- Rating
- 4
- Clarity
- 3
- Confidence
- 5
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
A federated learning framework, SynTeX-FL, is proposed in this paper for medical visual question answering. To bridge cross-modal heterogeneity, clinically meaningful textual representations are synthesized from medical images and modality-to-modality semantic transfer are performed without learning from paired multimodal samples. Modality-specialized LoRA modules is applied to improve representation learning across different imaging domains, and discriminator-based quality scores and source-aware weighting are employed to integrate heterogeneous client contributions.
Strengths and weaknesses
- The proposed approach is under the assumption that data from one imaging modality can be used to synthesize textual information to improve models for another modality. However, this assumption is questionable because different medical imaging modalities capture different anatomical and pathological information.
- Generating MRI-style or CT-style text from X-ray data is likely to produce text that is statistically reasonable rather than clinically grounded. X-ray reports, CT reports, and MRI reports are not different merely in writing styles. They correspond to different imaging physics and different observable findings.
- There is no ground-truth validation for the synthetic target-modality text. For example, when generating MRI text from X-ray data, the training process does not use paired MRI images or real MRI reports from the same patient as supervision. Cycle reconstruction only verifies whether the generated text can reconstruct the source-modality text, and the discriminator only judges whether the text resembles a medical report. Neither mechanism ensures that the synthetic MRI text reflects MRI-visible pathology accurately.
- There is a risk of clinical hallucination. The generated cross-modal text may appear medically reasonable but contain findings that are not supported by the source image. The paper does not sufficiently demonstrate that synthetic CT/MRI text generated from X-ray data is medically reliable or clinically meaningful.
- The necessity of synthetic cross-modal transfer is not addressed sufficiently. Since there are real CT clients and real MRI clients in the federated setting, a more natural approach would be to train CT-specific adapters using real CT data and MRI-specific adapters using real MRI data. The additional benefit of having an X-ray client generate MRI-style text for MRI adapter training is not clearly described, while this step adds noise and potential hallucination risks.
- The proposed method is closer to modality-specific federated learning than true multimodal federated learning.
Questions
-
Please justify why text synthesized from one modality(e.g., X-ray) can provide medically meaningful supervision for another modality(such as CT or MRI), given different imaging physics and observable findings. My evaluation score would improve if the authors provide evidence that the generated text is clinically grounded rather than only linguistically reasonable.
-
The current reconstruction and discriminator losses cannot validate whether synthetic CT/MRI text is medically correct. A small-scale expert review or clinical-label consistency analysis would help assess hallucination risk. My score would increase if the authors show low hallucination and high clinical consistency.
-
Comparison with modality-specific adapter baselines. The authors should compare against training CT/MRI-specific adapters using only real modality data without cross-modal synthetic text, which can validate whether synthetic transfer provides benefits beyond standard modality-specific FL.
-
Ablation on synthetic cross-modal text. Please report results without synthetic text, with only same-modality text, or with different weights of synthetic text. It can validate whether the synthesis module truly contributes to the gains or mainly introduces noise. My evaluation would improve if the gains remain consistent and stable.
Limitations
No. The paper does not sufficiently discuss the limitations and implications of relying on synthetic cross-modal medical text. In particular, the authors should explicitly describe the risk that generated CT/MRI-style text may be clinically reasonable but not supported by the source modality, leading to potential hallucinated findings. They should also discuss the lack of target-modality ground-truth supervision for validating synthetic text, and the possible negative impact of using such text in clinical VQA systems.
Paper formatting concerns
Figure 1 should be put after abstract.
Final justification
The authors' response addressed most of my concerns. More experiments were conducted to validate the proposed issues. I have raised my score. For my proposed concerns, currently they are verified via experiments. I hope more rational analysis will be explained to strengthen the contribution.
We thank the reviewer for questioning whether cross-modal synthetic text is clinically grounded despite modality differences and the lack of paired target-modality supervision. Please consider revisiting the Appendix in the Supplementary Material. Below, we provide our clarification on clinical validity, hallucination risk, and the contribution of synthetic cross-modal text.
Clinical validity and scope of cross-modal synthesis
SynTeX-FL is a training-time semantic augmentation framework that preserves source-supported evidence while reflecting modality-specific observability, rather than predicting reports for unobserved target-modality examinations. Because paired target-modality examinations are unavailable, we evaluate clinical finding preservation, modality-specific expression, and visibility constraints instead of reconstruction accuracy.
The qualitative results summarized in the table below, drawn from Figs. 3–17 in the Appendix, support this interpretation. The annotations in these figures were prepared based on clinician assessment: red arrows indicate the lesion or anatomical structure referenced in the report, red text marks clinically incorrect or inconsistent responses, and blue text marks clinically accurate and contextually appropriate responses. As shown in figures, SynTeX-FL preserves source-supported pathology while adapting it to the target modality.
For example, in Fig. 14, X-ray “bilateral fluffy infiltrates” are expressed on MRI as “bilateral areas of increased signal intensity,” which is physically plausible because pulmonary edema increases lung water content and may produce high signal on fluid-sensitive MRI sequences. The absence of cardiomegaly is also preserved, supporting the non-cardiogenic interpretation. In Fig. 8, the source MRI finding of “high T2/FLAIR signal” is represented on CT as “subtle hypodensities” in the same occipital and posterior parietal white-matter regions. MRI sensitively depicts white-matter abnormalities through changes in tissue signal intensity, whereas CT reflects differences in X-ray attenuation, causing the same process to appear as more subtle low-density changes. In Fig. 5, the source CT findings of “ground-glass” and “peribronchial consolidation” are represented on X-ray as “bilateral patchy opacities” and “peribronchial thickening.” CT provides detailed cross-sectional images of pulmonary abnormalities, whereas X-ray projects three-dimensional thoracic structures onto a two-dimensional image, causing the same process to appear as broader changes in lung opacity and bronchial contours.
Although paired target-modality scans are unavailable, these examples provide qualitative evidence that SynTeX-FL preserves source-supported findings while expressing them in forms consistent with the physical and diagnostic observability of each target modality.
We also quantitatively assessed whether the synthesized reports follow modality-specific reporting conventions using PPL (Appendix Table 10 and Fig. 1). For each target modality, PPL was computed using a GPT-2 evaluator fine-tuned only on real reports from the corresponding modality. A synthesized CT, MRI, or X-ray report was therefore evaluated against the terminology and reporting patterns observed in authentic reports of that modality. The evaluator measured how naturally each term follows the preceding clinical context, and lower perplexity indicates closer alignment with real modality-specific medical language. This result provides quantitative support for the clinical linguistic plausibility of the synthesized reports.
We will add the qualitative analysis and clarify the modality-specific interpretation of PPL in Appendix.
Clinical consistency and hallucination
We reported complementary evaluations of hallucination risk and clinical consistency using clinician-recommended sensitivity and PPV, which assess diagnostic completeness and the reliability of positive findings (Appendix Table 11 and Fig. 2; Main Lines 303–305). SynTeX-FL outperforms TST-CycleGAN on both metrics, indicating better preservation of source-supported findings with fewer unsupported additions.
To further evaluate hallucination risk and clinical consistency on LLaVA-Med, we assessed 996 source cases across five prespecified clinical label categories: primary finding, anatomical localization, imaging appearance, severity, and additional findings. The 996 source cases were approximately evenly divided among five clinicians. Blinded to the generation method, each clinician evaluated the original report and all corresponding target-modality reports generated by NAST, TST-CycleGAN, and SynTeX-FL for their assigned cases under the same protocol. The clinicians annotated their assigned cases by labeling each finding as present or absent in the source report and in each corresponding generated target-modality report. We also report on the visibility-violation rate as a visibility-specific hallucination indicator, defined as the proportion of generated positive statements that refer to findings not assessable in the target modality. Clinicians additionally labeled whether each generated positive finding was assessable in the specified target modality. Metrics were micro-averaged over the five clinical-label categories across all reviewed cases. As shown in the table below, SynTeX-FL consistently achieves strong performance across all metrics, indicating reliable preservation of clinician-annotated findings with limited omissions and unsupported additions.
For downstream VQA evaluation, clinician-identified findings were used as reference findings to assess finding-level correctness (Appendix Table 13; examples in Figs. 3–17). The results show that SynTeX-FL more consistently preserves clinically relevant findings in its VQA responses without omission or unsupported addition.
We will add the clinical-label consistency protocol, results, and analysis to Appendix D.
Real-only modality-specific LoRA and synthetic-text ablation
To isolate the contribution of synthetic cross-modal text, we examined different synthetic weightings in Appendix Tables 8 and 9. At γ=1.5, the model performs best on both datasets. The last row of Main Table 5 corresponds to the setting without cross-modal text, in which cross-modal synthesis and its associated modality-specialized LoRA are jointly removed.
Following the reviewer’s suggestion, we conduct a real-only LoRA ablation on the LLaVA-Med and VQA-RAD datasets, where each modality-specialized LoRA is trained exclusively on real data from its corresponding modality without synthetic cross-modal text. This directly implements the requested modality-specific adapter baseline. All training settings are retained while only synthetic cross-modal text is removed. As shown in the table below, SynTeX-FL consistently outperforms the real-only LoRA across all evaluated metrics. These results suggest that synthetic cross-modal supervision provides useful complementary signals beyond standard modality-specific training, rather than primarily introducing noise. We will add this ablation as an additional row in Main Table 5, with only the Modality-specialized LoRA component enabled.
LLaVA-Med
VQA-RAD
Taken together, the qualitative and clinician-based evaluations assess modality-specific observability, hallucination risk, and downstream VQA consistency, while the real-only LoRA ablation isolates the benefit of synthetic cross-modal supervision beyond modality-specific training.
We hope that the additional clinical evaluations, analyses, and ablation studies address the concerns raised. We will move Fig. 1 after the abstract and also welcome any further questions or discussion.