- Rating
- 5
- Clarity
- 4
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
NeuralBES is a model sitting in between accurate but unscalable physics-based building energy model simulators and scalable but physically unreliable data-driven models. Physics-based building energy models do not scale because they would need to be calibrated for an unfeasibly large number of homes. While data-driven models are scalable, their results are not interpretable and are not guaranteed to be physically realistic. NeuralBES targets a middle space simulating building energy using only metadata commonly found in tax assessor records and scales to millions of buildings and new climates while retaining physical interpretability. NeuralBES uses a shared encoder (across all buildings) to estimate a target building’s resistance and capacitance values based on common inputs. The use of a shared encoder avoids the need for building-specific calibration and predicting resistance and capacitance values which feed into a physically-based simulation (as opposed to freely predicting temperature straight from building metadata which wouldn’t enforce physical processes on the model, such as the buildings capacity to absorb heat). To achieve this the model is trained using ResStock (large dataset of building types) and End-Use Load Profiles (meter readings of electricity use); this large scale training allows the model to generalise. At the same time the training signal for the model is based on physical models (DOE-2 and EnergyPlus) which teaches the AI model physical relationships between thermal states and heating / cooling equipment. NeuralBES is compared to a range of ML baselines and a grey box RC model demonstrating it is physically bounded (compared to baseline ML) and achieves better performance compared to a grey box RC model.
Strengths and weaknesses
This is not my area of expertise, so I am not best placed to judge originality and significance of this work within its field. However, I thought it was very well presented, accessible, and high-quality paper. I would recommend acceptance if that aligned with reviewers with subject matter expertise.
Overall, the paper was well written with a clear structure that made the work accessible and engaging; this helped communicate and explain the (relatively complex) approach the authors took to ensure their ML solution was physically based. The succinct introduction, followed by a clearly structured positioning of NeuralBES against existing work, before a detailed but well written methods provided a layered description and explanation of the approach developed here. Further, the BEM primer in the appendix was a good addition contributing to making this work accessible to general readers and is indicative of the quality of the overall presentation / communication of this work. The initial results comparing NeuralBES to baseline models was clear, but some of the additional interpretation of baseline models versus NeuralBES was hard to follow without a more detailed explanation of the baselines (as discussed below).
The authors clearly articulates NeuralBES’s original contribution versus existing and alternative building energy modelling approaches (grey box models are too costly to calibrate per-building at scale; NeuralBES differs from other physics-informed neural models by imposing a fixed RC-structure learning coefficients rather than dynamics and using a predictor-corrector loop to handle a thermostats on/off behaviour). This is achieved through large-scale training (via ResStock and End-Use Load Profile datasets) but using physical models (DOE-2 and EnergyPlus) to provide the training signal. This allows NeuralBES to scale simulations to a large number of while remaining physically bounded and using a conservation-law backbone, which sets it apart from other emulation approaches as set out in Section 2. Also, the innovations presented here allowing temperature simulations to be run in parallel as opposed to sequentially were interesting, well motivated, and dovetailed nicely with the stated aims of running across large building stocks.
A core strength of this paper is how this work is positioned against both unscalable physical models and scalable, but physically unrealistic, data-driven models. The paper does present a comparison of NeuralBES against a suite of different ML models and demonstrates it outperforms them while remaining physically bounded and states these baselines span the inductive bias spectrum with a limited description of the baseline architectures in tables 4 and 5 in the appendix. There is scope to more clearly explain the differences between these baseline approaches and why each of them are useful as comparisons to NeuralBES. I note the authors include a grey box RC baseline model, and this might be me overlooking something with my limited experience of these models, but I would welcome further explanation of this baseline model and how this is different from the unscalable physical models that NeuralBES is positioned against. A more complete explanation of the baseline models would have helped with interpreting Figure 3 and the related discussion in the final three sub-sections of section 4.2.
I was also curious as to the difference in performance of NeuralBES versus a “best-practice” physical model, even if this was for a small sample of test set buildings. I think that would be useful ancillary analysis to ascertain how close NeuralBES is to bridging the gap to physical models. How does an RMSE of 2.78 dec C for NeuralBES compare to physical models and what does this error mean for applied uses of the model?
Questions
How did the performance of NeuralBES vary with different types of buildings?
With an RMSE of 2.78 deg C, what downstream applications can this model be used for? And, what is the gap in accuracy of NeuralBES to purely physical based models?
Part of the motivation for NeuralBES was to scale to large numbers of buildings. How far away is NeuralBES from being used for these kinds of analyses? And what would be the impact of being able to undertake such analysis? Addressing these points in conclusion / limitations sections would be useful and round the paper off.
Limitations
Broadly, yes. However, as stated above I think there is scope for further explanation of the baseline comparison models and also contextualising the model’s performance relative applied uses.
Paper formatting concerns
N?A
Final justification
I thank the authors for their detailed rebuttal. Overall, I thought this was a well positioned and written paper and interesting analysis. I would strengthen my recommendation for publication if a more detailed explanation of the baseline and benchmark models was added to the manuscript. However, this is not my area of expertise so I will refer to other reviewers with domain expertise for comments on the novelty of this work.
Response to Reviewer Nfft
We thank the reviewer for the positive assessment and for highlighting where the empirical scope and baseline roles need clearer explanation.
Baselines and the revised comparison
We will explain the comparison spectrum more directly: DLinear is a linear forecasting baseline; LSTM is recurrent; PatchTST and Roformer are attention-based black boxes; PI-Roformer adds a soft heat-balance residual to a Roformer trunk; RC Grey-Box performs a structured RC rollout; and NeuralBES combines that rollout with learned auxiliary physics and predictor–corrector control. Classical identified grey-box RC models are calibrated separately for each building. To create a population-scale, input-matched baseline, we equip the RC Grey-Box with the same metadata-to-parameter encoder architecture as NeuralBES (with independently trained weights), so both infer building-specific 3R2C coefficients from coarse metadata rather than receiving per-building calibrated parameters. The remaining difference is the rollout formulation: RC uses fixed COPs and a fixed setpoint band, whereas NeuralBES adds learned internal gains, wind-dependent infiltration, COP derating, schedule-aware setpoints, and predictor–corrector control; we will also equalize the currently unequal training-window overlap.
We will also revise the headline interpretation consistently with our response to Reviewer q6HF: a capacity-matched LSTM beats NeuralBES on every raw-error metric, and simple signed-Q/clipping projections repair pointwise mode exclusivity and bounds. Thus we will not claim that NeuralBES outperforms all baselines or uniquely lies on an accuracy/validity frontier; the narrower empirical advantage is off-state and duty-cycle fidelity.
Accuracy, heterogeneity, and the physical-model gap
EnergyPlus is the detailed physical simulator that generated the ResStock targets, not an additional predictor evaluated from the same coarse inputs. Therefore, the reported 2.79 °C annual Tair RMSE is precisely NeuralBES's emulation error relative to EnergyPlus under known weather, schedules, and occupancy; it is not a gap to measured reality. NeuralBES should not be presented as a replacement for design-grade simulation, comfort certification, or safety-critical building control. Its intended scope is population-level scenario screening, annual/load-shape studies, tariff and demand-response analysis, and retrofit prioritization. We have not yet validated a downstream decision metric directly, and will state that clearly.
The current paper reports regional rather than building-type stratification. This does not establish uniform performance across vintages, building types, or HVAC classes; we will add that stratified analysis or explicitly identify its absence as a limitation. Our new leave-one-region-out test further shows that temperature dynamics transfer better than load magnitude: held-out-region Tair changes by at most +0.12 °C and improves in two regions, while load MAPE worsens by 3–10 percentage points.
Readiness and scale
We agree that “scales to millions” was stronger than the evidence. We did not run a million-building throughput benchmark. The demonstrated advantage is reduced per-building input and calibration burden, not measured deployment scale. Before stock-scale operational use, the method still needs explicit throughput benchmarks, broader geographic and building-type evaluation, validation against measured data, forecast rather than perfect exogenous inputs, and support for modulating or more complex controls. We will revise the conclusion to distinguish this intended impact from demonstrated readiness.
For precision, NeuralBES is trained on synthetic ResStock/EnergyPlus trajectories; End-Use Load Profiles provides aggregate calibration context for the corpus rather than direct meter-level supervision of NeuralBES.