- Rating
- 5
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The authors introduce pCoMole, an offline method for multi-objective and constraint-aware editing of biomolecular sequences. Illustrated through sequence shrinkage tasks, the work is motivated by the incapacity of existing controllable discrete generators to handle multi-objective optimization, hard terminal feasibility and variable-length editing.
Its method consists in leveraging a pre-trained Edit Flow (in essence, an adapted discrete flow matching with insert/delete/substitute operations) steered towards a desired feasibility-gated terminal distribution. At its core, pCoMole approximate intractable harmonic function with short Monte Carlo rollouts over sampled candidate edits, then apply Doob-h transform to "tilt" the velocity of the edit flow.
Experiments include three in-silico shrinkage tasks: GFP, Cas9 (PAM preservation) and peptidomimetic binder compression over seven ADMET-style properties.
Strengths and weaknesses
Strengths:
- Narrative flow: The manuscript is easy to read and well-written overall from motivation to experimental settings and results.
- Method formulation: The authors ground their discrete flow approach with strong mathematical propositions and a principled way to utilize Doob-h transform to "tilt" the sampling while preserving the base edit kernel.
- Details and reproducibility: Implementation details and code are provided (though the codebase remains in an experimental form with local paths/artifacts/commented-out code, and is currently not ready for public release).
Weaknesses:
- Predictors: My main concern is that the authors use the same predictors (FPredX, Protein2PAM, Boltz-2) that are learned oracles, for both the objectives and evaluation oracles. I suspect the possibility of the empirical gains being due to off-distribution extrapolation rather than biology or soundness of the method. Also for Table 6, as pCoMole is compared to known binders and no generative baselines, improvements mainly rest on the predictor calibration at edited scaffolds (e.g. GLP-1R half-life from 1.86 to 4.03h).
- Evaluation fairness: for the claimed 100% PAM match (Section 4.3), making the feasibility constraint hard-by-construction in pCoMole may be unfair for baseline methods. For the GFP experiments, Raygun and SCISOR never optimize for brightness/excitation and are shrinkage-only.
- Statistical significance: Most results are averaged over generated candidates, without variance or confidence intervals and appear single-run.
Comments & Remarks:
- The manuscript reference [25] metadata should be updated to recent ICLR'25 publication.
- The manuscript being very dense, it defers entire important sections to the Appendix (such as "Related Work" and "Model Architecture") rather than keeping them in the main content.
- For a broader ML audience less familiar with the field, I'd recommend adding a short passage explaining why the doob-h transform is chosen over another method.
- Note to the AC: I have reviewed mathematical propositions in the main content but did not verify in detail all proofs in Appendix.
Questions
Following some points raised in "Weaknesses":
- Statistical significance would strengthen the results reported in tables.
- For Monte Carlo rollouts scaling laws, could you ground or discuss beyond the quantitative ablate analysis in Appendix D/Tables S6-8, notably for the number of objectives? (non-exhaustive suggestions to the authors - on multi-objective MCTS [1] [2] [3]).
- For scalar properties (brightness, half-life, ADMET), is it possible to validate gains with an independent oracle for any task, maybe ADMET predictors? I do not expect thorough ablations but at least pilot results to double-check the soundness of the method.
[1] Wang W., and Michele S. "Multi-objective monte-carlo tree search." Asian conference on machine learning. PMLR, 2012. [2] Southiratn et al. "CombiMOTS: Combinatorial Multi-Objective Tree Search for Dual-Target Molecule Generation." International Conference on Machine Learning. PMLR, 2025. [3] Chen W., and Lantao L. "Pareto monte carlo tree search for multi-objective informative planning." arXiv preprint arXiv:2111.01825 (2021).
Limitations
The authors transparently acknowledge the lack of experimental validation, the computational costs from rollout guidance and possible failures under tight budgets.
Paper formatting concerns
None to be reported. Reference [25] of the manuscript should be updated.
Final justification
See Response to Authors' Rebuttal #1:
The authors addressed most of the concerns I raised in my first review, and asked additional questions on sampling efficiency and variance in shrinkage outcome. I consider the authors' first rebuttal strong, and may increase my score depending on how they reply to my second review. The other main reason of me not immediately raising the overall score is because the manuscript, though of quality, is and becomes more and more dense and difficult to read. Notably, information is sparse (not well organized in the main content) and the reader is left to dig into the appendix to link all evidence.
I updated my Quality/Clarity/Significance/Originality ratings to match the "Use-Inspired" reviewing guidelines.
Update - After "Response to Authors' Rebuttal #2":
I acknowledge the authors' second response and now deem the work mature enough for me to raise my score from 3 to 5. The authors consistently provided pertinent elements and brought clarity on both the initial content from the manuscript and new content from the rebuttal discussion.
Though the current manuscript needs to reflect on the feedback from the review process, I believe that the authors can adequately integrate it in future versions.
We thank the reviewer for recognizing the paper’s clear presentation, principled Doob-h formulation, and reproducibility. We address the concerns about predictor robustness, evaluation fairness, statistical significance, and rollout scaling below.
W1a. Independent validation of learned oracles
Thank you for raising this important concern. We agree that evaluation with the guidance oracle alone does not rule out oracle exploitation or establish biological transfer. We therefore add held-out computational evaluation and direct experimental validation.
For Cas9, we evaluate Protein2PAM-guided designs with CICERO, an independently trained PAM predictor that was not used for guidance, filtering, selection, or tuning. As shown in Table R0 under Reviewer ffWP W1/Q3, CICERO exact PAM preservation increases from 4% to 88% for St3Cas9 and from 20% to 72% for GeoCas9 when Protein2PAM guidance is enabled, with corresponding improvements in PWM similarity.
For peptidomimetics, we clarify that Boltz-2 is not used for guidance. The in-loop affinity objective uses PeptiVerse, while Boltz-2 and AutoDock Vina are used only for post hoc evaluation. Boltz-2 supports favorable binding for selected designs, and Vina-docked poses occupy the intended parental pockets and engage overlapping interface residues, providing out-of-loop evidence for pocket-level recognition.
For GFP, we provide wet-lab validation independent of FPredX and all computational evaluators. As shown in Table R1 under Reviewer ffWP W1/Q3, two pCoMole-designed GFPs retained green fluorescence in BL21 cells after being shortened from 239 to 229 amino acids through 10 deletions. Full experimental methods, construct sequences, alignments, phase-contrast images, and 488-nm fluorescence images are provided in the anonymous repository in
pCoMole_shrunk_eGFP_experimental_results.pdf.W1b. Scope of Table 6
Thank you for this important clarification. We agree that Table 6 should not be interpreted as a comparison against an objective-matched generative baseline. The known therapeutic binders are incumbent reference molecules: the experiment asks whether pCoMole can edit an established binder into a shorter, constraint-satisfying peptidomimetic while retaining a favorable predicted property profile.
To our knowledge, no publicly available baseline supports the same setting of variable-length peptidomimetic editing from a fixed incumbent, simultaneous optimization of seven properties, and hard validity and length constraints. Table 6 is therefore intended as a clinically motivated editing case study rather than evidence of superiority over other generators.
We also agree that changes such as the GLP-1R half-life increase are predictor-dependent and should be interpreted as predicted improvements under the chemotype-adaptive ensemble, not experimentally established pharmacokinetic gains. For affinity, we provide additional out-of-loop evidence from Boltz-2 and AutoDock Vina, neither of which is used during guidance. Comparable independent validators are not currently available for all peptidomimetic ADMET properties, which remains a limitation.
We will revise Table 6 and the surrounding text to make this scope explicit and avoid implying experimental or baseline-relative superiority.
W2. Fairness of shrinkage baselines
Thank you for pointing this out. We agree that RayGun and SCISOR are not objective-matched baselines: they perform sequence shrinkage but do not jointly optimize multiple properties or enforce hard terminal constraints. To our knowledge, no existing method addresses the complete pCoMole setting of variable-length editing, multi-objective optimization, and hard terminal feasibility.
Accordingly, these comparisons answer a narrower but important question: is shrinkage alone sufficient to preserve the downstream biological specification? RayGun and SCISOR are included as the closest established shrinkage methods, not as methods solving the identical optimization problem.
For Cas9, the 100% Protein2PAM match should be interpreted as verification that pCoMole satisfies the imposed hard constraint, rather than as a standalone performance advantage over unconstrained baselines. For GFP, RayGun and SCISOR do not optimize brightness or excitation alignment. Their comparison with pCoMole therefore tests whether shrinkage-only editing preserves these task-critical properties, rather than constituting a like-for-like multi-objective benchmark.
W3/Q1. Uncertainty estimates
Thank you for requesting this important information. As detailed in our response to Reviewer cHFo Q3, we now report 95% confidence intervals for the principal GFP, Cas9, and peptidomimetic results. Continuous metrics use nonparametric bootstrap intervals, while proportions use Wilson intervals where reported.
Each candidate is generated by an independent stochastic editing trajectory under a fixed checkpoint, input sequence, evaluator set, and guidance configuration. The sampling units are 100 GFP trajectories per condition, 50 Cas9 trajectories per ortholog, and 100 peptidomimetic trajectories per target. For the 15-target peptidomimetic summary, we first aggregate within each target and then compute uncertainty across the 15 target-level means, avoiding treatment of all 1,500 candidates as interchangeable replicates.
The resulting intervals, shown in Tables R3a–R3c under Reviewer cHFo Q3, preserve the main conclusions: pCoMole’s GFP improvements over shrinkage baselines remain clear, Cas9 designs consistently shrink while retaining high predicted function and PAM agreement, and peptidomimetic results are stable across targets. We will add these intervals and sampling-unit definitions to the revised manuscript.
Q2. Rollout scaling with objectives
Thank you for this question and for pointing us to the multi-objective MCTS literature. Increasing the number of objectives K has different computational and statistical effects.
Computationally, for fixed edit-step, candidate, and rollout budgets, increasing K does not increase the number of simulated trajectories or expand the rollout branching structure. It only adds the cost of evaluating additional objectives and an O(K) augmented-Tchebycheff scalarization. Thus, cost grows through objective evaluation rather than combinatorially with K.
Statistically, pCoMole estimates one preference-specific scalar continuation value after scalarization: ht(x)=R1∑r=1RGK(X1(r)),SE[ht(x)]=RVar[GK(X1)∣Xt=x].
The Monte Carlo rate remains R−1/2, but the variance can depend strongly on objective conflict. As K increases, high-utility feasible continuations may become rarer or candidate value gaps may shrink, requiring more rollouts for reliable ranking. Equivalently, if a useful continuation occurs with probability pK, then R rollouts observe one with probability 1−(1−pK)R; smaller pK requires a larger rollout budget.
This differs from multi-objective MCTS methods that maintain vector-valued rewards, Pareto sets, or hypervolume statistics inside an explicit search tree. pCoMole scalarizes for a chosen preference vector before rollout estimation, so it estimates a single scalar continuation value. Broader Pareto coverage is obtained by running multiple preference vectors rather than by maintaining node-level Pareto archives. We will add this scaling discussion and clarify the distinction from multi-objective MCTS in the Related Work section.
Q3. Independent scalar-property validation
Thank you for this important suggestion. As discussed in W1a, we provide independent validation where suitable external evaluators exist: Boltz-2/Vina for peptidomimetic affinity and wet-lab fluorescence validation for GFP, both outside the corresponding guidance loops.
For GFP brightness and excitation, we are not aware of a comparable public predictor that can serve as a reliable held-out oracle; the wet-lab fluorescence assay therefore provides a stronger independent check than agreement between two computational predictors. For peptidomimetic half-life and ADMET properties, public models are generally calibrated for conventional small molecules or peptides, rather than hybrid peptidomimetic scaffolds. Moreover, Admetica is already part of our chemotype-adaptive guidance ensemble, so it cannot serve as an independent evaluator. We will clarify this limitation and avoid implying independently validated ADMET gains.
We hope the held-out CICERO evaluation, independent Boltz-2/Vina checks, wet-lab GFP validation, calibrated interpretation of Table 6, clarification of the shrinkage baselines and hard constraints, new confidence intervals, and objective-count scaling discussion address the reviewer’s concerns about biological validity, evaluation fairness, statistical reliability, and scalability. We would be very grateful if the reviewer would reconsider both their score and confidence in the submission.