- Rating
- 5
- Clarity
- 4
- Confidence
- 3
- Originality
- 4
- Quality
- 3
- Significance
- 4
Read review
Summary
This work addresses medical illustration generation, arguing that this problem is not a simple text-to-image generation but a more complex reasoning task where visually plausible outputs may still contain anatomical or procedural errors. Authors introduce MedIGen, a unified multimodal (text + image) model built on Janus-Pro that replaces one-pass image generation with an interleaved refinement of the generated images through self-reflection. The model is trained through three stages: pretraining on 1.21 million medical illustration-caption pairs, supervised mixture training over generation, self-reflection, and re-generation skills, and GRPO-based reinforcement learning with dual-level rewards targeting both generation quality and image understandability. In addition, the authors introduce IlluGenBench, a benchmark containing 296 medical illustration tasks and 9,015 rubric criteria generated with GPT-5.1 and refined by experts. Experimental results show substantial improvements over a wide variety of open-source generation and reasoning models, with MedIGen achieving the best reported performance on IlluGenBench.
Strengths and weaknesses
The paper tackles an interesting problem, correctly identifying that visually convincing outputs may still be medically invalid, and the proposed introspective refinement framework is well thought of. The idea of explicitly coupling generation with self-reflection and corrective re-generation fits well with unified multimodal architectures. The three-stage training pipeline and the benchmark creation are equally significant and well-motivated, with IlluGenBench addressing an important evaluation gap by moving beyond generic text-image alignment metrics and introducing expert-guided rubric-based assessment focused on medical correctness. The empirical results are generally strong. MedIGen substantially outperforms its Janus-Pro base model and achieves large gains over other open-source baselines on the proposed benchmark despite not reaching the performances of commercial models. The stage-wise ablations support the value of each training component, while also presenting interesting results about failure cases, inference efficiency and cross-category analysis, supported by an extensive appendix. Authors also provide evidence that the model's main remaining bottleneck lies in converting identified errors into successful visual corrections rather than error detection itself. Several aspects, however, weaken the strength of the claims. Related to previous acknowledgment of the bottleneck, authors repeatedly emphasize reliable generation, but performance remains relatively weak on disease illustrations, with the expert audit showing that re-generation overall frequently fails even after successful error detection. Thus, the improvements are relative rather than robust medical correctness guarantees. Moreover, IlluGenBench, the rubric generation pipeline and the automatic evaluation protocol are all introduced by the authors. Although expert involvement is described and human agreement with the judge is analyzed, the paper remains dependent on an MLLM-as-judge framework and a benchmark construction process that may share biases with the proposed methodology. Independent validation on existing medical image-generation benchmarks or broader external evaluation would strengthen confidence in the reported gains. The contribution of the RL stage also appears limited in the main benchmark metric (+0.03 absolute improvement). While justified in the appendix, the main paper would benefit from a clearer demonstration that the dual-level reward design itself is necessary. Some other methodological details would also benefit from a stronger discussion, such as quality and diversity of the 150K supervised trajectories.
Questions
Additional evaluations on external benchmarks or datasets should be provided to demonstrate that the observed gains generalize beyond the proposed benchmark. Can the authors provide a stronger ablation comparing no RL, standard image-level RL and dual-level RL (proposed)? This would clarify whether the proposed reward decomposition is responsible for the gains. Is there a specific failure pattern over the failure cases for the disease images? Is there evidence that suggests that further reflection iterations would solve? Since GPT-5.1 is involved in generating captions and initial rubric criteria, how sensitive are benchmark results to rubric wording? I think the paper would benefit from proving that results are not overly dependent on benchmark generation.
Limitations
The authors discuss several limitations, including weaker performance on disease illustrations and the gap between error detection and successful correction, but the paper could more explicitly discuss limitations related to benchmark construction, dependence on the MLLM-as-judge framework and potential bias introduced by AI-assisted rubric generation. These should be acknowledged more clearly.
Paper formatting concerns
No major formatting, anonymity, or policy violations were observed. The paper appears compliant with standard submission requirements.
Final justification
The rebuttal addressed most of my concerns. Therefore, I believe with the proposed revisions the paper is ready for acceptance.
We sincerely appreciate your valuable feedback. Below, we address each concern.
AW1: We agree that the improvements are relative rather than robust medical correctness guarantees. We will revise the manuscript to clearly scope “reliability” to improved biomedical correctness and error correction under the evaluated benchmark settings.
AW2&Q1: We additionally evaluate on the independently constructed Biology subset of TechImage-Bench [1] (318 tasks, 2,772 criteria). We follow its official evaluation and report Rubric Accuracy and Criterion Score.
Observation. MedIGen improves substantially over Janus-Pro-7B and remains stronger than Qwen-Image-2512 on both metrics, while Gemini-3-Pro-Image remains the strongest model. This external evaluation shows that MedIGen's gains generalize beyond IlluGenBench.
[1] TechImage-Bench: Rubric-Based Evaluation for Technical Image Generation
Answer: We agree that the improvement from Stage 2 SFT to Stage 3 RL is modest in the main benchmark metric. This is consistent with the intended role of Stage 3: it serves as a final refinement step on top of an already strong Stage-2 model, rather than the primary stage for acquiring medical knowledge.
To clarify whether the dual-level reward design is necessary, we add a controlled ablation. All settings use the same Stage-2 checkpoint, training data, evaluator, and optimization budget. Image-level RL uses only generation-quality rewards.
Observation. Image-level RL provides only a small gain over no RL (+0.0074 Avg.), whereas dual-level RL yields a larger additional improvement (+0.0224 Avg.) across all three dimensions. Since the understanding reward is the key additional component, this ablation shows that image-quality optimization alone does not account for the Stage-3 gain.
The contribution of Stage 3 is also clearer in direct human evaluation.
Figure 8shows visibly improved medical correctness after RL. In a blinded expert study on the same prompts, the Stage-3 model is preferred in 64% of cases, compared with 19% for the Stage-2 model.We further report the First-Pass Rate, defined as the fraction of prompts for which the model produces a satisfactory image and correctly accepts it without requiring re-generation. It therefore measures both immediate generation quality and the model’s ability to avoid unnecessary refinement.
Observation. RL increases the First-Pass Rate from 64% to 80%, enabling 16% more prompts to succeed after a single generation without additional re-generation cost. This indicates improved alignment between generation and self-evaluation, with refinement focused on harder cases.
We will move these results to the main paper to more clearly demonstrate the necessity and practical value of the dual-level reward design.
AW4: The 150K samples form a supervised mixture: (1) approximately 138K filtered text-to-image samples and (2) over 12K generate–reflect–refine trajectories.
(1) Filtered text-to-image samples (~138K). These samples are selected from the 1.21M-pair IlluGen-Image corpus through multi-stage filtering for file validity, resolution, source reliability, watermarks, medical relevance, diagrammatic structure, educational value, and overall visual quality.
(2) Generate–reflect–refine trajectories (>12K). The trajectory instructions are constructed from more than 15K MeSH-derived biomedical concepts and expanded into detailed medical illustration requests. The instructions have a mean length of 273 words and a median length of 251 words. Each trajectory contains an initial generation, an image-specific reflection, and a targeted refinement.
The two experts achieve a Cohen’s κ of 0.87, indicating strong annotation consistency.
The reflections also cover diverse and complementary error types. Because a trajectory may contain multiple errors, these categories are analyzed using multi-label annotation:
Together, the 138K text-to-image samples provide broad and high-quality medical visual knowledge, while the 12K+ interleaved trajectories provide diverse process-level supervision for identifying and correcting image-specific medical errors.
We will incorporate these composition statistics, quality-audit results, diversity analyses, and representative trajectory examples into the revised manuscript.