- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 2
Read review
Summary
- IMC data is different from natural images as each image can have a variable number of markers. This breaks the traditional ViT and other image modeling backbones
- The authors introduce marker-adaptive hyper convolutions so a single encoder can encode a subset of markers from the ones used in pretraining without retraining.
- Evaluations span virtual staining, cell typing, clinical prediction, and inference efficiency
Strengths and weaknesses
Strengths:
- The hyperconvolution hypothesis is a distinct and genuine idea that is argued well theoretically in Appendix A.17 saliency index, which provides a mechanistic reason for why hyperconvolution may work.
- The efficiency results provided are strong, with an order-of-magnitude reduction over other baselines while improving accuracy.
Weaknesses:
- The hyperconvolutions, which theoretically are a good idea, become the biggest practical weakness of the method. The authors modeling choices necessitate a fixed learnable lookup table, which means that the model cannot predict markers unseen in training. As new markers are created by scientists who will use such models, a closed vocabulary becomes the biggest weakness and will require retraining from scratch even if one new marker is added. This weakness makes the claim of "foundation model" unrealistic for this study and needs more transparent framing in the text.
- The zero-shot terminology used in the study refers to held-out cohorts, but the markers are still included in the vocabulary (see weaness 1), making the zero-shot claims somewhat overloaded. There is no unseen marker generalization that the method can structurally perform.
- While EVA performs decently well across tasks in this study as well as in the original publication, its virtual staining MSE of 1.452 (2 orders of magnitude larger than authors' method) seems surprisingly high. I would encourage the authors to provide clarification here.
- Reason for not including KRONOS is unjustified. Other large studies like VirTues have been able to run KRONOS on IMC data without any retraining and have shown strong results, so the authors' justification of not benchmarking against KRONOS because they couldn't finetune it to IMC is weak. I encourage the authors to include KRONOS.
- Key baseline of mean marker missing. What happens if the authors simply take the average marker expression for each cell and apply a MLP or Pixie for cell phenotyping? Does this non-parametric baseline outperform their foundation model? Simple methods like mean marker expression and Pixie are the current gold-standard and are missing from baselines, weakening the claims of a "foundation model."
- There is limited out-of-cohort evidence. The main virtual-staining generalization claim rests on a single held-out cohort. I again encourage the authors to not claim having a "foundation model" if they cannot show robust performance in unseen independent cohorts (not just cross-validation on a single cohort).
- Even while testing in-domain, specifically on clinical prediction tasks, the gains are marginal (~1-2% sometimes). No significance testing is reported for patient level tasks and the cohorts are quite small to justify the trends.
- The takeaway from testing multiple families of models is unclear. Convolution is best on accuracy and efficiency but ViT is the fastest, so which one should a scientist use in their workflows?
The first weakness is structural in the study while 3-6 are open for investigation. Depending on the authors' response to the weaknesses, particularly 3-6, I would reconsider my score.
Questions
Please see weaknesses for questions and suggestion.
Limitations
Partly:
- The closed marker vocabulary is discussed only in an Appendix, and not in the main Limitations section of the paper, despite it being the central design tradeoff. The authors claim "foundation model" in the title of the paper, yet do not discuss this structural limitation in the main body of the paper.
- The generalization claim is based on a single cohort and not acknowledged as a limitation or future work. Any bias in clinical-prediction setting is also not mentioned.
Paper formatting concerns
N/A
Final justification
I thank the reviewers for adding new analysis and baselines. I have consequently increased my score.
We thank the reviewer for a direct and actionable review. Following the metareview's gradation of concerns we address Weakness 1 first, and we ran new experiments targeting W5 and W6, which the reviewer flagged as score-relevant.
We accept the framing on transparency: we will move this trade-off from App. A.5.1 into the main Limitations and qualify "zero-shot" as out-of-cohort throughout. On the substance, we should have been clearer about what ImmuVis does with an unfamiliar panel, as there are two paths and neither requires retraining from scratch:
PLM-based models offer a third path: predicting an unseen marker from its sequence embedding. Our objection is not that this is undesirable but that it is unreliable.
PLM-based vocabularies are also closed, just implicitly. VirTues and EVA cannot represent DNA1/DNA2 at all: no ESM entry exists. DNA is the most universally acquired IMC channel and the basis of segmentation; still, we had to exclude it to keep the comparison fair to VirTues (Sec. 4.3.1). Same for CD45RA+RO and panCK.
Where PLM transfer is structurally possible, it fails. With the same architecture and marker and only the embedding source differing, VirTues predicting AMY1A zero-shot from the near-identical AMY2A embedding (L2=0.154) gives MSE .96 vs .24 trained (App. A.5.1). CD45RA/CD45RO have near-identical ESM embeddings but expression correlation .35.
So the choice is not open vs. closed vocabulary but between a model that emits a biologically wrong reconstruction with no signal that it is unreliable and one that declines and asks for cheap adaptation. IMC staining feeds therapy-relevant readouts (PD-1, PD-L1, CTLA-4, ER, ERBB2).
How often does a genuinely new marker appear? Our 265-marker vocabulary, assembled from 25 panels across 28 cohorts, already covered 43 of the 48 markers on a fully external cohort (below). New panels are largely rebuilt from the same pool of validated antibody clones, and panel size is capped at ~40 markers by isotope interference (Sec. 1), so novel markers arrive slowly, each costing a frozen-backbone fine-tune, not a retrain. For scale, KRONOS2, released 27 July, ships a fixed 268-marker vocabulary with a documented procedure for adding unmatched markers: the same bounded-but-extensible design.
New results. Moldoveanu et al. (two panels; 48 markers, 43 in our vocabulary, 5 de novo) is absent from IMC17M but in VirTues' original corpus (App. A.3.1), which favours VirTues here:
Path 1 staining is not directly comparable (n/c): it averages the 43 in-vocabulary markers, not 48. Still, with zero adaptation ImmuVis outperforms the open-vocabulary model on cell typing for a cohort that model was pretrained on. This is, we think, the operational test of a foundation model: one checkpoint, no retraining, arbitrary panel subset, unseen cohort.
New: the wider set. Those two Moldoveanu panels are part of nine panels from 4 published studies, none in IMC17M. ImmuVis transfers to all nine (Pearson .41–.69), so the evidence is now the held-out SCCHN1 cohort plus 4 further independent studies, not one cohort.
Against VirTues
IMC17Mrestricted to the same marker subsets, under the paired Wilcoxon + FDR framework used elsewhere in the paper, ImmuVisSwin has lower per-image, per-marker MSE on 8 of the 9 panels (5 significant, 1 significant loss), and ImmuVisConv leads on panel-level Pearson on 6 of 9 (mean .577 vs .546). On the held-out SCCHN1 cohort the same test favours ImmuVis at q<.001. Downstream tasks on the three studies other than Moldoveanu need single-cell preprocessing we could not complete in the response window.Agreed this was a gap, and we ran it: cell typing on [Eling et al.], clinical on Cords and Danenberg. Cell embedding = mean marker-expression vector, no learned model:
For virtual staining the baseline is degenerate (it predicts the panel-mean image), giving MSE .387 against .057 for ImmuVisConv under the identical evaluation.
The reviewer is right that this baseline is strong: under either preprocessing it beats every VirTues variant on cell typing. ImmuVis still leads on every task. And, most relevant to the foundation-model claim, the mean-marker embedding has dimensionality equal to the panel, so it cannot transfer between cohorts with different panels, needs segmentation masks, and has no mechanism for virtual staining. It is a strong within-panel baseline, not a panel-flexible one, precisely the problem ImmuVis exists to solve. We will add it to the main tables.
A correction to the submission. The paper reports that EVA failed to converge on IMC17M; that is no longer accurate. We have since obtained stable convergence and are running the authors' own 50-epoch schedule, so we report no numbers from a run we have not validated. What does follow is that 1.452 reflects a released checkpoint evaluated outside its native preprocessing (EVA does not publish its IMC preprocessing; we applied ours as the closest match to the paper), not as EVA's capability.
Our justification is narrower than "we couldn't fine-tune it". KRONOS v1 encodes marker identity with sinusoidal embeddings over a marker index, so the assignment of markers to indices itself carries an implicit similarity structure. We could not derive a defensible assignment for 265 markers across 25 panels; multiple orderings, plus custom encodings and meshgrid coordinates, all diverged (App. A.9). Its corpus is fluorescence-based and its authors exclude ion-based modalities such as IMC.
Update, 27 July. KRONOS2 and CORAL were just released, after our submission and after the reviews, and they change this. KRONOS2 matches markers by name rather than by a derived ordering, and documents how to add unmatched markers from dataset statistics, which removes precisely the configuration problem we hit; CORAL loads both KRONOS versions behind one interface. We will attempt to run KRONOS2 through CORAL and report it in the revision.
Agreed, and we will not overclaim. There is a structural reason these endpoints are hard for every model: IMC images a small tissue region, while several endpoints are defined by information no section contains. Relapse depends on follow-up and systemic disease; grade and subtype are assigned from wider material. The ceiling is set by the information IMC carries, not by representation quality: the mean-marker baseline reaches .606 against .627 (best VirTues) and .641 (ImmuVisSwin), a ~3.5-point band.
New: we ran the tests you asked for. Paired Wilcoxon + FDR over the 10 folds, all 7 endpoints: no ImmuVis–VirTues difference is significant (all q≥.34; Cohen's d negligible-to-small). We will state plainly that on cohorts of this size ImmuVis is competitive with VirTues on patient-level endpoints rather than superior; the claims that do carry significance are cell typing and virtual staining (App. A.10, A.12).
A fair criticism of the presentation; we will add this guidance to the Discussion:
contextprotocol (.706 avg).ImmuVisConv's apparent weakness under that
contextprotocol was an artifact of embedding 8×8 crops with a network trained on 128×128 inputs; encoding the full crop once and pooling patch-aligned latent regions recovers .533 → .752, on par with ImmuVisViT (.759).We hope the new out-of-cohort and mean-marker results, and the clarifications on EVA and KRONOS, address W3–W6, and kindly ask the reviewer to reconsider their score.