- Rating
- 5
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
Model-Heterogeneous Federated Learning can be quite energy extensive. Thus, the authors hear propose two different techniques to reduce the energy consumption. First, building upon FedProto and leveraging score based pruning techniques, a method is proposed to prune channels based on prototype alignment loss. Second, leveraging alignment based technique for adjusting number of training epochs, as proposed in ALT, the authors incorporate energy consumption to decide how many epochs each client should train for. The empirical evidence suggest that the method results in a structured energy and performance trade-off.
Strengths and weaknesses
Strengths
- The paper is well presented and the methods is explained well.
- For evaluations, the experiments use actual energy measurements, instead of relying on proxies
- The motivation for the research is well established.
Weakness
-
The method proposed here is architecture specific, relying on having CNNs in the architecture. It's not clear how the method adapts if the fundamental architecture changes, for example transformer.
-
Statistical significance of results mentioned in the main section of the paper is not established. For example in Table 3, it's challenging to assess the statistical significance of the accuracy measurement.
-
The methods presented in the paper seems like adapting existing methods in the literature rather than being methodological innovations in themselves. For example, adding energy as a parameter to decide the amount of epochs to train for, appears to be an extension of ALT. Similarly scoring used to select which channel to prune, is a well established idea in literature and it seems like PASP core extension is to use the Protoloss instead of the cross entropy loss.
-
The authors mention that using actual energy measurements are quite important rather than relying on proxies such as Flops. However, no results are shared to establish that using flops as a proxy will result in non-optimized energy expenditure.
Questions
-
Related to W.1, can the authors provide how the method can be extended to architectures aside form CNN? Getting to know this will help understand how applicable the method is to other architectures and will help in improving the score.
-
Related to W.2, can the authors add standard deviation metrics to the main results to help make sure that the results are statistically significant. This will help establish the performance of the method beyond any doubt.
-
Related to W.3, can the authors please clarify why the techniques mentioned in the paper should be considered as methodological innovations, rather than mere adaption/extension of prior works? Getting more information here will help gauge the novelty/originality of the proposed methods.
Limitations
Authors do mention a number of limitations. However, it would be encouraged if the authors can discuss if the proposed method is limited to on certain architectures or if it can be generalized.
Paper formatting concerns
None that I am aware of.
Final justification
Prior concern was that the proposed method was not novel. Through the discussion, it seems like the method is not just an application of prior works and will require some careful choices and integration. In light of this discussion, I am willing to raise my score.
We thank the reviewer for the careful reading, for recognizing the clarity of the presentation, the importance of using hardware-level energy measurements rather than computational proxies, and the motivation of our research,as well as for the concrete, actionable questions. We address each weakness and question below.
W1 and Q1: Extension of PASI/PASP beyond CNN architectures
We thank the reviewer for this question. We clarify that the dependence on CNNs is an artifact of our current instantiation, not of the method itself. Below we describe the general formulation, the concrete transformer adaptation, why this adaptation remains prototype-friendly, and the experiment we are currently running.
General formulation. PASI requires only a scalar multiplicative gate gj attached to a structurally removable unit, scored as Sj=∣gj∣,∣∂Lproto/∂gj∣. The first-order justification (Proposition 1) uses only a Taylor expansion in the gate variable; no convolutional structure is involved. The batch-normalization scale γ is simply the gate that CNN architectures provide for free. EATS is architecture-agnostic as written, since it operates only on prototype alignment scores and measured energy, not on model internals.
Transformer instantiation of PASI/PASP. Transformers lack a BN-γ analogue: LayerNorm γ scales the shared residual stream, so pruning its dimensions in one layer would misalign residual additions across all layers and is therefore not a valid gate. Following the mask formulation of Kwon et al. (NeurIPS 2022), we instead attach explicit gates ml,hMHA=1 to each attention-head output and ml,iFFN=1 to each FFN intermediate filter. Since zeroing a gate is functionally identical to deleting the corresponding weight slices, the general score S=∣m∣,∣∂Lproto/∂m∣ applies directly; because m=1, it reduces to S=∣∂Lproto/∂m∣, estimated with the same B=5 forward--backward passes as Algorithm 1. PASP then physically removes the lowest-scored units: pruning head h excises its slice from WQ,WK,WV and the corresponding rows of WO; pruning filter i excises column i of W1 and row i of W2. This shrinks the actual GEMM dimensions executed on the GPU rather than masking them, preserving our central claim that only physical removal---not sparsity masks---yields measured energy reduction. A per-layer floor on retained heads replaces the max(8,⌊ng/4⌋) safety floor used for CNNs.
Why the adaptation remains prototype-friendly. First, the criterion is unchanged: importance is still the gradient of the prototype alignment loss, not the task loss, so a head that contributes little to local classification but shapes embeddings toward the global prototypes receives a high score and is retained---the exact property that motivates PASI, since the prototype space is the sole communication channel among heterogeneous clients. Second, the shared prototype geometry is preserved by construction: head/filter pruning shrinks only inner GEMM dimensions, while the residual-stream dimension d, the projection head hk, and the shared prototype space R128 remain untouched. Every client therefore maps into the identical prototype space regardless of its pruning level; pruning can affect only the quality of each client's embeddings, never the geometry of the shared space. In this respect the transformer instantiation is structurally stronger than the CNN case, where pruned channels feed the representation directly. Third, prototype-friendliness is directly verifiable in our framework: since EATS already computes the per-epoch alignment score qkt,e (Eq. 9), we monitor alignment before and after each pruning event and can verify empirically that PASI-gate pruning perturbs alignment less than magnitude or random baselines. We will provide the additional experiments regarding this question as soon as possible within discussion period.
W2/Q2. Variance estimates for the main results
We thank the reviewer for this suggestion. We repeated the main ablation using three random seeds, and the table below reports the mean ± standard deviation.
The multi-seed results preserve the qualitative trends reported in Table 3. Our combined method achieves the lowest mean energy consumption for all reported energy metrics. Compared with the FedProto baseline, it reduces total energy by 29.3% and E2A by 22.2%, 39.2%, and 37.5% at the 55%, 65%, and 70% accuracy thresholds, respectively. It also maintains comparable best accuracy, achieving 71.55 ± 1.02% versus 71.30 ± 1.35% for the baseline. These results indicate that the observed energy savings are consistent across the tested random seeds and are not limited to a single run.
In the revised manuscript, we will replace the single-run results in Table 3 with the mean ± standard deviation values. We will also report standard deviations and corresponding error bars for the other repeated experiments and figures.
W4. Energy Measurement and FLOPs
We thank the reviewer for highlighting this important point. We agree that the original manuscript did not provide sufficient empirical evidence explaining why FLOPs may be inadequate for energy-aware decision-making in model-heterogeneous FL.
To examine architecture-level differences while controlling for hardware variation, we additionally profiled six representative architectures using Zeus under the same hardware and measurement setup. The models are listed in ascending order of FLOPs per local epoch.
The ordering of measured energy consumption does not match the ordering suggested by FLOPs. In particular, the 3-layer CNN requires 17.2× more FLOPs than MobileNetV2-0.35, yet MobileNetV2-0.35 consumes 8.4× more energy per epoch (6.84 J versus 0.81 J). A FLOPs-based allocation policy could therefore incorrectly regard MobileNetV2-0.35 as substantially cheaper and assign it more local training, even though this could result in considerably higher actual energy consumption.
This mismatch also appears within the same model family. MobileNetV2-1.0 requires 5.1× more FLOPs than MobileNetV2-0.35 but consumes slightly less energy. Similarly, ResNet18 requires 30.8× more FLOPs than MobileNetV2-0.35 while consuming nearly the same amount of energy. These non-monotonic relationships show that FLOPs can mis-rank the actual energy costs of heterogeneous architectures. Such discrepancies may arise from differences in operator composition, kernel efficiency, memory-access behavior, parallelism, GPU utilization, and instantaneous power draw by GPU, none of which are fully captured by arithmetic complexity alone.
These observations support a central contribution of our work. Existing proxy-based approaches may estimate client costs using quantities such as FLOPs or analytical energy models. However, in model-heterogeneous FL, the relationship between these proxies and actual energy consumption can vary substantially across architectures. Consequently, minimizing a FLOPs-based cost does not necessarily minimize the energy consumed by the underlying hardware.
W3 and Q3, Concern of Novelty:
We agree these ideas have a long history; our contribution is showing they do not transfer to model-heterogeneous prototype-based FL, and resolving that gap. (1) To our knowledge, no prior work targets hardware-measured energy in fully architecture-heterogeneous prototype-based FL: FL pruning assumes a shared parameter space or a common global model; adaptive-epoch methods target latency or representation similarity, not measured energy, and do not support architecture heterogeneity. (2) The prototype-loss criterion is more than a loss swap: in this setting the prototype space is the sole communication channel among clients, and a channel can be task-redundant yet federally critical. Our theoretical analysis (Appendix D) shows task-loss criteria incur a strictly positive prototype-distortion gap whenever rankings disagree, and the criterion$\times$timing interaction, explained via drift-induced score error in the same appendix, is itself a new, transferable finding. (3) EATS differs from ALT in mechanism, not parameters: measured-energy profiling with EMA smoothing, system-level greedy allocation with a knee-point cutoff, and a convergence guarantee, which ALT does not provide.