- Rating
- 5
- Clarity
- 2
- Confidence
- 5
- Originality
- 3
- Quality
- 3
- Significance
- 4
Read review
Summary
The paper introduces Frequency-Aware Flow Matching (FAFM), a method for producing continuous and temporally consistent action trajectories from demonstrations logged at heterogeneous frequencies. Rather than treating action chunks as step-indexed sequences, which becomes ill-posed when control frequencies vary, FAFM fixes the physical chunk duration and lets the number of action samples depend on the demonstration frequency. The method performs flow matching in the DCT frequency domain, so predicted coefficients define a continuous-time cosine-basis trajectory that can be evaluated at arbitrary temporal resolutions. It also applies flow matching to the first-order temporal derivative, using the continuous DCT representation to encourage smoother actions during inference.
Strengths and weaknesses
Strengths:
- Strong introduction and experimental setup. Involving a real-world robot is a big plus.
- The related work exhibition is thorough and paints a complete picture of the landscape.
- The authors consider a good number of baselines.
- The ablation study in 4.1.4 is very useful. The authors omitted to add a reference to the ablation results figure in the section 4.1.4 (Figure 6).
- The use of metrics that quantify motion smoothness from medical robotics is a big plus.
Weaknesses:
- Appendix G: the authors write “And we set DCT coefficients M = 16, because the chunk horizon is 50.” in the “VLA setting” paragraph, while this is the object of the next paragraph, “DCT coefficients”. The sentence starts with “And” and its contents are fully repeated in the next paragraph; I think this sentence can be deleted from that first one.
- Appendix G: The paragraph on “DCT coefficients” appears as the very last item in the paper, but I think this point deserves more attention earlier on. In particular, readers would likely be interested in understanding how much FAFM can compress the input signal while still outperforming the baselines. An ablation on the compression rate M/K would be a valuable addition, although I do not view it as strictly necessary given that the paper already covers substantial ground.
Minor:
- Reference 15: revise formatting (underscore in author name, etc.).
- Reference 18: revise as well.
- L89: “GR00T series”: space missing before reference.
- L110: the last sentence is missing a verb.
- L118: “in pi series” -> “from the pi series”?
- L185: “increases”.
- From Eq. 12 to Th. 1: P_M appears before its introduction in the theorem.
- Figure 5: “a” and “b” referred to in the caption are not on the figure. E.g. use “top row” and “bottom row” instead.
- L261: “lvel” does not follow the LaTeX formatting previously introduced in the paper.
Questions
- For Eq. 5 to be a “finite DCT-II sum” approximation to the continuous-time cosine projection integral written in Eq. 6, aren’t the authors missing a 1/K factor in Eq. 5?
- Section 4.2.1: In the mixed-frequency LIBERO experiment, does “chunk horizon 50” mean 50 action steps for every demonstration regardless of recording frequency, or does it mean a fixed physical duration corresponding to 50 steps at a reference frequency? If the former, the physical duration of a chunk differs across 5/10/20 Hz data, which seems inconsistent with the paper’s claim that FAFM fixes physical chunk duration T_xi and lets K=floor(T_xi * f_xi) vary with frequency. If the latter, the authors should explicitly state the reference frequency, the resulting physical duration, and the actual per-frequency sample counts used to compute DCT targets. This is a fundamental clarity issue that should be addressed, as it directly affects the validity of the mixed-frequency claim. From the code, (M+1=17) appears to be chosen as roughly one third of the canonical post-resampling horizon (K=50), not one third of the raw source horizon, which varies across 5/10/20 Hz inputs (respectivement “K source” of 25/50/100). So it is a ~3x compression for 10Hz, a ~1.5x compression for 5Hz, and a ~6x compression for 20Hz.
- [Related to previous point] The authors do mention at the very end of the conclusion that FAFM “is less effective for tasks that intrinsically require high-frequency or impulsive actions due to the nature of DCT”. Wouldn’t keeping more frequencies solve that issue, for the specific scenario where high-frequency jumps are part of the desired learned behavior? In the mixed-frequency setting, the largest frequency-domain representation that can be shared across all source frequencies without extrapolating beyond the lowest-rate data would be M+1=25, since the 5Hz source provides only a “K source” of 25 samples over the fixed 5s window.
- Have the authors noticed a difference in behavior quality, at inference time, between a fully open-loop execution and a receding-horizon execution?
- Could the authors clarify exactly what differs between standard FM and FAFM when both the DCT representation and L_vel are removed? In particular, it would be helpful to spell out the remaining conceptual and implementation-level differences, if any.
Limitations
Yes
Paper formatting concerns
No
Final justification
No more concern. I like the paper, and raise my score.
We thank Reviewer 4Y1g for recognizing the experimental design, real-robot validation, baseline coverage, ablation study, and motion-smoothness evaluation. We also appreciate the reviewer for identifying important clarity issues concerning DCT normalization, the physical-time construction of the mixed-frequency experiment, coefficient truncation and compression, and the execution protocol. We respond point by point below.
We thank Reviewer 4Y1g for raising this point. We will add this 1/K factor in final revision, luckily other results remain unchanged.
The unmodified baselines construct action sequences using a fixed
action_horizon=50, corresponding to the former construction; the source-data frequency is not used to adjust this step horizon. FAFM instead fixes the physical chunk duration to Tξ=5s, corresponding to the latter construction. For a demonstration recorded at frequency f, we use Kf=⌊fTξ⌋ raw samples over the same physical interval, i.e., Kf=25,50,100 for f=5,10,20Hz, respectively, and transform each variable-length sequence into the same fixed-dimensional DCT target with M=16, corresponding to M+1=17 coefficients. Thus, the reviewer’s interpretation of the source lengths is correct.The reviewer is also correct that the resulting compression factors differ across frequencies: they are approximately 1.47×, 2.94×, and 5.88× for 5/10/20 Hz data, respectively. However, FAFM aligns the retained physical frequency band rather than the discrete compression ratio. For fixed Tξ, the j-th DCT mode corresponds to the physical frequency νj=j/(2Tξ), so the same M yields the same cutoff frequency for all FPS values. With Tξ=5s and M=16, all three sources retain the same 0-1.6 Hz band. The different-frequency trajectories therefore estimate the same coefficient set at different sampling densities and can be mapped into a shared coefficient space. We will move these information from Appendix G to the main text, and clarify the source length, coefficient count, compression factor, and physical bandwidth.
We fully understand increasing M raises the maximum representable physical frequencies. In fact, our method should be effective if the task is of narrowband high-frequency, and keep the high-frequency part only. These tasks include polishing, wiping, stirring etc, which is stationary and periodic. However, if the task contains broadband high-frequency, such as impacts, percussive contact, then our task may not be the best fit since modelling higher frerquency also introduce stronger emphasis on higher order dynamics, which can dominate the loss itself.
Additionally, we added a three-seed ablation on Rope Threading to quantify the trade-off between different M:
The result implies that robot actions are inherently of low frequency, even maintaining M=1,2 produce lower yet reasonable success rates, while maintaining more frequency components with M=4 yields best success rates. In contrast, maintaining higher frequency M=6,8 additionally models the high-frequency demonstration noise, discretization error and high-frequency prediction residuals to enter the output, resulting in low smoothness. Thus, we select M=4 which corresponds to M/K=1/3 which reflects a trade-off between task performance and smoothness. We will revise the limitation accordingly and move the M-selection discussion earlier in the paper.
All reported results use a unified receding-horizon protocol, which is consistent with the standard protocols of π0, Diffusion Policy, and the other action-chunk baselines. We didn't tested open-loop execution since it inevitable introduce execution errors. The VLA experiments follow the OpenPI action-chunk execution protocol; in obstacle avoidance and LapGym, all methods predict 12 actions, execute the first 5, and replan every 0.5 s at 10 Hz.
No difference remains when both components are removed. Without the DCT representation, flow matching is performed directly on the original time-domain action chunk; after also removing Lvel, the objective becomes LFM directly.
Thus, FM baseline is included in our Ablation in Fig. 6 as a reference without DCT and L_vel, with the same backbone, conditioning pathway, flow interpolation, ODE solver, optimizer, and chunk horizon, and with no additional parameters or hidden implementation differences. No additional experiment is required because this configuration is precisely the existing FM baseline.
Thanks for carefully proofreading our paper and the helpful suggestions. We will correct them in revision.