Computational molecular property prediction requires representations that capture local chemistry, long-range interactions, and molecular topology. Conventional fingerprints provide efficient local substructure features, whereas learned graph and sequence models can represent broader context but often rely on pretraining or three-dimensional conformers. We introduce Wide Encoded Extended Connectivity Fingerprints (WEECFP) with Substructure Rotary Graph-distance Encoding (SuRGE), a tokenized hierarchical Morgan representation in which graph-distance-dependent rotations are applied at the input and within transformer self-attention. Across MoleculeNet and the Therapeutic Data Commons ADMET benchmarks, WEECFP-SuRGE is competitive with recent pretrained and geometry-aware methods without external pretraining or conformer generation. We also show that the rotated token representation remains structurally informative. A guided confirmed-handshake overlap procedure reconstructs the correct constitutional isomer for 92.6% of a 4,200-molecule self-library evaluation. Together, the predictive and reconstruction results indicate that WEECFP-SuRGE preserves local substructure identity while making relative topology available to the model.
We thank the reviewer for their consideration of the manuscript and hope that the revised version provides a clearer representation of the presented algorithm. Specifically, we do not intend to present the WEECFP fingerprint method and the associated transformer as the sole contribution of the work. Instead, WEECFP is intended to enable the application of SuRGE, which adds graph-distance information in a format similar to RoPE, and secondarily supports library-free reconstruction in the evaluated settings. Additionally, we would like to point out the use of anchor reference distance encoding of SuRGE in the attention layer as a scalable surrogate for pairwise graph distance (Section 3.2). With respect to the reviewer’s comment on the missing variable definitions, we thank the reviewer for noting this discrepancy and have made corrections throughout the manuscript to make the methods clearer. Section 3.1 now summarizes the token construction, and SI Section K specifies the digest bytes, coordinate indices, and signed updates, with each symbol defined. With respect to the reviewer’s comment on the selection of engineering choices in both the fingerprint construction and model design, we have added further discussion throughout the manuscript to specify the design motivations. Additionally, we have incorporated ablation studies shown in Section 5.4 and Table S14 (SI Section J). These indicate that most engineering choices outside SuRGE have little effect on predictive performance: the token-content, transformer-size, and fingerprint-constant variants shift RMSE by a few percent, and 45 of the 224 comparisons reach p<0.05 without adjustment, against roughly 11 expected by chance. Removing SuRGE, by contrast, is consequential on particular targets (16.6% on FreeSolv and 111.1% and 174.0% on QM9 α and C_v, against under 3% on Lipophilicity and QM9 μ).