Summary
The authors propose CoRTeX, a recurrent neural network model designed to analyze fMRI activity by integrating timescale heterogeneity, positional priors, and dynamic Hebbian memory. By maintaining each region’s identity through its recurrent structure, CoRTeX allows for interpretability and aligns with known functional connectivity results. The authors evaluate the model on both resting-state disease and task-driven datasets, successfully classifying cognitive and clinical states with high statistical rigor.
Strengths and weaknesses
Strengths
-
A major strength of CoRTeX is its synthesis of various established biologically-motivated concepts. The model successfully integrates timescale heterogeneity with position-related information.
-
By leveraging a recurrent network to preserve identity, the authors have built a framework that remains interpretable and aligns with known results about functional connectivity.
-
The paper is statistically strong, utilizing appropriate tests in multiple places, such as DeLong’s and Hartigan’s tests, to validate its claims.
Weaknesses
-
A surprising result is the ablation effect of positional information. If positional information is so important in the classification task, the baselines should ideally also include positional information for a fairer comparison, especially since the paper focuses on finding region-level timescales.
-
Although models such as LSTMs have exchangeable hidden units, region information is maintained in the input space, meaning post-hoc XAI methods could theoretically extract region-specific temporal importance curves. The paper would be significantly strengthened by extracting temporal importance curves from the baseline LSTM and explicitly demonstrating why CoRTeX's architectural bottleneck yields a more biologically faithful timescale than post-hoc attribution.
-
The model’s primary objective is classification, meaning the extracted timescales might be task-specific artifacts rather than intrinsic regional markers (unlike the findings in the Hasson et al. and Honey et al. studies). This task-oriented design could also be dictating the choice of Mmax and contributing to the variations detailed in Appendix E.
-
Regarding diversity regularization: naive optimization could inherently represent another regime. The authors could justify this regularization by framing it as a way to match biological literature, but they must also evaluate its impact on performance. If forcing biological diversity hurts accuracy, it implies the biological mapping is at odds with the mathematical optimization.
-
Given that HRFs differ across regions, it is unclear how much these variations influence the resulting timescale ordering.
Minor Points:
-
Line 234: experiments “were” run
-
Lines 110-112 repeated in lines 93-95
-
Line 468: Extra comma after “e.g.,”
-
Figure 1: It would be better to explicitly mention what are the classification targets
-
Hasson et al. 2008 reference is duplicated
-
Remove models/init.pyc from codebase
Questions
-
Could the authors provide the number of parameters for the baselines, as that could affect the fairness of the comparisons?
-
While the detailed breakdowns in Tables A7 and A8 are appreciated and should be retained, I suggest adding supplementary summary tables. Providing the observed mean and variance (or the distribution of regimes) per Yeo7 network in these additional tables would greatly improve readability.
-
Suggestion: Given the limited data in COBRE, could the ABIDE resting-state dataset be added to help prevent overfitting? Specifically, introducing a loss term to match the functional connectivity distributions of control subjects across both datasets would act as a useful regularizer.
-
Suggestion: Could the model be used to predict subject identity, which could then be linked to cognitive traits, or reveal different timescales distributions for healthy controls versus diseased individuals?
Limitations
Yes. We commend the authors on critiquing their own work.
Paper formatting concerns
n/a
Final justification
I thank the authors for their detailed rebuttal and the additional experiments provided. The response successfully addressed my main concerns regarding the importance of positional information, regional HRF variability, and the clarification of several terms. Furthermore, although CoRTeX has a larger number of parameters compared to the baselines, evaluating based on validation performance ensures a fair comparison. I strongly encourage the authors to incorporate all promised changes and clarifications into the camera-ready version. Therefore, I am raising my score to 4.
(W1) Positional information in the baseline
Thank you for raising this. We provided the LSTM baseline with the same PE (one-hot ROI identity, NeRF-style coordinate features) used in CoRTeX. Because the LSTM does not contain an ROI-wise attention module, we evaluated three ways of incorporating positional encoding (PE) into its input: (1) concatenating the BOLD value at each time point with the one-hot and coordinate features and projecting the combined representation to one scalar per ROI; (2) projecting the PE to one scalar per ROI and adding it to the BOLD input; and (3) first compressing the PE to one scalar, concatenating it with the BOLD value, and projecting the result to one scalar per ROI. All projections used a shared nonlinear projection with normalization. For compactness, we report the best-performing PE variant among the three below.
Table F. Effect of positional encoding on the LSTM baseline.
Providing the same ROI encoding produces only a small improvement on NSD and does not improve the LSTM on ABIDE or COBRE. The parameter-matched control further indicates that the small NSD gain is not attributable solely to the additional parameters. Thus, positional encoding alone does not explain CoRTeX’s advantage; its benefit arises from how regional identity is coupled with persistent ROI-indexed states and identity-aware inter-regional communication.
(W2) Architectural interpretability versus post-hoc attribution
We agree that an LSTM preserves ROI identity at the input and can produce ROI-by-time attribution profiles. We therefore applied SmoothGrad to both models. Across all ABIDE and COBRE folds, however, the LSTM yielded highly similar temporal profiles across ROIs, with between-ROI variability reaching only 7﹣50% of a temporally shuffled reference. Under the same attribution procedure, CoRTeX showed substantially greater ROI differentiation, with a normalized between-ROI SD of 16.31% versus 4.07% for the LSTM. Thus, the LSTM attribution profiles did not separate ROIs sufficiently to provide clearly distinct region-specific temporal profiles.
Our claim concerns resolvability rather than biological fidelity. (M_r) reflects how CoRTeX allocates temporal integration across ROIs for the task. The contribution is that this allocation can be directly examined at the ROI level, whereas the LSTM attribution profiles do not provide comparable regional separation.
(W3) Neural validity and task specificity of learned timescales
We share this concern and tried to address it in §4.5 and §5, where we state that the observed regimes characterize fast variation within the trial and should not be conflated with the seconds-to-minutes hierarchy reported in prior work. M_r is learned under a supervised classification objective, and we do not read it as equivalent to the intrinsic timescales characterized by Hasson et al. and Honey et al. We will make the framing more explicit by describing M_r as a task-conditioned effective integration window, the number of recent timesteps each region's readout draws on, rather than an intrinsic regional marker.
On M_max the two settings differ. For task-fMRI, it is set to the length of the trial window, which is fixed by the trial structure rather than tuned for accuracy. For the longer resting-state series, it was selected empirically from the sweep in Table A6, so performance does enter that choice there. Removing the bound entirely is a direction we point to for future work.
(W4) Diversity regularization
To test this, we swept α_div over three orders of magnitude on NSD, where the timescale regimes analyzed in §4.5 are defined, with each seed reported separately and values averaged across the 8 subjects.
Table G. Diversity regularization sweep on NSD. ROI-SD is the standard deviation of M_r across the 360 ROIs, computed within each subject. macro-AUC is the test AUC macro-averaged over the 12 classes. Both are averaged across the 8 subjects, with seeds reported separately and α_div = 0.01 the operating point used for all three datasets.
Macro-AUC varies by less than 0.005 across the full range while ROI-SD more than doubles, so the imposed heterogeneity lies in a flat region of the objective rather than trading against it. We would not rest the justification on a match to the biological literature, however, and §4.5 already states that the term imposes no distributional shape. This follows from Var_r(M_r) being invariant under permutation of the ROI index, so the term encodes only that windows should differ across regions, without specifying which should be fast or slow. Since accuracy does not discriminate among settings, we did not select on it, and we use 0.01 unchanged across all three datasets (Table A5). By the invariance just noted, this value fixes the scale of separation rather than its spatial pattern. We will add the sweep as a new appendix.
(W5) Potential influence of regional HRF variability
Regional HRF variability is one of the motivations for the region-specific parameterization. We cite Handwerker et al. in §1 alongside the timescale literature, as evidence that a single temporal operator shared across cortex is a poor fit for fMRI, and CoRTeX is built to represent that heterogeneity rather than to remove it. M_r is accordingly defined on the BOLD signal, so any regional hemodynamic contribution is part of the quantity rather than a confound to be separated from it. This is why we describe it as a task-conditioned effective integration window in BOLD space rather than a pure neural timescale. We will state this explicitly. Separating the neural and hemodynamic contributions within M_r is a further question rather than a prerequisite for the claim as stated, and we will note explicit regional HRF estimation as a direction worth considering.
(Q1) Baseline parameter count
For the closest recurrent baseline, the LSTM sweep ranged from 0.143M to 47.673M parameters on NSD and from 0.102M to 47.008M on ABIDE and COBRE, exceeding CoRTeX in both settings (3.64M and 25.22M, respectively). To ensure that baseline performance was not constrained by model size, we swept all non-CoRTeX neural baselines over hidden dimensions ({64,128,256,384,512,1024}) and layer counts ({2,4,6}), with chunk sizes ({4,16,32,64}) additionally considered for Titans. Configurations were selected by validation performance. The resulting performance after this expanded search is reported in Tables A and B of our response to Reviewer GdMS. The selected sizes varied across datasets, and the best-performing configuration was not consistently the largest, indicating no monotonic relationship between parameter count and performance. The parameter counts for the neural and classical baselines are reported in Tables H and I, respectively.
We also corrected an error in the previously reported CoRTeX parameter counts. The correct values are 3.64M for NSD and 25.22M for ABIDE and COBRE. This correction does not affect the evaluated configurations or reported results.
Table H. Parameter counts of deep models (M).
Table I. Linear and kernel baselines. D is the input dimension. Ridge and logistic regression have identical coefficient counts.
(Q2) Yeo-7 network-level summary We have added a summary table of M_r by Yeo-7 network (Table J) while retaining Tables A7 and A8 as suggested.
Table J. Summary of learned per-region timescales M_r by Yeo-7 network on NSD. Values are computed over ROIs within each network, and variance is across ROIs. Per-ROI values are listed in Tables A7 and A8.
(Minor Points) Thank you for carefully identifying these issues; we will correct them in the revised manuscript and accompanying code.
(Q3) Suggestion 1
Thank you for this suggestion. We interpret it as using control subjects as a shared anchor, allowing the larger ABIDE cohort to inform typical connectivity for COBRE. We will consider a corresponding loss term to encourage a more general cross-dataset connectivity representation.
(Q4) Suggestion 2
Thank you for this valuable suggestion. Predicting subject identity would be more challenging because it requires subject-level rather than model-level timescales, but we believe it could be explored as a promising direction for future work.