- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper studies a systematic bias in the minibatch estimator of the drifting field used to train drifting models (Deng et al.), a recent class of one-step generative models. The drifting field combines attractive and repulsive softmax-weighted centroids over data and generator distributions. Because computing these centroids over the full distribution is intractable, standard practice replaces them with minibatch empirical estimates. The authors identify that this minibatch centroid (with softmax weights ) is a self-normalized importance-sampling (SNIS) / ratio-of-means estimator of the true target centroid , and is therefore structurally biased.
The authors make four contributions. First, they derive an exact bias expression for : (Theorem 3.1), and characterize two zero-bias conditions (Theorem 3.2). Second, they derive the leading-order bias for general via the multivariate delta method: (Theorem 3.3). Third, they propose Analytical Bias Correction (ABC), a closed-form plug-in correction (Eq. 7–8) that reduces bias from to (Theorem 4.1), preserves convex-hull containment of the corrected centroid (Proposition 4.2), and introduces no first-order variance increase (Proposition 4.3). Fourth, they show that temperature tuning cannot substitute for bias correction (Appendix D). The correction requires only two additional lines of PyTorch code with negligible wall-time and memory overhead.
Empirically, a 2D Gaussian toy confirms the theoretical and scaling. CIFAR-10/100 experiments with a 26.6M DriftDiT-Small architecture show FID improvements that are most pronounced at small per-class sample counts .
Strengths and weaknesses
Strengths
- All central theoretical results were independently verified by re-derivation. Theorems 3.1, 3.3, and the ABC formula (Eq. 7–8) are mathematically correct. Appendix proofs (good-event splitting, Hoeffding tail control, fourth-order Taylor remainder bounds) are rigorous.
- The paper presents a coherent three-part guarantee: bias reduction to (Thm 4.1), convex-hull containment of the corrected centroid (Prop 4.2), and no first-order variance increase (Prop 4.3).
- The convex-hull containment result (Prop 4.2) is the most distinctive and non-obvious property, ensuring the corrected centroid does not escape the data manifold, a practically important geometric constraint.
- The correction is genuinely free to deploy: two lines of PyTorch, compute (same order as baseline), with minimal extra GPU memory, and time within noise.
- Appendix D (temperature cannot substitute for bias correction) is quite a nice result with a clean two-condition argument and effective-sample-size cost analysis.
- The connection to classical SNIS/ratio-estimator literature (Beale, Tin, Hesterberg, Owen) and to concurrent work (Lai et al.) is acknowledged.
- The authors provide a full set of hyperparameters (Table 6) used.
Weaknesses
- Gap between the toy bias experiment and the CIFAR FID claims. Figure 2 shows that ABC and Standard bias curves nearly overlap at small (4, 8), meaning ABC barely reduces bias precisely where Table 1 claims the largest FID gains. The main finding "largest gains at small " is not explained and is arguably contradicted by the paper's own theory. Plausible alternative explanations for the small- CIFAR gains (variance/shrinkage regularization from the factor, optimization–temperature interaction, seed noise) are not ruled out. This is the single most important gap in the paper.
- Statistically underpowered empirical claims. At , ABC is actually worse on best FID (3.40±0.08 vs. 3.24±0.03). Several reported improvements have overlapping ranges. No significance testing is reported.
- Incremental mathematical novelty. The bias of SNIS/ratio estimators and its delta-method leading term are classical results. The ABC estimator is essentially the standard first-order SNIS correction.
- FID is the sole quality metric. Given small effect sizes and overlapping error bands, precision/recall or density/coverage would add meaningful signal and reduce the risk that reported improvements are FID noise.
- Table 2 (samples-to-FID) is fragile. First-hit-time on noisy FID curves with unmotivated thresholds ($\leq$10, $\leq$7) and attainment flags (Standard reaches FID$\leq$7 in only 1/3 seeds at ) does not support the convergence speed claims.
Questions
Major - I would be primarily looking at the responses to the following questions to revise my scores post rebuttal:
- Reconcile Figure 2 with Table 1. Figure 2 shows that at small (4, 8), the Standard and ABC bias curves nearly overlap, meaning ABC provides minimal bias reduction in precisely the regime where Table 1 claims the largest FID gains. Can the authors run a controlled ablation isolating the bias-reduction mechanism from the shrinkage/variance-damping effect of the factor? For instance, comparing against a version that applies the shrinkage weight without the corrective term would clarify whether FID gains are due to bias reduction or variance regularization. This reconciliation is the single highest-priority item for the rebuttal.
- Strengthen the statistical evidence. Can the authors report a paired significance test (e.g., paired -test or Wilcoxon) across seeds? In particular, what is the significance of the FID improvement (6.40 vs. 7.31), and can the authors confirm whether the best-FID regression (3.40 vs. 3.24) is within or outside noise? The current "mean max-deviation" does not support the claim that ABC improves at every tested .
Minor:
- Reframe novelty relative to classical SNIS correction. The ABC estimator is essentially the standard first-order bias correction for ratio/SNIS estimators (cf. Hesterberg, Owen). Can the authors add a remark in Section 4 explicitly stating that the bias formula is a specialization of classical results, and foregrounding the three genuinely novel elements: (i) identifying the drifting-model centroid as an SNIS estimator, (ii) the convex-hull containment guarantee (Prop 4.2), and (iii) the temperature-substitution impossibility (Appendix D)?
- Justify the practical regime. The introduction motivates drifting models with molecular sampling, medical image synthesis, and control applications. Why is small per-class a realistic constraint in these settings? Optionally, if time permits, can the authors characterize the distribution of practical in at least one of these domains, or provide an experiment at a larger regime (e.g., ) to clarify when ABC helps and when it does not?
Limitations
Yes
Paper formatting concerns
NA
Final justification
The authors' have provided a satisfactory response to all the questions I raised. The new ablation results conclusively proves the effectiveness of the proposed approach. I am happy to raise the score from borderline reject to borderline accept.
We are grateful for the exceptional depth of this review, and are very excited to know you verified our central results by independent re-derivation! We have carefully considered each of your detailed comments and have addressed them one by one to alleviate your concerns.
On the apparent gap between the toy experiment and the CIFAR claims, we would like to first clarify the scope of the toy experiment, which we will also make explicit in the revision. The toy experiment serves as a verification of our Thm. 3.3 and Thm. 4.1 in a controlled setting where the exact population centroid is computable. It involves different data, a different task, and no trained model, so its small n behavior should not be read as a direct quantitative prediction for real scenarios like CIFAR-10 generation. We would also note that the near overlap at n=4,8 does not contradict our theory. Thm. 3.3 is an asymptotic expansion, and at such small n the higher-order remainder is comparable to the leading term, as noted in Sec. 5.1.
To further confirm that the CIFAR gains come from bias correction, we ran exactly the ablation the reviewer requests. We implemented a shrinkage-only variant that applies the damping factor while dropping the corrective term, i.e. Tnshrink=(1−∑iαi2)Tn, with all other settings identical to the runs in Fig. 3, and report the mean FID trend during training over 3 seeds.
These results match the theoretical prediction. The corrective term that the shrinkage-only variant drops is itself of order O(1/n), so its residual bias remains O(1/n), the same order as Standard. Consistently, the shrinkage-only variant stays close to or even worse than Standard at both n, and is clearly behind ABC throughout. This supports that ABC's improvement comes from removing the bias rather than from shrinkage or variance damping, and we will add these results and relevant discussions in the revision.
Per the requirement of the reviewer, we first computed the requested paired t tests on the Tab. 1 runs. Cells give the two-sided p value.
No single cell reaches p<0.05, and we believe this reflects the randomness that a three-seed setting cannot avoid. We therefore pool all 12 (n,seed) pairs. The pooled Wilcoxon test gives p=0.027 on the last-5 average, so the improvement from ABC is statistically significant once the evidence across n is combined. On best FID the same pooled test gives p=0.15. Regarding the reviewer's specific question at n=64: the curves there show parity, as the O(1/n) theory predicts, with the last-5 average slightly favoring ABC (3.52 vs 3.77) and its p=0.59 confirming that this difference is not significant. The best-FID regression the reviewer highlights is within noise (p=0.10), and its direction has a mechanical explanation rather than a quality one: a minimum taken over a training curve favors the more volatile run, and at n=64 the Standard curves are indeed more volatile than ABC's (the within-run standard deviation of the final five evaluations averages 0.52 for Standard vs 0.10 for ABC), which is also why Standard's best FID there is reliably low while its average is worse.
Note that every seed here is a complete training run of up to 4,000 epochs, and Tab. 1 already rests on 24 such runs. Our three-seed setting matches or exceeds the typical reporting convention in the literature. For example, the original drifting models paper reports each configuration from a single training run without across-run error bars, and we are not aware of similar generative modeling work at comparable training cost that trains tens of seeds per configuration for significance testing.
We would also point to the full trajectories in Fig. 3, which support the superiority of ABC while being less subject to the randomness of any single checkpoint. The ABC curve runs below the Standard curve for essentially the entire training progress, with the clearest and most persistent gap at n=8. Also, the Precision/Recall results in W4 provide a quality signal independent of FID, further reducing the risk that the reported effects reflect metric noise. Therefore, we believe the statistical tests above, together with all the existing evidence, consistently indicate the superiority of our ABC.
We would like to first clarify that our paper has already stated the relationship to the classical results explicitly: the introduction notes that "bias in ratio estimators and self-normalized Monte Carlo estimators has long been understood" (Sec. 1), and the proof of Thm. 3.3 attributes the leading-order gap to "the classical delta method for self-normalized estimators" (Sec. 3). Following the reviewer's suggestion, we will add a remark to Sec. 4 that explicitly states the bias formula is a specialization of classical results.
We thank the reviewer for the concrete and insightful suggestion. We computed improved Precision/Recall (Kynkäänniemi et al., NeurIPS 2019) with the same protocol as Tab. 1. We report both k=3 (the setting of Kynkäänniemi et al.) and k=5 (the
prdclibrary default). Cells read Standard → ABC.It is clear that ABC improves Recall rather than Precision. This is consistent with what our theory predicts. Thm. 3.3 shows the bias is a contraction of the centroids of the drifting field (see the discussion in Lines 167-173), which suppresses diversity, and ABC removes precisely this contraction. The correction is therefore expected to recover Recall and leave Precision untouched, exactly as observed. Also, the Recall gain from ABC is large at n=8, shrinks through n=16 and n=32, and vanishes at n=64, which is consistent with the O(1/n) trend. These results provide an independent signal beyond FID that the reported improvements reflect the predicted mechanism of bias correction. We will add these results to the revised Appendix.
We would like to first note that time to reach a target FID is an established speed measure in the generative modeling literature. Projected GANs' headline claim is matching prior FIDs up to 40× faster (Sauer et al., NeurIPS 2021), and curves of FID versus training progress are the standard presentation in StyleGAN2-ADA (Karras et al., NeurIPS 2020). Therefore, we follow this practice, and the results consistently show the superiority of ABC in training speed. We will add these references in the final revision.
Nonetheless, we agree that first hit times on noisy FID curves with two thresholds are fragile to some extent, so we present additional evidence to further confirm the speed conclusion. First, we sweep the target over a range of thresholds instead of two values, under the same protocol and units as Tab. 2. At n=8, ABC reaches every threshold with fewer samples on average, and attains the tight thresholds in more seeds:
Second, the mean FID over the final 50% of the training budget, a statistic that involves no threshold and no minimum at all, also favors ABC at all four n.
To the best of our knowledge, the applications built on drifting models so far all operate at small per-condition n, with stated counts far below the n=64 of our largest setting, for example n=2 to 4 in one-step RL policies (arXiv 2605.07727), n=4 in learned channel simulation (arXiv 2606.17893), and n=16 in MRI-to-CT synthesis (arXiv 2603.28498). This is no coincidence, as a given condition usually comes with only a few samples in conditional generation, so a small n is intrinsic to the task rather than a design choice (see our response to Q1 by Reviewer pJPD for more discussion). Therefore, small n appears to be the common operating point of many applications, where the bias is large and our ABC is most effective.
On the optional larger n experiment, we trained a comparison between Standard and ABC at n=128, where the two variants converge to nearly the same level (Standard vs ABC: best FID 2.88 vs 2.68, last-5 average 3.08 vs 2.92). More details are in our response to Q2 by Reviewer pJPD.