- Rating
- 5
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper addresses three intertwined challenges commonly encountered in existing virtual staining methods: Weakly-paired data, Patch-wise isolation, and Reassembled-region quality degradation, identifies context contamination as the root cause of these issues, and proposes a solution named SheafStain from the perspective of sheaf theory. Extensive experimental validations are conducted in this work, with both quantitative and qualitative comparative experimental results provided to demonstrate that SheafStain can effectively resolve the aforementioned problems.
Strengths and weaknesses
Strengths:
- The paper is clearly written with a reasonable structure and detailed experimental descriptions.
- Sufficient experimental evaluation metrics are adopted from diverse perspectives, and the proposed method achieves a considerable performance improvement.
- Although SheafStain is a combination of existing theories and technologies, it is technically reasonable to apply sheaf theory to address various problems existing in patch stitching.
- The discussion of limitations and future work is rational.
Weaknesses:
- The rationale for selecting the baselines is unclear.
- The reasons for hyperparameter selection are not elaborated.
Questions
- Do the three issues summarized in Figure 1 overlap? In particular, both stain-tone drift and chromatin-distribution mismatch lead to patch-boundary discontinuities.
- The meaning of the bolded rows in Table 1 is unclear; it is recommended to add a description of the bolded rows in the caption.
- Is the ground truth (GT) of the first sample of MIST in Figure 4 an incorrect image? It does not seem to match the corresponding H&E image. In addition, although the visualization demonstrates that SheafStain can eliminate artifacts such as stitching seams, a close inspection reveals certain discrepancies between its outputs and the ground truth. Therefore, how reliable are the images generated by SheafStain?
- Although hyperparameter settings are provided in Appendix E, what are the rationales for selecting these parameter values? How do different parameter configurations affect model performance?
Limitations
yes
Paper formatting concerns
None
Final justification
During the Rebuttal stage, the author provided detailed responses to my concerns and supplemented relevant parameter experiments and reasons for parameter settings. The author promised to include these details in the final version. Additionally, I also reviewed the comments of other reviewers and the corresponding responses from the author. Their comments were all reasonable, and there were some aspects that I had not paid attention to, such as low method efficiency and dense concepts.
Overall, this paper has a very good research motivation. Using the Sheaf theory to solve the numerous problems existing in patch stitching is reasonable. The experimental evaluation perspective is diverse, the indicators are sufficient, and the effect improvement is quite significant.
Making minor modifications to the final version based on the reviewers' suggestions also helps to improve the quality of the manuscript.
Thank you for the close and specific questions. We answer all six points below and state the change we will make in each case.
W1. Rationale for the baseline selection.
You are right that the paper names the six methods without saying why those six. The set follows the architectural families in our related work, one representative from each, plus our own backbone as a control.
pix2pix and CycleGAN are the paired and unpaired GAN pipelines that established cross-stain translation, and most prior work in this area carries them as benchmark models. PSPStain is the pathology-specific GAN designed for H&E to IHC. D-VST is the diffusion transformer line. UNIStainNet is the foundation-model-guided line, and it is the closest prior work to ours because it also conditions on a pathology VFM. UNSB is the Schrödinger Bridge backbone we build on, so it isolates what our components add.
Two further conditions applied. Each method must release source code, since we retrain all of them rather than reuse published results. Published numbers on these datasets come from a different patch size and a different evaluation protocol, so they would not sit on the same scale as ours. Apart from the backbone, each is also one this literature already benchmarks against, whether as a published H&E to IHC method or as the general translation baseline that the BCI and MIST papers themselves include. CC-WSI-Net, which another reviewer raised, targets patch stitching and would have fit the set well, but it does not release code. The paper states that we retrain from publicly available source code, but it does not give the reasoning above. We will add it to the experimental setup, together with the methods we considered and could not include.
W2 and Q4. Rationale for the hyperparameter values, and the effect of different configurations.
The paper lists seven loss weights, and they were not all set in the same way.
λSB, λNCE and λsheaf are all 1 and none of them was varied in any run. The UNSB paper sets its bridge weight to 1, and the UNSB baseline in Table 1 is trained with the same weights we use, so the ablation adds our components without changing the backbone weighting. λsheaf is fixed at 1 by construction, since the sheaf term is the objective the paper is about and therefore carries the unit scale that the auxiliary weights are expressed against.
λstain-align is 1 whenever the term is active. What we set for it is a schedule rather than a magnitude, since the term is off for epochs 1 to 350 and on for the last 50 of 400.
That leaves the auxiliary weights, which we set by a coarse grid over {0.1,0.5,1.0}, one order of magnitude apart. The search ran in two stages: a component ablation to decide which terms belong in the objective at all, which is Table 1, and then the weight grid. One setting is used everywhere in the paper. BCI and all four MIST markers share it with no per-dataset retuning.
On how configurations affect performance, the axis with the largest effect is the pixel sheaf balance α. With α=1, all 8 settings land in a narrow band, FID 43.7 to 54.8. With α below 1, only 7 of 18 settings reach that band and the worst reaches FID 164. Inside the α=1 region the remaining weights move the result much less. The 26 settings below vary the cocycle, Fourier and α weights with the DAB weight held at 0.1, and each row reports the per-metric value across those settings rather than one configuration. The grid runs use a shortened 100-epoch schedule for screening, so these values are not the ones the paper reports. The same setting trained for the full 400 epochs reaches FID 36.36 on this block.
The selected setting is second of 26 on mean rank over these four metrics and it is not the best on any of them. It is the best on DISTS among the α=1 settings, and its gap to the grid best is 0.4% on DISTS and 0.9% on LPIPS, inside the range where settings are not distinguishable. The cocycle weight of 0.1 has the lowest mean FID of its three values, 54.8 against 71.9 and 71.5. We read this as the outcome depending on the structure of the objective and on α, rather than on a precise weighting of the auxiliary terms. We will add the grid, the two-stage procedure, and this reading to the hyperparameter appendix.
Q1. Do the three issues in Figure 1 overlap?
They do, and you are right that stain-tone drift and chromatin-distribution mismatch both surface at patch boundaries. The three are not independent failure modes, and the paper does treat them as one cause with three manifestations. The Figure 1 caption states that independent patch translation induces all three, and Section 1 describes how inter-patch inconsistencies translate directly into stitching artifacts and tone discontinuities in the reassembled region.
What separates them is where they act and what responds to them. Tone drift is a property of a whole patch relative to its neighbors, and it shifts the chromogen readout that biomarker scoring depends on. Chromatin mismatch is a within-patch texture property that changes nuclear appearance. Boundary discontinuity is the geometric signature at the seam, and it is what the Tiling Score measures. A method can reduce the seam and leave the tone wrong, which is why we report them separately.
The caption carries the shared cause in a single word, induces, which is easy to read past. We will make it explicit that (a), (b) and (c) are three ways one failure becomes visible, and name the metric that responds to each.
Q2. Meaning of the bolded rows in Table 1.
Bold in Table 1 marks the final row, which is the complete model, and it does not mark the best value in a column. Table 3 uses bold for the best value. Carrying two meanings on one form of emphasis without saying so is a defect on our side, and the caption should have stated the convention.
We will make Table 1 follow Table 3, so that bold marks the best value in each column and the complete model is identified by its row label instead. Under that convention the final row is best on FID, LPIPS, DISTS and DAB-r, while KID is best at the DAB intensity step and Tiling Score at the pixel sheaf step. The paper already says as much in the text, where we note that TS plateaus after the pixel sheaf loss.
One point about the DAB-r column. A transpose in our color deconvolution meant that column was computed on the wrong stain channel, and the corrected values appear in our response to Reviewer 1. The ordering within the column does not change, so the statement above holds either way.
Q3. The MIST ground truth in Figure 4, and how reliable the outputs are.
On the pair. That row is
4M2103059_22_9.jpg, which appears under the same filename in theval_HEand theval_IHCfolder of the MIST HER2 release [A], so it is the pair the dataset itself provides, and the tissue structure agrees between the two. What differs is the color. That field carries almost no chromogen, with strong DAB covering 7.9% of its area, so the IHC image is dominated by a light counterstain while the H&E image is strongly eosinophilic. Side by side the two look unrelated even though they show the same tissue. MIST pairs are also cut from consecutive sections, so they are neighboring slices rather than one physical plane. We will note both points in the caption.On reliability. Exact agreement with the reference is not the right target here, for the reason just given. The reference is a different physical section, so a pixel-level match is not attainable by any method. We therefore test whether the outputs carry the biological signal, with a protocol that does not depend on appearance. We train a HER2 Low/High classifier on translated outputs alone and evaluate it on real IHC from the BCI test set (Table 2).
Features that are artifacts of a generator do not transfer to real IHC, while features that encode HER2 grade do, whatever the texture statistics of the synthetic images look like. Under this protocol SheafStain is ahead on all three measures, and its margin over UNIStainNet is 4.2 points of accuracy and 0.057 AUROC. That is the level at which we claim the outputs are usable, and we will make that scope explicit in the paper.
References
[A] F. Li, Z. Hu, W. Chen, and A. Kak. Adaptive supervised PatchNCE loss for learning H&E-to-IHC stain translation with inconsistent groundtruth image pairs. MICCAI, 2023.