- Rating
- 5
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper proposes TSC-Net, a lightweight detector for AI-generated videos. Instead of processing full video frames, it selects high-/low-frequency patches, converts informative rows/columns over time into temporal slice representations, adds raw/first-/second-order temporal differences, and classifies them with a small Transformer. It reports strong GenVideo and AI-Artist results with much lower FLOPs than video-based baselines, and introduces a new AI-Artist benchmark from recent generators.
Strengths and weaknesses
Strength:
- The combination of frequency-aware patch selection with temporal-slice inputs is interesting and well-motivated.
- It offers a faster, lightweight alternative to a full video analysis
- The paper is well written and explains the method well.
- The results show both strong performance compared to other methods and high efficiency.
- The new benchmark of AI-generated videos is a valuable contribution since the benchmark should keep evolving to keep up with the strength of the generative models.
Weaknesses:
- Several questions on the particulars of the method choices arise (see the questions section)
- All of the ablations are pushed into supplementary material; it would be useful to see at least some in the main paper.
Questions
Questions and comments:
- Only a single temporal segment was extracted from the video, centred on a key frame. It would be interesting to see ablations on multiple such segments.
- Since the central representation is built from row-wise and column-wise temporal slices, it would be useful to include in the main paper—and perhaps expand—the ablation comparing slice construction against direct temporal patch modelling, row-only/column-only variants, and selected-patch baselines.
Limitations
yes
Paper formatting concerns
n/a
Final justification
The authors addressed my comments and questions in the rebuttal, reinforcing my decision to recommend acceptance of the paper.
Thank you for recognizing the motivation, efficiency, empirical performance, clarity, and value of AI-Artist. We agree that temporal coverage and the central representation ablations deserve a more prominent presentation.
Q1. Ablation with multiple temporal segments
Thank you for this perceptive suggestion. We retain the scoring rules of the submitted method and change only how the fixed slice budget is distributed. The per-direction slice budget remains npick=8, comprising four HF and four LF slices in each of the row and column branches. The new variants change only how this fixed slice budget is distributed across patches or temporal segments. For 1-Seg. MP, we select the single key frame using the maximal mean temporal-difference score dt in Eq. (1), construct one temporal window, and rank its candidate patches using the gradient-energy score S(r,c) in Eq. (2). We then retain the four highest-energy HF patches and four lowest-energy LF patches and assemble their row/column slices. For 4-Seg, we rank frame transitions by the same dt score, apply temporal NMS to suppress neighboring peaks, and select the top four remaining key frames. A temporal window is constructed around each key frame, and the original patch-localization rule selects one HF/LF patch pair from each window. The resulting assembly again contains four HF and four LF slices in each directional branch. Thus, all configurations have the same model input shape; they differ only in how their evidence is sampled.
Under the matched eight-slice-per-branch budget, distributing evidence across multiple temporal segments is consistently better than concentrating additional patches within one segment. This indicates that broader temporal coverage provides complementary evidence not replicated by denser spatial sampling. Because the model input shape is fixed, model-forward latency remains essentially unchanged; the additional cost of 4-Seg lies in data processing because more frame windows must be accessed and their slices constructed separately. The submitted single-segment design remains the simpler operating point, while 4-Seg is favorable when accuracy is prioritized.
Q2. Slice construction versus direct temporal patch modeling, row/column variants, and selected-patch baselines
We agree that these central ablations should be presented more prominently.
Patch-based controls already in Table 5. Select Patch preserves informative-region selection but does not reorganize the content into temporal slices; it obtains 0.9871/0.9846 and 0.9644/0.9684 mAP/mAUROC on GenVideo and AI-Artist, respectively. Resize, which directly resizes the temporal video content, obtains 0.9919/0.9893 and 0.9541/0.9365. Both remain below the full model (0.9973/0.9967 and 0.9805/0.9773), isolating the benefit of slice construction from patch selection or direct resizing alone.
New directional variants. We additionally evaluate the row-only and column-only variants:
The new results show that row and column slices are both individually effective. Column-only is slightly stronger on AI-Artist, whereas their joint use is stronger on all GenVideo metrics, suggesting a dataset-dependent directional preference rather than a universally superior direction. The row-and-column design avoids selecting a direction using test-distribution knowledge and provides a robust cross-benchmark default.
We will add the new temporal-coverage, Only-Row, and Only-Column results to supplementary Table 5 and move a compact version of these central slice-construction ablations, together with the corresponding analysis, into the revised main paper.