- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 2
- Significance
- 3
Read review
Summary
This work challenges the current assumption, and particularly the work of Feldman and Zhang, that generalization requires memorization to emerge. The paper identifies four structural experimental flaws in Feldman and Zhang's original work that undermine the underlying claim that memorization is a necessary condition for generalization. Precisely, the paper focuses on (i) the high approximation error introduced by approximating leave-one-out tests, necessary to marginalize in and out probabilities across models that do and do not contain a specific sample in their training data; (ii) the definition and formulation of memorization, which, according to the authors, leads to high false-positive rate; (iii) the unprincipled thresholding, used to discriminate memorized from non-memorized samples; and (iv) train-test data leakages, which would conflate the "memorization as requirement for generalization" claim. The paper then proposes four practical fixes to the aforementioned issues, showing discordant outcomes with the original work of Feldman and Zhang.
Strengths and weaknesses
Strengths
Overall, I think this work challenges a clear and relevant assumption in the community, i.e., that generalization does not require memorization. The paper is well written, easy to follow, and makes effective use of figures to convey its central argument. Finally, the limitations of prior work are well motivated and clearly articulated.
Major Weaknesses
-
Inconsistent results: I found lots of inconsistencies in the presented results, which, considering this is an empirical work, it greatly lowers my overall confidence in the drawn conclusion. This is exacerbated by the exceptionally high bar of the negative results type of contribution. Below are the inconsistencies I found:
1.1 Suspiciously low ImageNet accuracy: Table 3 reports the per-dataset per-model accuracies after removing memorized samples and randomly memorized samples. However, ImageNet accuracies are suspiciously low. Considering that a ResNet-50 achieves >70% on ImageNet, seeing an accuracy of 13.2% after removing 36% of samples is unrealistic, especially since this happens for both memorized and random sample removal.
1.2 Figure 5 and Table 1 mismatch: Figure 5 shows that, for ResNet-50, the accuracy difference after removing memorized and random samples is positive for C100 and ImageNet, while it slightly decreases (statistically insignificant) for C10. Instead, Table 1 shows a decrease also for ImageNet, which, according to Sec. 5.1, reports results for ResNet-50.
1.3 Wrong in Table 1: The "+ 0.95 Sampling Rate" entry for the ImageNet dataset in Table 1 reports a of 3.58, while it should be 2.31.
-
Under specified experimental steps: While reading the paper, I felt some details are left unaddressed, and I believe they undermine the reproducibility and the overall confidence about the claims made in the paper. A simple example is the "Score" and "" reported in Table 1, which are not defined anywhere in the paper. From my understanding, they respectively report the Accuracy difference between removing memorized and random samples, and the Score gap with Feldman and Zhang's work. Another example is the "paired t-test across multiple training runs" to "assess statistical reliability". Yet, the paper does not provide sufficient details to reproduce this experiment.
-
Proposed solutions are not backed by empirical findings or theoretical results:
3.1 Improved sampling bias: The first limitation raised by this work is that a low sampling rate induces sampling bias. To this end, the authors criticize the prior work's sampling rate () of 0.7, noting that it results in "substantial approximation error." Yet, Figure 1 shows that for C10 and C100, the approximation error is rather stable in the interval [0.7, 0.9], and even though it is not in ImageNet, it's always lower than the other two investigated datasets. Still, Table 1 shows it as one of the two proposed improvements that better support the author's thesis. Thus, this makes me question the overall reliability of this result, which seems too brittle to draw conclusions from.
3.2 Fractional difference: I am unsure whether the proposed fractional difference-based memorization score is a better measure than what was previously proposed in prior work: (i) I do not agree with the authors in saying that a drop from 25% accuracy to 0% is different from a drop from 100% to 75%. I think this assumption is (partly) neglecting the frequency of each subpopulation, promoting the selection of hard, noisy, or mislabeled datapoints rather than valid rare subpopulation examples. (ii) The experiment with randomly labeled datapoints does not confirm the superiority of the fractional difference as a metric. Rather, I believe it is mostly confirming that fractional difference can target noisy/mislabeled samples. The point is that this experiment is treating genuine memorization of natural examples as false positives.
3.3 Principled thresholding: As per the previous issue (3.2), I think thresholding based on the 95th percentile memorization of randomly labeled samples is just focusing memorization on noisy or mislabeled datapoints. Furthermore, I feel the distribution of randomly memorized samples is not the null distribution. The null distribution would be the distribution of memorization scores in case no memorization is happening.
Finally, I believe that the increase in accuracy obtained by removing "memorized" samples from the proposed approach is because the authors are actually removing mislabeled or noisy samples.
Minor Weaknesses
- Extra "a" in L.158
- Extra "might not" in L.165
- "an" -> "in" in L.167
- Fig. 8 caption and plot titles are not sufficiently informative
- Fig. 11 is missing the legend
- Extra "in" in L.358
- Sec. 3.3 states that "Unfortunately Feldman and Zhang [12] do not provide any threshold on how to differentiate memorized points from non-memorized ones." This is false, as they report a threshold of 0.25 and the authors actually use it later in the paper. So the statement should be converted to "Feldman and Zhang [12] use a threshold of 0.25."
- Sampling rates of Fig. 1 do not include the 0.95 rate used in the rest of the paper. It should be shown for comparison.
Questions
-
Clarifying inconsistencies: Could the authors clarify the apparent inconsistencies raised above and explain how they affect the paper’s main claims?
-
Characterization of removed data points: Could the authors provide evidence that the removed data points are not just mislabeled/noisy exemplars?
-
Evidence supporting the proposed solutions: Could the authors provide stronger empirical or theoretical support for the proposed solutions? In particular:
3.1 Improved sampling bias: Could the authors clarify the apparent discrepancy between the approximation error shown in Fig. 1 and the results reported in Table 1?
3.2 Fractional differences: Could the authors provide empirical evidence or theoretical justification for using the proposed fractional-difference score instead of a simple difference score?
3.3 Sensitivity to threshold values: Could the authors report the method’s performance across a range of threshold values, similar to the analysis shown in Fig. 2 of Feldman and Zhang?
While I believe that the raised concerns for the work of Feldman and Zhang are genuine, I do not believe that the proposed solutions and the corresponding findings are sufficient to support the thesis that generalization does not require memorization.
Limitations
The authors did not discuss the limitations of their work. I suggest the authors take a look at the major weaknesses I raised, as I believe they are, at least some of, the current limitations of this work.
Paper formatting concerns
I am not sure it is a major concern, but the paper presents the checklist before the Appendix section, and the authors forgot to remove the header of the checklist.
Final justification
While I initially assigned a negative score to this paper, the evidence provided by the authors is quite compelling, which made me change (positively) the overall assessment of this paper. Therefore, I strongly advise the authors include the discussed details in the manuscript.
Nonetheless, I decided to assign this paper a score of 4 since it lacks supporting theory for the memorization measurement used.
Could the authors clarify the apparent inconsistencies raised above and explain how they affect the paper’s main claims?
Thank you for pointing out these inconsistencies. The reviewer is correct: these were mistakes on our end, and we have corrected them in the revised manuscript. Importantly, these corrections strengthen the empirical evidence supporting our conclusions.
First, regarding the low ImageNet accuracy, we found that the final accuracy had been underreported. We have updated the paper to reflect the corrected values. We find that the core result becomes stronger: on ImageNet, removing the memorized points identified by our method yields an even larger positive impact on accuracy than originally reported.
Second, regarding the mismatch between Figure 5 and Table 1, the reviewer is absolutely right. We identified the source of the discrepancy and have corrected the figure.
Third, regarding the incorrect delta computation in Table 1, we have adopted the reviewer’s suggested computation of using the delta difference between FZ and ablation. Interestingly, the new metric reveals a consistent trend across nearly all experiments, from weakest to strongest ablation: the fractional-difference criterion contributes the least, increasing the sampling rate to 0.95 0.95 provides a moderate gain, principled thresholding gives a stronger correction, and test-set de-duplication contributes the largest overall improvement. We have revised the text accordingly to accurately describe these corrected results.
Characterization of removed data points: Could the authors provide evidence that the removed data points are not just mislabeled/noisy exemplars?
We rely on prior work that identifies approximately 4,500 potentially mislabeled examples in CIFAR-10 [1]. This is likely a conservative upper bound on the amount of label noise, since other studies have estimated the CIFAR-10 label-error rate to be closer to 0.5% [2]. Even under the more expansive estimate from [1], we find that among the approximately 750 memorized points removed by our method, only 177 are marked as mislabeled. This corresponds to roughly 24% of the removed set.
This result suggests that the majority of removed points are not simply mislabeled examples. Instead, roughly 76% of the removed points are not identified as mislabeled by this prior annotation source. Thus, while mislabeled or noisy examples do constitute a meaningful subset of the memorized points, they do not fully explain the behavior captured by our method.
Could the authors clarify the apparent discrepancy between the approximation error shown in Fig. 1 and the results reported in Table 1?
Thank you for raising this point. We agree that the relationship between the approximation error in Fig. 1 and the downstream utility results in Table 1 should be clarified.
Although the differences in approximation error shown in Fig. 1 may appear small in absolute terms, Table 1 shows that these differences have a measurable and non-negligible impact on downstream utility. Across all three datasets, increasing the sampling rate leads to a positive Δ, indicating that the marginal utility improves relative to the FZ baseline. These improvements are also statistically significant, suggesting that the reduction in approximation error translates into meaningful empirical gains.
We agree that the largest effect is observed on ImageNet. However, this does not imply that the effect is absent on CIFAR-10 or CIFAR-100. Rather, the impact is smaller on these datasets, which is consistent with their lower complexity. As shown in Fig. 1, approximation error increases with dataset complexity, and therefore improvements in the sampling procedure are expected to have a larger effect on more complex datasets real-world datasets.
Sensitivity to threshold values: Could the authors report the method’s performance across a range of threshold values, similar to the analysis shown in Fig. 2 of Feldman and Zhang?
Thank you for this suggestion. The impact of lower thresholds can be understood by studying Table 1. The De-duplication shows the drop in accuracy when a threshold of 0.25 is used (to mimic FZ) but the test set is deduplicated to remove identical samples. Yet, we see that there is a significant improvement in accuracy over FZ. This implies that we when combine the remaining ablations at 0.25 threshold, we can expect the same, if not greater increase, improvement in accuracy (as we see in the final row of table 1).
[1] "Learning with Noisy Labels Revisited: A Study Using Real-World Human Annotations" accepted by ICLR2022.
[2] https://github.com/cleanlab/label-errors