- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
This paper studies the problem of sequential knowledge acquisition in medicine with LLMs. The authors introduce MOBAYES a framework to separate the understanding of the clinical information of the patient from the reasoning about the likelihood of medical decisions. Their framework is not tied to a particular LLM architecture and displays strong performance in clinical diagnosis tasks with reduced costs compared to LLM only baselines.
Strengths and weaknesses
Strengths
Bayesian systems for medical diagnosis using LLMs are a promising and important direction for medical research. The authors demonstrate the performance and cost-effectiveness of their performance on several backbone LLMs. The paper is largely well-written with informative figures and tables.
Weaknesses
While I appreciate the authors intention in highlighting the performance of their model against strong frontier models in Table 2, I feel like it is necessary to include the results for the same models as MOBAYES to isolate the effect of the framework better.
The idea of separating the probabilistic reasoning from the language interface was already introduced in ACTMED (Ruhrberg Estevez et al. NeurIPS 2025) which should be discussed in the introduction and related works sections. The contribution claims regarding the novelty of this aspect need to be changed accordingly.
The datasets used are very small.
The ability to only diagnose diseases that are in the training corpus appears like a major limitation compared to the attractiveness of zero-shot diagnosis with LLMs in other frameworks.
The framework appears to mainly extract features from text and then using Bayesian statistics afterwards which in itself is not very novel. Can the same extraction be used for a downstream model e.g. XGboost with median imputation and if so can the authors please benchmark against this.
Questions
Would it be possible to evaluate the effectiveness of their method on VivaBench (Chiu et al. 2025) which is larger than AgentClinic and designed specifically for sequential diagnosis.
Could the authors please provide more details on the experimental setup in Table 1 since it is not referenced in the text.
Does the AgentClinic-MedQA 50/100 mean that the method was only run on a subset of the dataset? If so how were these patients chosen and why was the full dataset not used.
How is the soft-evidence probability implemented for real-world patients? Also, do baselines receive comparable information?
Can the authors benchmark against other bayesian diagnosis LLM frameworks such as ACTMED.
Can the authors please provide a sensitivity analysis on the number of diseases already present in the knowledge corpus on the diagnostic accuracy of the system.
Limitations
Yes
Paper formatting concerns
None
Final justification
I thank the authors for running the additional experiments, please include them in the final version of the paper. I personally feel this paper sits very much at the borderline and I am uncertain whether to give it a 3 or a 4. However, since most issues were addressed well in the rebuttal and the other 2 reviewers voted accept I will raise my score to 4. There are however a number of remaining limitations that should be discussed extensively in the limitations section.
Response to Reviewer zMZn
We thank the reviewer for the careful review. For clarity we number the weaknesses (W1–W5) and questions (Q1–Q6) in the order they were raised. The main concern, raised as both W2 and Q5, is originality in view of ACTMED, and we address it first. While both works combine probabilistic reasoning with language models, they belong to different architectural paradigms: ACTMED is a Bayesian Experimental Design (BED) framework, whereas MoBayes enforces a strict separation between language understanding and probabilistic reasoning. We then answer the reviewer's remaining points in order.
A clarification regarding ACTMED and the novelty of our work
ACTMED is an application of Bayesian Experimental Design in a clinical setting. The seminal paper in this line of work is BED-LLM, which predates ACTMED and establishes the mechanism of guiding an LLM with a Bayesian harness. We discuss BED-LLM prominently in our related works section within the hybrid category of our taxonomy (Section 2 and Figure 1a, also in Appendix D). The defining characteristic of this family is that the LLM sits inside the probabilistic reasoning engine. It serves as an oracle that generates patient-state distributions and supplies likelihoods that factor into belief updates.
Our work presents a fundamentally different approach: the LLM serves purely as a language-driven interface. It verbalizes questions and parses responses, but does not participate in the factorization of evidence or next-question selection. We instead rely on a strict separation between the LLM and a Bayesian reasoning engine whose priors and likelihoods are provided by a modular knowledge base.
This knowledge base can be learned from population statistics and/or curated by domain experts. In a hybrid system such as BED-LLM or ACTMED, the LLM fulfils the role of this knowledge base by suggesting probabilities on the fly. This leaves the system vulnerable to hallucinations, ungrounded probability estimates, and extrapolation outside diagnostic guardrails. The public discussion of ACTMED acknowledges this limitation: the reported gains vanish with a 7B open model, and with LLaMA-3.3-70B the sampler produced near-identical draws across prompts and temperatures, which the authors describe as leaving the method inoperable. By comparison, a tiny, inexpensive sensor model is sufficient to drive MoBayes and match or exceed frontier standalone doctors (Table 2; Appendix C.1).
We agree that ACTMED should be cited as a representative medical application of the BED-LLM lineage, but we do not see it as a close competitor.
W1. Extending Table 2
We thank the reviewer for this excellent suggestion. Table 2 currently compares a large standalone model from each family with a smaller sibling used as the MoBayes sensor, for example GPT-5.4 versus GPT-5.4-nano + MoBayes. This asymmetry is deliberate. It hands the autonomous baseline the capacity advantage, so that a MoBayes win cannot be attributed to model size. Despite this handicap, the smaller model coupled to MoBayes performs better, at substantially lower cost.
Following the reviewer's suggestion, we additionally evaluate the model-matched pairings, the small model as a standalone doctor and the large model as a MoBayes sensor, under one identical protocol (DDxPlus PatientSim). For two representative families:
Small standalone models perform worst; larger standalone models improve but remain below MoBayes; and MoBayes with either the small or the large sensor performs best. The gap between the small and large model also shrinks sharply within MoBayes, to within sampling noise (the two sensors' confidence intervals overlap), supporting the conclusion that the reasoning architecture, rather than scale alone, drives the improvement. The configurations shared with Table 2 reproduce their published values within confidence intervals, so the grid is consistent with the paper. We will add the complete matched table, with confidence intervals and token costs, to the revision.
W3. Dataset size
As each case is a complete multi-turn consultation rather than a static QA item, cohort sizes in the literature are correspondingly modest: AMIE evaluates 149 OSCE scenarios, and MEDDxAgent samples 100 patients per dataset. Our headline comparison likewise uses 100 patients per benchmark. While increasing the dataset size beyond the field standard is a target of future research, we report every headline result with a 95% confidence interval. MoBayes's gains over the strongest baseline in each column are significant under a paired bootstrap test (p < 0.05; Table 1; 95% CIs in Appendix C.13). The findings are reproduced across three benchmarks, two patient simulators, multiple model families, five patient personas, and different knowledge-base sources.
W4. Closed corpus versus zero-shot diagnosis
The closed-world setting confers no unfair advantage. Our closed-world baseline receives the identical candidate set, yet its gap to MoBayes does not close. The evaluations use published benchmark disease universes rather than a disease set constructed by us. We agree that MoBayes cannot diagnose diseases absent from its knowledge base. In a high-stakes setting, however, principled abstention may be preferable to an unvetted open-ended diagnosis. In our target-removal experiment, deleting the correct disease generally prevents MoBayes from crossing its commitment threshold, causing it to abstain rather than fabricate an in-scope answer. By comparison, a hybrid framework would solicit probabilities from an LLM oracle even for rare, unexpected, or confusing evidence. In deployment, the modular knowledge base allows practitioners to integrate new medical knowledge and define the LLM's diagnostic guardrails. Reliably applying a targeted knowledge update to an LLM-based probability surrogate remains an open research question.
W5. Extraction plus Bayes; XGBoost
An XGBoost engine would be a modular variant of MoBayes, not a competitor: the diagnostic engine is swappable by design. Feature extraction is only one component; MoBayes also maintains the disease posterior, incorporates soft evidence, selects questions using expected information gain (EIG), ranks the differential, and decides when to commit or abstain.
EIG requires a generative model P(feature∣disease) to anticipate answers to unasked questions. XGBoost instead models P(disease∣features) over a completed vector, so an interactive implementation would need our EIG mechanism or another active-feature-acquisition policy. It also requires labelled training rows, which exist for the empirical DDxPlus KB but not the LLM-elicited setting, where MoBayes runs unchanged.
We deliberately use naive Bayes as the simplest sufficient engine. That it suffices is part of the finding.
Q1. VivaBench
We thank the reviewer for the suggestion and will cite VivaBench. It evaluates six standalone frontier LLMs rather than the diagnostic-dialogue systems compared in Table 1. Its interactive protocol includes a dedicated investigation-ordering stage (laboratory and imaging), an action space outside our history-taking setting. We therefore view VivaBench as complementary and will discuss it as future work.
Q2. Table 1 not referenced in the text
The reviewer is correct. A stale cross-reference pointed to an appendix copy of the comparison, leaving Table 1 itself uncited. We will fix this.
Table 1 is our headline comparison across three benchmark settings. It reports Top-1 accuracy, selective accuracy, coverage, DHS, and tokens per case. MoBayes commits when its maximum posterior exceeds τ∗ and otherwise abstains. Per-system protocols are in Appendix C.14, with bootstrap confidence intervals in Appendix C.13. We will summarize this setup immediately before the table.
Q3. AgentClinic-MedQA 50 and 100
These labels refer to fixed subsets of the 213-case pool. Cases are selected with a fixed seed and weighted by disease frequency; ties are resolved randomly. DDxPlus cases are stratified across diseases. Every system uses exactly the same patients, so comparisons are paired and subsets are not selected separately for different systems. The headline comparison and significance tests use 100 patients; the more expensive model comparisons and ablations use 50. The 100-patient evaluation combines two independent 50-patient samples whose conclusions agree. Running every system and ablation on all 213 cases would require costly multi-turn simulations. This follows prior interactive work, including MEDDxAgent’s fixed-seed sample of 100 patients per dataset. We will clarify this procedure and rationale.
Q4. Soft evidence and information parity
Soft evidence is the parser's confidence over five ordinal labels, read from the patient's own hedging language (Section 3.4). It is not privileged information and works identically for real patients because the labels derive from what the patient says. All systems receive the same utterances, and standalone baselines read the full raw dialogue, a superset of the structured triples our parser extracts.
Q6. Sensitivity to the number of diseases
We ran precisely this analysis. The Disease Scaling Analysis (Appendix C.11) sweeps random DDxPlus subsets with different numbers of diseases (one patient per disease; three seeds). MoBayes Top-1 accuracy remains in the high 70s to mid-80s with no systematic decline as the candidate space grows fourfold. The standalone doctor remains between 34 and 41 throughout. The MoBayes advantage is therefore large and stable.