Read review
Summary
This article proposes a differentiable inverse modeling method for extracellular electrophysiology: starting from a multichannel MEA/Neuropixel recording and action potential-sorted units, it jointly adjusts a time-varying input current for each neuron and a 3D probe position , by backpropagation through a biophysical membrane model coupled to a differentiable volume conductor. The main technical contribution lies in addressing the poor conditioning of the trace adjustment loss (flat below the threshold, discontinuous at the action potential threshold) and correcting it with two additional anchoring losses. The evaluation is based on synthetic LIVN recordings and the SPE-1 patch-clamp/paired neuropixel dataset, including a comparison with the localization baselines of Zhao et al. and a modality consistency check against a whole-cell patch-clamp trace.
Strengths and weaknesses
I find the overall idea interesting and definitely worth pursuing. Figure 1 is very clear and convincing. The synthetic single- and two-unit ablations are also encouraging, with sub-30µm localization and 100% accuracy within 50µm, showing the anchoring mechanism works cleanly in the easy regime. That being said, I find the experimental results quite underwhelming: the gains over center-of-mass are modest at a much higher computational cost, the subthreshold voltage reconstruction would be unusable, and the performance drop in the four-unit case poses questions about the scalability of the approach. The authors are very frank about the limitations of their work, which they frame as a proof-of-concept, and I really appreciate this honesty. I however do not think that the originality and significance of the proposed approach are high enough to justify publication as a concept paper. The novelty claims as compared to Tanoh et al. mostly rely on the loss design with spike-anchoring, which is a good idea, but not groundbreaking. In this shape, I fear that the impact of the paper would sit well below its potential. I strongly suggest the authors to improve the implementation and experimental validation, and submit a revise version as a classical paper. I understand that my assessment can be discouraging, and I am of course open to discussion.
Questions
Could you please clarify why you believe the paper should be published at a "concept and feasibility" paper, even with very modest experimental results?
Limitations
Yes, the paper is extremely forthright about its limitations, which is very much appreciated.
Paper formatting concerns
None.
Final justification
The authors have properly answered my comments during the author-reviewer discussion, but I still have minor reservations. I have updated my score to a 4.
Thanks for the review and the honest feedback!
For discussion of the performance drop in the four-unit case, please refer to our response to the review by Reviewer QgVJ.
We agree that the added computational cost would not be justified by the localization gains if localization were the end goal. In our setting, however, the localization benchmark serves primarily as an evaluation proxy for the quality of the inverse fit, which is what matters for our actual objective of deriving a simulation that explains the recorded signal in terms of differentiable physics.
Simulation fitting in neuroscience has largely proceeded either by black-box optimization against hand-designed features or by simulation-based inference targeting a principled posterior, both of which reduce the recorded signal to low-dimensional summaries. We are aiming for a third route by fitting the simulator directly to the recorded signal as a point estimate, with a loss and forward model designed to keep the problem well conditioned. This trades uncertainty quantification for directness, and we present it as a research direction rather than a finished method. The appeal is that a differentiable parameters-to-signal path is amortizable, opening a route to inverse inference at a scale per-recording optimization cannot reach.
Finally, we would emphasize where we think the significance of this work lies. Simulation-based inference is predominantly validated on synthetic benchmarks, in which the generating simulator and the inverted simulator coincide, as in Tanoh et al. That is the right regime for assessing calibration, but it leaves open whether a mechanistic inverse fit is feasible on real recordings, where the simulator is misspecified and no ground truth is available to tune against. By fitting directly to the SPE-1 recordings, we show that an end-to-end differentiable inverse fit of a mechanistic simulator is possible on real data even if the sub-threshold voltage reconstruction it currently attains is modest. It is that feasibility, and the forward-model and loss design that make it attainable, that we believe justifies the direction.