- Rating
- 5
- Clarity
- 3
- Confidence
- 1
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The proposed TACT-KV (Tri-Axis Cosine Transform for KV Cache) method aims to compress the visual KV cache in vision-language models (VLMs), particularly for volumetric inputs like 3D CT scans and videos. The core idea of this approach is - 1. Reshape the visual KV cache into a 3D tensor (slice × height × width), exploiting the spatial structure inherited from the vision encoder, 2. Apply a separable 3D Discrete Cosine Transform (DCT) to move into the frequency domain, 3. Allocate bits across frequency components using a reverse water-filling strategy (more bits to high-energy components, fewer to low-energy ones), 4. Compress with standard quantization.
Main contributions include:
- a theoretical proof for distortion gain of water filling algorithm over uniform bit allocation in terms of spectral concentration of the cache
- a extensive evaluation covering six medical VLMs, two 3D CT benchmarks, and four general-purpose VLMs on Video-MME, establishing that TACT-KV is the only tested method that remains viable at 1-bit quantization
Main strengths of this approach are - 1. No calibration data is required, 2. No learnable parameters, 3. Runs once for every layer per sequence in single forward pass.. 4. Text token remain in b16, only visual tokens are compressed. 5. The benefit of three-axis structural compression extends beyond medical imaging to video tasks.
Strengths and weaknesses
Quality The paper is technically sound in its core contribution. The pipeline reshape to volumetric grid, apply separable 3D DCT-II, allocate bits via reverse water-filling, quantize with scalar codebooks - is cleanly motivated and well-executed. The theoretical contribution (relating distortion gain to spectral flatness) provides principled grounding, though the authors are appropriately candid that it holds only in the high-rate regime and breaks down on smaller models at the lowest operating points. The evaluation breadth is a clear strength: six medical VLMs spanning 4B–32B parameters, two 3D CT benchmarks from different anatomical regions, and a cross-domain test on Video-MME. The 1-bit survival result is striking and well-supported. The detailed analysis on per-subtype 1 bit results and elaborate reproducibility statement is appreciated. However, I note that the tasks evaluated are primarily classification and QA — generation-heavy tasks (e.g., radiology report writing, detailed spatial localization) are absent, and these may stress the compressed cache differently. Additionally, the compute-memory trade-off is acknowledged but not profiled in detail: the added FLOPs from the codebook and inverse DCT path are mentioned but no wall-clock latency breakdown is provided, making it difficult to judge whether the 8× batch gain translates to proportional throughput improvement or is partially offset by per-token overhead. The comparison with baselines raises a minor fairness question: whether prior methods (designed for full KV caches or text-dominant settings) were applied to only the visual portion under identical conditions. The paper would benefit from a brief explicit statement on this point.
Clarity The paper is well-written and precise in its terminology. The experiments and limitation section is notably well-structured — each limitation is specific, falsifiable, and scoped. One area where clarity could improve: the conclusion states that the margin over 1D quantizers "widens as the input becomes more spatially coherent," which implicitly defines the failure mode (spatially incoherent inputs) without stating it directly. Since noisy low-dose CT and corrupted CTs due to motion are common in clinical practice, making this converse explicit would help practitioners judge applicability.
Significance The practical significance is clear and well-framed. The authors correctly identify that clinical sites typically operate on single-card or small-cluster GPUs, and that the visual KV cache is the dominant memory bottleneck for volumetric inputs. An 8× batch capacity improvement on a single 96 GiB card directly addresses a real deployment constraint. The calibration-free, parameter-free design removes adoption friction - a non-trivial consideration in regulated medical environments where retraining or fine-tuning introduces validation burden. The broader applicability to video (Video-MME) suggests the method is not narrowly specialized, though the authors rightly accept this as empirical rather than predicted by their volumetric motivation. The significance would be further strengthened by demonstrating performance on spatially diverse 3D modalities (MRI, PET) and generation tasks, but these are reasonable future work items and not the gaps that undermine the current contribution.
Originality TACT-KV is original not because it invents new math - DCT, water-filling, and quantization have existed for decades but because it notices something no one else did: the visual KV cache has a natural 3D shape (slices × height × width) that can be exploited for compression. Every prior method treats the cache as either a flat sequence or compresses along a single dimension. TACT-KV is the first to say: "this data came from a 3D volume, so compress it like one." That simple observation, paired with a principled bit allocation strategy instead of ad-hoc frequency truncation, is what makes it novel.
Questions
Have you evaluated TACT-KV on generation-heavy tasks such as radiology report writing or spatial grounding? If not, do you have preliminary evidence that the compressed cache retains sufficient spatial detail for these tasks? The evaluation is limited to binary classification. Do you consider this a fundamental limitation of the method, or simply an evaluation gap? What gives you confidence that 1-bit survival on classification extends to longer, more demanding generation?
Limitations
The authors have been straightforward about the limitations of their work - the theory gap at low rates, single modality validation only, compute trade-off and clincal positioning of this approach are all well described. They have explicitly discouraged the use of this approach as replacement of bf16 in safety critical applications.
Paper formatting concerns
The broader impact discussion should be in the main paper rather than supplementary as NeurIPS guideliness expect authors to address the potential societal implications alongside the main contributions.
Final justification
Thanks for sharing results on generation task like radiology report writing and wall-clock latency breakdown. I will stick to my previous recommendation of accepting the paper
We appreciate the thorough review and thoughtful feedback on our submission. We are grateful of the statements of "technically sound in its core contribution" and "the practical significance is clear and well-framed". In the following, we have provided a point-by-point response to all questions raised.
R1: We thank the reviewer for this insightful question. We provide direct evidence on radiology report writing, and address both parts below:
We evaluate the report generation task on a 300-volume CT-RATE subset. Table Q1 reports two sets of metrics.
Table 1.TACT-KV at 1 bit stays close to the bf16 reference and reproduces it token for token on 26% and 35% of volumes, and its agreement with the ground truth is indistinguishable from that of the bf16 reference. KIVI at the same rate retains about half that agreement on MedGemma 1.5 4B and collapses on Hulu-Med 7B.
This is an evaluation gap rather than a fundamental limitation. 1-bit survival extends to longer, more demanding generation because the compressed state is fixed at prefill and tokens produced during decoding are stored at bf16, so generation length does not add compression error.
Table Q1: CT-RATE findings generation (N=300 volumes, greedy decoding, 180-token budget). "Identical" is the fraction of volumes whose generation matches the bf16 reference token for token.
R2: We thank the reviewer for this point. As requested, we provide wall-clock latency and throughput at the operating points of
Table 6.Table Q2(a): decoding throughput at the maximum batch sizes of
Table 6.Table Q2(b): decode step latency at the maximum batch size of bf16.
R3: Thanks for pointing out this fairness concern. We confirm that in our study prior methods were " applied to only the visual portion under identical conditions". Every backend compresses the visual portion of the cache only and holds the non-visual tokens at bf16. The shared visual prefix is prefilled once and reused across methods, and the slice budget, preprocessing and prompt are the same for every method and every bit budget, so the quantization step is the only factor that differs between them (
Appendix C.2). We will state this explicitly in the main text.R4: We thank the reviewer for pointing this out, and we provide more explicit clarification:
Theorem 1. The gain of reverse water-filling over uniform allocation is 1/γ, where γ is the spectral flatness of the transformed cache. A spatially coherent volume concentrates the cache energy in a few low-frequency components, so γ is small and 1/γ is large. Noise and motion spread that energy across the spectrum, γ approaches 1, and the gain approaches unity.We thank the reviewer for pointing this out. We will move the broader impact discussion from
Appendix HintoSection 4, alongside the limitations already stated there.