- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper proposes a diffusion-based gaze generation model that jointly models continuous eye-tracking trajectories and discrete scanpaths. This joint representation lets the model simultaneously capture fine-grained saccade dynamics and high-level semantic attention structure, enabling variable-length generation via a validity-prediction head. The paper further contributes an energy-score-based CRPS evaluation framework that jointly rewards both generation accuracy and diversity as a proper scoring rule.
Strengths and weaknesses
Pros:
- This paper is well-written and well-organized.
- The contributions of joint scanpath-trajectory modeling and CRPS evaluation framework are well-motivated and clear to me.
- The experiments are extensive and make the results convincing with the ablations.
Cons:
- Since the proposed method generates raw continuous gaze trajectories via a diffusion process, it would be helpful to report the inference time and clarify the number of denoising steps used. It is also worth investigating whether the model can produce reasonable results with fewer steps.
- The joint modeling framework appears to require paired scanpath and trajectory annotations for training, which may place higher demands on the dataset compared to scanpath-only methods. A brief discussion on this data requirement and its implications for broader applicability would be valuable.
- No cross-dataset evaluation is presented in the paper. Adding experiments where the model is trained on one dataset and tested on another would help verify the generalization capability of the proposed approach.
Questions
See Cons above.
Limitations
yes
Paper formatting concerns
None
Final justification
My concerns have been resolved. I will keep my score as 4.
Inference Efficiency
Our current implementation follows the standard DDPM sampling procedure with 1000 denoising steps, following baseline DiffEye and ScanDiff settings. On a single RTX 4090 GPU, generating 10 trajectories in parallel for a single stimulus requires approximately 40 seconds. We additionally evaluated reduced-step inference by sampling with 500 denoising steps using the same model trained with the 1000-step DDPM schedule. As shown below, generation quality degrades substantially across both COCO-Search18 settings, indicating that the current DDPM formulation is sensitive to aggressive reductions in the number of denoising steps. Consequently, the present implementation relies on the full 1000-step sampling schedule to maintain generation quality. These results suggest that substantially faster inference will likely require algorithmic improvements beyond simply reducing the number of sampling steps. An interesting direction for future work is to investigate more efficient generative frameworks, such as flow matching, which have demonstrated high-quality generation with significantly fewer inference steps. We will update the implementation details, limitations, and future work sections accordingly.
COCO-Seach18-TP
COCO-Search18-TA
Paired Data Demands
Modern eye trackers record high-frequency gaze trajectories (e.g., 1000 Hz in COCO-Search18 and COCO-FreeView), and scanpaths are subsequently extracted from these trajectories using standard fixation detection algorithms. Thus, the trajectory and scanpath are not independently annotated but are two representations derived from the same underlying recording. The primary practical consideration is therefore data availability rather than annotation cost: if raw trajectories are available, the corresponding scanpaths can be obtained automatically. The main overhead is storage, as raw trajectories are larger than the compact scanpath representation. We will add a discussion of this data requirement and its implications in the revised paper.
Cross-dataset Evaluation
We conducted the requested cross-dataset evaluation by training on COCO-FreeView and testing on MIT1003, and vice versa. The results under the CRPS evaluation protocol are reported below. As expected, performance degrades under cross-dataset evaluation due to the substantial domain gap between the two datasets. COCO-FreeView and MIT1003 both contain relatively few subjects and differ considerably in acquisition settings (e.g., recording equipment and initial sampling rate), image content, and spatial resolution, leading to different gaze distributions. Nevertheless, the cross-dataset models still produce reasonable results, suggesting that the learned trajectory-scanpath representation captures transferable gaze patterns despite significant domain shifts. We will include this discussion in the revised paper.