- Rating
- 5
- Clarity
- 3
- Confidence
- 3
- Originality
- 4
- Quality
- 3
- Significance
- 3
Read review
Summary
- Standard NPE can produces approximate posterior whose mass concentrate on the training target , when density estimator is flexible enough.
- Standard regulariser could prevent this to some extent. But the posterior variance is still underestimated because data used to estimate posterior mean is also reused to estimate posterior variance.
- They suggest a method to estimate posterior mean and variance / residuals separately using different data to avoid this problem.
Basic workflow is as follow:
- Split data into K-fold
- Predict posterior mean using cross validation so that for in fold , mean estimate is estimated from the fold .
- Compute residual .
- Train conditional estimator on the residuals by maximising: with respect to
After the training, where is a observed data of interest.
Strengths and weaknesses
Strengths
- The paper is well motivated.
- It starts from the problem of mass concentrating behaviour of NPE. The authors show that standard regularisers could prevent this, but there still remains in-sample residual bias due to using same sample to estimate posterior mean and variance. This leads to underestimation of posterior variance. To prevent this, they suggest the separate estimation of mean and variance, which makes a lot of sense.
- They also empirically show this in Figure 2, where they demonstrate that standard NPE cannot have good estimation of mean and variance at the same time.
- The methods gives underconfident posterior which is usually preferred over overconfident posterior.
- The proposition 1 suggest that estimated residual variance upper-bound the true posterior variance. And under the perfect fit, it gives the exact posterior variance (Corollary 2).
- They conduct extensive amount of experiments.
- It has rich amount of ablation studies in appendix including comparison with various methods (appendix D4-6)
- It also include evaluation of the method in various setting including different amount of simulation budget (appendix D3) and different number of the folds (D7).
- It also has an interesting real world application on reconstruction of lensed galaxies.
Weaknesses
- Evaluation metric could be improved.
- I think the emphasis of the paper was the unbiased estimation of the posterior variance, but the selected metrics (log-likelihood, MSE) does not evaluate biases directly.
- Assumptions on the preposition 3 is not clear.
- “ contains a sequence…” (line 420-421). Not very clear when this assumption applies.
- Quality of Figure 2 could be improved.
- It is not clear why you are showing MSE for the mean but the ratio for the variance.
- Size of the font can be increased.
- It is not clear what “MSE-only minimum” is.
Questions
- Could you provide other metric for some of the experiments which could capture the quality of posterior variance estimation?
- It could be something like figure 2 for your method, simulation-based calibration [1], coverage curve used in [2], or C2ST used in [3] (when ground truth posterior samples are available).
- Could you clarify the assumption for preposition 3? Does it hold for gaussian or NSF used in the paper?
[1] Talts, S., Betancourt, M., Simpson, D., Vehtari, A., & Gelman, A. (2018). Validating Bayesian inference algorithms with simulation-based calibration. arXiv preprint arXiv:1804.06788.
[2] Hermans, J., Delaunoy, A., Rozet, F., Wehenkel, A., Begy, V., & Louppe, G. (2021). A trust crisis in simulation-based inference? your posterior approximations can be unfaithful. arXiv preprint arXiv:2110.06581.
[3] Lueckmann, J. M., Boelts, J., Greenberg, D., Goncalves, P., & Macke, J. (2021, March). Benchmarking simulation-based inference. In International conference on artificial intelligence and statistics (pp. 343-351). PMLR.
Limitations
yes
Paper formatting concerns
None
Final justification
Paper is well motivated and clearly written with extensive amount of experiments. During rebuttal, the author addressed my main concern about the use of test likelihood as a main evaluation metric and also provided additional metrics, which demonstrate consistently better performance of the proposed method over the baseline methods. I therefore increase my initial score and recommend acceptance.
Thank you for the high-quality review and the encouraging feedback. Let me try to address your remaining concerns.
Calibration metrics
Log-likelihood is a uniquely important metric in this work comparing approaches to NPE because NPE optimizes log-likelihood. We expect NPE to produce posterior approximations that are at least somewhat calibrated because maximizing held-out log-likelihood minimizes the expected KL divergence from the posterior to the approximation. That said, in an attempt to keep the manuscript’s narrative simple, I seem to have overdone it by only reporting test log-likelihood (all three reviewers and the AE comment on it). Thus, I’m pleased to report here that the proposed method performs very well across all the suggested calibration metrics:
In some settings, only CF-NPE produces calibrated posterior approximations. The magnitude of some of the differences in χred2 is striking.
Notes and caveats:
NSF optimization trajectory
It's not so bad! The Gaussian head in stage 2 is indeed more principled in that, by construction, its mean can be set to zero. The NSF head, however, at initialization, produces approximately mean-zero posteriors because neural networks are initialized with symmetric weights and biases. Thus, in CF-NPE, the conditional means are already nearly optimal at the beginning of the optimization trajectory. Then, during optimization, they don’t change much because their optimal value is also around zero. Because these conditional means stay roughly constant throughout optimization, the early stopping mechanism engages whenever the variance and other higher-order moments are best, without having to trade off their goodness against the goodness of the current iterate’s conditional means. I will make this (somewhat subtle) point clearer in the manuscript.
Simulation budget
The simulations are performed before the timer begins and saved to disk for consistency across runs; the reported times are for the inference alone. The simulator used, lenstromy, generates images of lensing systems fairly quickly, which makes development easier with finite computing resources, but limits the application’s relevance to the “simulation cost >> training cost" regime. That said, lenstronomy may be thought of as a surrogate for more computationally expensive high-fidelity simulations of strong lensing systems, which can take on the order of one day each [1], performing ray tracing and PDE solving and so forth, so there is a connection to the “simulation cost >> training cost" regime. I will be clearer about the extent of this connection in the manuscript.
[1] Gilman, D., Birrer, S., Nierenberg, A., & Oh, M. S. H. (2024). Turbocharging constraints on dark matter substructure through a synthesis of strong lensing flux ratios and extended lensed arcs. Monthly Notices of the Royal Astronomical Society, 533(2), 1687–1713.
I will follow up with multiseed strong lensing results in a subsequent post.