- Rating
- 5
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 4
- Significance
- 3
Read review
Summary
The authors propose a method for improving the generation of molecular structures within the diffusion framework. In particular, the authors demonstrate that the existing approach of Gaussian noise for diffusing the atom coordinates is not suited well to the domain of molecules. Thus, SSD is developed as an alternative that takes various chemistry considerations into account. This is used in a variety of existing baseline models to demonstrate consistently improved performance.
Strengths and weaknesses
Strengths
- "Simple" idea (I expected something like this to be tried already), great execution of the idea as it clearly seems to work.
- Very thorough and convincing experiments. The proposed approach seems to work with a variety of good (published) baseline models in a plug-and-play manner, which is promising for applicability in future models.
- Ablations of all the major components of the proposed method are present.
- The narrative is clear. There is a reasonable motivation for the method and what problem it fixes. I like the presentation of particular case studies to tease out particular beneficial properties of SSD.
- The equivariances built into the method suit the problem domain well.
- Promise of code release and inclusion of anonymous code repository.
- Limitations section (N.4) is honest about the drawbacks of the method.
Weaknesses
- SSD is targeted on a class of methods that are not necessarily state-of-the-art (Cartesian coordinate-based) and it is not clear to what extent the method can be transferred to those methods.
- There are no error bars on the experiments. While the overall trend is in clear favour of SSD and I don't think adding this changes much in terms of the overall message, the experiments would be stronger if their individual error was quantified.
Overall, I think this is a strong paper. Therefore would happily recommend acceptance.
Questions
- Given the results, SSD seems like a consistent benefit for coordinate-based diffusion. Are you aware of any cases where you would not want to use SSD? In what instances do you expect SSD's assumptions to not work that well? This would help clarify the boundaries of the contribution and clarify its placement in the literature.
- With many diffusion methods relying on a Gaussian prior and thus the Gaussian Annulus theorem applying, it seems like the molecular domain is not special in that sense. Why does this choice seem so important here, and what other domains do you think would benefit from a non-Gaussian prior? This answer would make this paper interesting to a broader audience than only the molecular modeling community.
Limitations
none
Paper formatting concerns
none
Final justification
I have considered the points raised by other reviewers along with the rebuttals by the authors, and I'm satisfied that this is a strong paper that has a solid place at the conference. In my opinion, the paper easily clears the quality bar after the rebuttal, both in terms of theoretical as well as empirical results.
We thank the reviewer for the positive assessment, and particularly for two questions that ask us to draw the boundaries of the contribution rather than defend it. Revisions named below are commitments for the revised version.
Q1 — Are there cases where you would not want to use SSD? When do its assumptions break?
SSD helps most where the prior mismatch is largest: big, flexible molecules and long-drift trajectories (Sec. 4.5; Table 14 gives +32.5 COV-R for $\ge$50-atom GEOM-Drugs molecules). By the same logic it helps least in three regimes, which we can now name concretely.
Table R5: Multimodal-radius robustness (conditional, SSD-SubGDiff). Equal numbers of QM9 and Drugs molecules, hence a single-shell mean of 13.8 Å. The three prior rows share one merged-set threshold; the reference row is a native-protocol ceiling.
A single global shell does degrade (84.5), and a mixture-of-shells prior recovers most of the gap (91.5) while still defining a fixed unconditional pT — so the limitation is real but has a principled fix, which we currently flag only as future work.
The underlying assumption is therefore narrow and checkable before use: the data must have a well-defined chemical scale that differs from the dimension-driven σT3n, that scale must be unimodal, and generation must happen in coordinate space. All three are checkable before use rather than after: when they hold, SSD is a consistent benefit; when they do not, the boundary is known in advance. We will add this as a "when not to use SSD" paragraph in App. N.
Q2 — The Gaussian Annulus theorem applies to many diffusion models, so the molecular domain is not special in that sense. Why does the choice matter so much here, and what other domains would benefit?
This is the right framing and we will adopt it to broaden the paper. The annulus phenomenon is indeed universal; what makes it bite is the conjunction of two properties that are not universal:
Table R4: Synthetic atom-count study (mechanism probe, not real COV-R). The per-atom radial profile is held fixed (Δatom≈4.6 Å) and only n varies; non-physical at large n by construction.
With chemistry held constant, the Gaussian baseline falls from 91.0 to 63.5 COV-R as the joint mismatch grows with n, while SSD stays flat (92.0 → 90.6). These are synthetic numbers and are not comparable to real COV-R, but they match the real stratified evaluation qualitatively (Table 14).
Fixed-resolution images satisfy neither: their scale is a normalisation convention that can be aligned with σT once and for all, and their dimension does not vary between instances. That is why the same theorem has not surfaced as a problem there.
By this logic the domains that should benefit from a scale-calibrated prior are those with an intrinsic physical scale and a per-instance-varying element count: 3D point-cloud and shape generation, protein and peptide backbone generation, crystal and materials generation, and set-structured diffusion generally. We will add this discussion to the Introduction and Related Work so the contribution reads beyond the molecular community.
W1 — Transfer to non-Cartesian and to stronger methods.
We should correct how we have described this transfer path, because it is not "just swap in a coordinate encoder". Table 17 separates the two factors: replacing SemlaFlow's latent encoder with the EDM-style coordinate encoder by itself loses ground (Validity 99.4→97.6, MolStab 99.7→98.1), and it is the shell prior on top of that encoder which recovers and surpasses the original (+2.4 Validity, +4.9 Uniqueness, +1.8 MolStab over the matched Gaussian-Flow control). The accurate statement is that the coordinate encoder and the shell prior are jointly required — neither suffices alone. The controlled evidence for the shell itself is Table 17, where architecture, capacity, objective, feature set and step budget are all held fixed and only the prior varies; MCF adds the weaker but still relevant observation that the shell does not regress the strongest coordinate-space baseline we test (+1.1 on QM9, Table R3 — small precisely because MCF is near ceiling, Q1). Reaching latent-space SOTA in latent space would require reformulating the prior there, which we do not claim to have done. We will state this transfer path explicitly rather than leaving it implied.
W2 — Error bars.
Added. We reran the four principal pairs over three training seeds.
Table R3: mean$\pm$std over seeds 42/43/44 (std across runs, not of the mean).
The reviewer's expectation is borne out: the SubGDiff, EDM and Flow gains are large against their spread (EDM-QM9 +17.4 against σ≈0.6), so the overall message is unchanged. The one case where the error bars do change what we may claim is MCF-Drugs: +0.76 is about 1.8σ of the paired difference, so we report it as sign-consistent but not statistically significant rather than as a gain. Seed 42 — the run reported in Table 1 — lies inside every interval; the SSD entries that sit at the 100.0 ceiling there can only average lower. Tables 1–17 otherwise remain single-run, which we will state in every caption, and we will replace App. N.4(iii)'s assertion that the improvements exceed typical run-to-run variance with these measured spreads.