- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 4
Read review
Summary
The main idea is to treat q as a frozen feature and the preservation result follows from this The evaluation done carefully and q is cross-fitted to avoid label leakage. The baselines include four different comparisons, namely the raw foundation model, a monotonic neural network, a feature-augmented MNL and a convex ensemble. Calibration is checked with three different post-hoc methods. There is a counterfactual aggregate-share test, and significance is reported with an exact sign test and per-seed McNemar rather than a single pooled number. Proposition 2 is a useful negative result, and it is particularly interesting because it is not obvious. It is accompanied by an empirical case, namely the cost-coefficient collapse in ablation A3. The authors note that it holds only when cost is recoverable from q.
Strengths and weaknesses
Strengths:
- The core idea is clean, deployable, and model-agnostic and the precomputed-q construction is simple. In my view the preservation result is exactly the property practitioners need which is nice.
- The evaluation is done thorough and I appreciated that significance uses an exact sign test and per-seed McNemar rather than a single pooled number.
- Proposition 2 is a nice non-obvious negative result (as mentioned in the summary), with a matching empirical illustration (the cost-coefficient collapse in A3), and it is appropriately discussed as dataset-dependent.
- The paper is very transparent about its limitations (bias-driven Swissmetro calibration, discrete-attribute audit precision issue, stage 1 misspecification inheritance++)
Weaknesses
- In my view the headline guarantee holds mostly by construction and depends on the fixed-q protocol. With ∂q/∂x = 0, g drops out of every derivative, and thus the trade-off ratio is the one of the MNL. The foundation model improves the fit on the observed choices but, as far as I can tell, adds nothing to the counterfactual response, which is the second stated goal of the paper, namely forecasting how choice responds to intervention. I think this is shown in Table 2. The adapter recovers only 40–97% of the share changes of the MNL and matches the sign of the MNL by construction. The "best of both worlds" framing overstates the result. It is worth noting that under fixed-q the foundation model buys accuracy on the observed choices and not better counterfactuals. In some tests I could confirm that for any random g, the utility- and probability-derivative trade-off ratios equal β_time/β_cost to machine precision.
- A realistic deployment requeries the foundation model on new inputs, i.e., recomputed-q, and I believe this breaks the guarantee. The chain-rule term through q returns and the trade-off ratio is no longer reduced to the coefficient ratio.
- The accuracy gains are quite modest overall. The adapter often performs worse than the raw foundation model and lands within about two points of the MNL on some cells, e.g., IoT-Wearables with 62.5 against 65.7 or 66.5. The feature-augmented MNL achieves a higher accuracy but with worse tradeoff ratios. Therefore I think the case for this method is mainly based on the guarantee and not on the accuracy which should maybe be made more clear in the paper.
- It looks like the Swissmetro calibration becomes worse rather than better. The post-calibration ECE is 8.4% and 17.0% against the 4.0% of the MNL and it is resistant to temperature scaling, isotonic regression and bootstrap ensembling because it is bias-driven. The paper does not report when this happens or how a practitioner would detect it before deployment, and I think it should.
- The contribution is a combination of different existing components together with theory and not a new model which is fine but it is rather incremental compared to the feature-augmented MNL baseline.
Questions
- Under fixed-q, does the foundation model add anything to the counterfactual forecasting beyond the MNL, or only to the fit on the observed choices?
- How should a practitioner handle the recomputed-q case, in which the guarantee no longer holds?
- What predicts the Swissmetro calibration failure, and can it be detected in advance?
- What does the embedding of q provide over running the foundation model for prediction and the MNL for counterfactuals as two different models?
Limitations
I think overall the limitations section is very good but it should be revised based on the weaknesses I flagged.
Paper formatting concerns
no concerns
Final justification
I think the authors did a good rebuttal. I am a bit concerned that this would be a lot to change for the final version. Thus I stay with my initial score of 4.
We thank the reviewer for independently verifying the preservation result to machine precision, and for weaknesses stated precisely enough to run experiments against. We ran them. All numbers below are new, computed on the submission's trained checkpoints, and the reconciled results will be added to the camera-ready.
New evidence for this response: (1) the recomputed-q protocol evaluated end to end (10 training-bootstrap replicates, both FMs, all cost scenarios); (2) a partial-q sweep qλ=(1−λ)qfixed+λqrecomputed at ±10/20/50% perturbations; (3) bootstrap CIs on the accuracy gains, subject-clustered on the panel dataset; (4) a measured validation-vs-deployment q-shift diagnostic for the calibration question; (5) TasteNet and knowledge-distillation baselines (numbers in our response to wfQU).
"The 'best of both worlds' framing overstates the result. It is worth noting that under fixed-q the foundation model buys accuracy on the observed choices and not better counterfactuals." / "Under fixed-q, does the foundation model add anything to the counterfactual forecasting beyond the MNL, or only to the fit on the observed choices?"
We agree with this boundary and will state it plainly. Under fixed-q the foundation model improves observed-choice prediction; the structural MNL supplies the certified derivatives. To be exact about what is preserved: the utility-derivative ratio (MRS), its probability-derivative counterpart, and the response sign are inherited from Stage 1. Aggregate share-change magnitudes are not: your reading of Table 2 is correct; the adapter recovers 40–97% of the MNL's magnitude because the correction shifts baseline probabilities and softmax curvature. The right description is accuracy plus preservation, not improved counterfactual response, and without held-out interventions or a credible elasticity benchmark we do not claim that either protocol improves counterfactual accuracy. For the camera-ready, the contribution bullet will name observed-choice accuracy explicitly, and the abstract will gain "; counterfactual derivatives and response signs are inherited from the multinomial logit by design."
"A realistic deployment ... the foundation model on new inputs, i.e., recomputed-q, and I believe this breaks the guarantee." / "How should a practitioner handle the recomputed-q case, in which the guarantee no longer holds?"
Deploying the FM on new inputs means two different things, and we should have drawn this distinction in the paper. (a) Computing q for a new individual is required and harmless: the contract is per-query. Compute q(xnew) once at the observed point, and Proposition 1 applies at xnew exactly as at any training row. The guarantee never required q frozen at training-time values. (b) Letting q respond within a counterfactual perturbation is what breaks the guarantee, as you state, and we measured it: the trade-off ratio drifts from the β∗ ratio by a median of 16–197% per cell (q90 up to ~770%), with a population-mean sign flip on one cell; and where the raw FM's counterfactual direction violates economic sign (LPMC transit cost), recomputed-q imports the violation, wrong direction in 10 of 10 replicates, while fixed-q is correct-signed in 16 of 16 cells. The guidance we will add for practitioners: compute q once per observed input; answer structural queries under fixed-q, where the guarantee applies; if a query needs the FM to respond inside the intervention, treat that as a different quantity, with the price we measured above; the safe range of λ differs across datasets, and we cannot identify it in advance.
"...the case for this method is mainly based on the guarantee and not on the accuracy which should maybe be made more clear in the paper."
Agreed; the camera-ready abstract and introduction will say the gains are modest where the MNL is already strong and that the contribution is the guarantee. Per-dataset gains with bootstrap 95% CIs (2000 resamples): Swissmetro +12.8/+13.1 pp (test-resampling CIs [+10.3, +15.1] and [+10.7, +15.5]); LPMC +3.1/+3.0 pp ([+2.6, +3.6] and [+2.5, +3.5]); IoT +4.0/+3.9 pp, subject-clustered because the data are panel ([+1.8, +6.1] and [+1.6, +6.0], 109 subjects). Every cell excludes zero. One caveat: the Swissmetro artifact carries no respondent identifiers, and its respondents answer repeated tasks, so the row-level interval may understate uncertainty.
"The paper does not report when this happens or how a practitioner would detect it before deployment, and I think it should." / "What predicts the Swissmetro calibration failure, and can it be detected in advance?"
We tested a diagnostic consistent with the proposed mechanism: a shift between the cross-fitted training/validation q distribution and the out-of-context deployment q distribution. Stage 2's correction is fit to the former; if it lands systematically off on the latter, the result is a bias, which would explain why the symmetric fixes you list cannot remove it, consistent with your reading. The FM's own q is well calibrated (uncalibrated ECE 2.2–2.4%), so the failure sits in the g-fit. We computed the detection statistic rather than asserting it: a two-sample KS on the max-class probability of q, validation vs test, per cell. The two Swissmetro cells show a significant shift (TabPFN KS 0.179, p ≈ 6e-23; Mitra KS 0.066, p ≈ 2e-3); LPMC and IoT show none (p ≈ 0.87–0.89; five of six cells have cached artifacts). The shift magnitude also ranks with the failure severity you cite (TabPFN 17.0% ECE vs Mitra 8.4%). The first check needs no labels on the deployment side; the second, held-out ECE after temperature fitting inside the validation split, does use validation labels. Both are heuristic warnings rather than proof of failure, and we will report them for all cells in the Discussion. If calibration is what matters and the alarm fires, the fallback is already built in: Stage 1 is the MNL, so switching off the correction gives back the MNL's calibrated probabilities without fitting anything new. The structural guarantees are unaffected either way; sign and ratio properties are calibration-independent.
"...it is rather incremental compared to the feature-augmented MNL baseline."
The comparison between those two is what Proposition 2 formalizes: feature augmentation gains more accuracy but its trade-off ratios drift up to 18× (1508 CHF/hr VOT on Swissmetro), and it explains why. The adapter is the same ingredient list with the one modification (two-stage, fixed-q) that provably removes the failure. We accept "combination of existing components plus theory"; the theory is the contribution. The new baselines make this concrete: the distilled MNL student keeps every guarantee and gains essentially nothing; TasteNet lands between MNL and adapter everywhere; among the evaluated baselines, the adapter is the only method combining these accuracy gains with exact population-level MRS preservation.
"What does the embedding of q provide over running the foundation model for prediction and the MNL for counterfactuals as two different models?"
One model you can audit, instead of two you have to reconcile. (1) One probability law: the two-model workflow produces two distributions for the same setting, and any pipeline that joins them (elasticities, welfare, share baselines) inherits their disagreement at the baseline point; the adapter answers both queries from one distribution. (2) The audit applies to the model actually deployed: in the two-model setup, the model serving predictions is the raw FM, the one that fails monotonicity and availability. (3) The one-distribution version of "use both," the convex ensemble αPMNL+(1−α)PFM, is in the paper: fitted α ≈ 0 wherever the FM is more accurate, so the blend collapses to the raw FM. Composition inside the utility is what gets the accuracy and the guarantee at the same time. We agree that under fixed-q the counterfactual derivatives match the MNL's; the gain over two models is coherence, not counterfactual content. And the calibration fallback above lives inside the same fitted model, so it does not sneak a second model back in.
We will revise the limitations section per your flags: the fixed-q boundary stated plainly with the measured frontier, the Swissmetro calibration entry expanded with the measured detection checks, and the accuracy framing corrected as above. Thank you again; your numerical check of Proposition 1 and the deployment question sharpened the paper's boundary into something we could measure. We are happy to run further checks during the discussion window.