The paper addresses an important and timely problem: open medical VLMs are limited both by the scale of available medical image-text data and by the post-training method used to elicit domain knowledge. The proposed recipe is simple and compelling: scale medical multimodal pre-training using a large PubMed-derived corpus, then use RL over caption-derived verifiable and rubric rewards to activate the learned medical visual knowledge. The dataset scale is a meaningful contribution, and the paper provides substantial appendix detail about data filtering, prompt construction, rubric validation, and physician preference evaluation.
The empirical results are strong. In Table 2, pre-training plus RL improves Qwen3-VL-8B-Instruct by +9.9 average points and Qwen3-VL-32B-Instruct by +10.1 average points across eight medical multimodal benchmarks. The ablations are useful: RL alone gives smaller gains, while pre-training plus SFT gives much smaller gains and even degrades the 32B model average. This supports the paper's claim that domain pre-training and RL are complementary. The paper also evaluates open-ended response quality through MedMM-ExpertRubric and a physician preference study, which is important because medical VLM usefulness is not captured by multiple-choice accuracy alone.
The main weakness is that the strongest causal claim, that RL is better than SFT for eliciting pre-trained medical visual knowledge, is not fully isolated. The SFT baseline uses answers generated by Qwen3-VL-32B-Instruct on the same prompts used for RL. This controls prompt set and data volume, but the comparison may still be confounded by teacher quality and target-answer quality. A much stronger teacher such as Gemini-3-Pro or GPT-5.4 might produce better SFT targets and narrow the gap. Without such an ablation, the evidence supports "this specific RL setup is better than this specific SFT setup" more strongly than it supports "RL generally elicits pre-trained medical visual knowledge better than SFT".
Another weakness is reproducibility and cost. GPT-5.4 is used for seed labels, question generation, validation, and rubric generation; GPT-4.1 is used for rubric judging and to generate 1M labels for a learned reward scorer. The paper appropriately trains a smaller VLM scorer because online GPT-4.1 reward evaluation would be expensive, but it does not report the number of GPT-4.1/GPT-5.4 calls, cost, wall-clock overhead, or detailed validation of the learned scorer beyond 91.5% agreement with GPT-4.1. Since the data and reward pipeline is central to the contribution, these details matter.
The dataset construction pipeline is promising but would benefit from more quantitative validation. The appendix explains the VLM-based quality checks and task-specific classifier heads, but I did not find a physician-reviewed gold-standard subset for PubMedVision-Plus-Core itself, nor precision/recall or modality-specific quality estimates for filtering. Because the dataset is a core contribution, a small human-reviewed quality audit would substantially strengthen the paper.
Finally, the evaluation is strong for medical VQA and PubMed-style figure understanding, but the paper would be more convincing with a small clinical report-style transfer evaluation. The authors acknowledge that PubMed figures differ from real clinical workflows. A quick evaluation on a chest X-ray report generation or clinical radiology task, for example using MIMIC-CXR, IU-Xray, CheXpert Plus, ReXGradient, or ReXVQA if feasible, would help test whether the gains transfer beyond PubMed figure QA. Please have a look at the leaderboards at https://rexrank.ai/ for more details.
Strengths
The scale of PubMedVision-Plus and PubMedVision-Plus-Core is substantial, and the paper gives a relatively transparent filtering pipeline with useful prompts and examples in the appendix.
The pre-training plus RL recipe is simple and well motivated. Table 2 and Figure 1 provide coherent evidence that pre-training raises the ceiling for medical visual capability and that RL elicits more of that capability than the reported SFT baseline.
The paper evaluates both closed-form benchmark accuracy and open-ended medical answer quality, including physician-filtered rubrics and physician preference judgments.
The authors take some care with contamination and general-capability preservation: they filter PMC-VQA by PMCID, mix general-domain tokens during pre-training, mix RubricHub examples during RL, and report general capability results in Table 3.
Weaknesses
The SFT baseline is not strong enough to fully support a broad conclusion that SFT generally fails to elicit pre-trained medical visual knowledge. A stronger-teacher SFT baseline is needed.
The paper lacks statistical uncertainty for the main benchmark results. Even if repeated training runs are too expensive, bootstrap confidence intervals over evaluation examples should be feasible.
The learned reward scorer is not sufficiently characterized. Reporting only 91.5% agreement with GPT-4.1 leaves open questions about calibration, clinically important failure modes, positive vs. negative rubric items, and modality-specific reliability.
The dataset filtering pipeline lacks a clear human gold-standard validation set for PubMedVision-Plus-Core. The appendix describes how filters are trained, but not enough quantitative evidence that the retained 12M pairs meet the intended quality standard across modalities.
Some implementation details are underexplained in the main paper, including sequence packing and masking during pre-training, the meaning of "seed data" and "task-specific heads", and the naming relationship between HuatuoGPT-Vision-7B and the proposed HuatuoGPT-5 models (why do they share the same prefix?).
The manuscript has minor presentation issues, including typographical errors in Figure 2 and missing or non-local citations for some Table 2 baselines.
Meta-review
Summary. HuatuoGPT-5 is a medical vision-language model built by large-scale medical multimodal pre-training followed directly by reinforcement learning. Figure-caption pairs from 15.2M PubMed papers form PubMedVision-Plus (~60M pairs), filtered in three stages to a 12M-pair subset, PubMedVision-Plus-Core. PubMedVision-RL is synthesized from the same corpus: multiple-choice items with verifiable rewards plus open-ended items with rubric rewards, scored by a distilled scorer at 91.5% agreement with GPT-4.1. Qwen3-VL backbones at 8B and 32B are continued-pretrained then trained with GRPO. Across eight medical benchmarks the paper reports average gains of +9.9 (8B) and +10.1 (32B) with general capability preserved, plus a new rubric benchmark, MedMM-ExpertRubric, and a physician preference study.
Strengths. All three reviewers credit the data contribution: PubMedVision-Plus and -Core are called valuable for the community, a meaningful contribution with a transparent filtering pipeline, and a significant open data contribution. Two reviewers credit the evaluation breadth, including general-capability preservation and rubric and physician-preference evaluation beyond multiple-choice accuracy; one adds that the results are strong, the ablations useful and the contamination and general-capability handling careful. The Figure 1 pilot design, gains on non-PubMed benchmarks, and the reward-complementarity analysis are also credited.
Weaknesses.
Questions to address in the author response.
The panel is unanimously positive and this submission is heading toward acceptance after solving reviewers concerns.