability to achieve robust frequency modeling.
To further verify the effectiveness of the Signal Proxy, we add an ablation study under 90% missingness comparing it with several fixed filling strategies, including zero filling, mean filling, and linear interpolation before rDFT. The results demonstrate that the proposed dynamic Signal Proxy consistently improves imputation performance, validating that the benefit comes from diffusion-synchronized spectral modeling rather than simply avoiding degradation from fixed filling strategies. The ablation results show that the proposed Signal Proxy consistently performs best under 90% missingness, achieving the lowest MAE (0.448) and RMSE (0.782) among all compared strategies. Compared with linear interpolation, mean filling, and zero filling, the improvements are especially clearer in RMSE, which indicates that the Signal Proxy better suppresses large reconstruction errors and provides a more stable spectral reference under severe missingness. If the proxy were merely “not harmful,” its performance would be similar to these naive fills; instead, it consistently improves over all of them. This supports our claim that the benefit comes from diffusion-synchronized spectral modeling rather than from simply replacing missing values with a fixed heuristic before rDFT.
W4&Q4:
Since our current evaluation adopts DDIM sampling, which produces deterministic predictions, we additionally perform experiments with DDPM sampling to provide probabilistic forecasts and evaluate probabilistic metrics. These experiments are currently underway due to the limited rebuttal timeline, and we will update the results as soon as possible.
Q5: All baseline results in Table 1 were re-implemented and re-run in our experimental environment. All methods were evaluated using the same data splits, missing mask generation strategy, and evaluation metrics for fair comparison.
We hope these clarifications and additional experiments address the reviewer’s concerns. We would be happy to further discuss any remaining questions.