- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper proposes MedGround-Bench, a causally-validated CXR-VQA attribution benchmark, and MedFocus, a concept-based causal attribution method. The problem is important and the framework is well-structured.
Strengths and weaknesses
Strenths: The faithfulness of visual attribution in medical LVLMs is directly tied to clinical trustworthiness, making the problem highly significant.
Weaknesses:
- Foreground intervention is too crude: The paper uses zero-masking to blank out the target region, which introduces severe boundary artifacts and out-of-distribution patterns. The model may react to the destruction of image quality rather than the absence of evidence. Moreover, the paper does not adequately compare against gentler alternatives such as healthy-tissue inpainting, cross-disease replacement, or severity-/scale-aware editing.
- Foreground/background dichotomy is oversimplified: Clinical reasoning patterns such as cardiothoracic ratio, bilateral lung symmetry, and trans-lobar/trans-organ cues cannot be captured by this binary assumption. The causal filter may systematically exclude cases where the model relies on multi-region evidence.
- Evaluation pipeline raises fairness concerns: All pixel-level saliency maps are converted to bounding boxes using a fixed 90th-percentile hard threshold, without adapting to the very different saliency distributions across methods. MedFocus, by contrast, directly outputs a concept-level bounding box, bypassing thresholding and connected-component analysis. This inconsistency undermines the claim that MedFocus is strictly superior.
Questions
-
Intervention design: Can the authors provide a comparative attribution study across zero-masking, healthy-tissue inpainting, cross-disease replacement, and fine-grained editing, to rule out the possibility that the model is responding to black-box artifacts rather than true semantic removal?
-
Multi-region and global cues: How does the foreground/background assumption handle diseases whose diagnosis requires simultaneous evidence from multiple anatomical regions or global cues (e.g., cardiothoracic ratio, bilateral symmetry, diffuse bilateral disease)?
-
Evaluation fairness: Would MedFocus remain superior if baseline methods used validation-set-tuned adaptive thresholds?
Limitations
Yes
Paper formatting concerns
No
Final justification
I thank the authors for their detailed response. Since my main concerns have been addressed, I recommend acceptance.
Thank you for the detailed and constructive review. Below we provide point-by-point responses to each of your concerns.
Thank you for the suggestion. We would like to first clarify that MedGround-Bench is constructed using RadEdit inpainting ("No [attribute]" / "No abnormality") to remove the target concept, rather than zero masking. For the MedFocus method, we use zero-masking and have compared it to healthy-tissue inpainting (RadEdit) in our Ablation Studies (Section 5.4), where zero-masking achieves better performance. Following your suggestion, we further add the cross-disease replacement intervention to this comparison. As shown below, MedFocus achieves the best IoU/F1 score with the zero-masking intervention, supporting the selection of zero-masking in our implementation.
To test whether the advantage of zero masking is driven by generic image corruption, we added a matched irrelevant-region control in which an equal-size region not containing the target concept is masked. As shown below, masking the target region produces a larger reduction in the answer probability than masking the control region. This result provides evidence that the response is primarily concept-specific rather than solely driven by the masking artifact.
During the benchmark construction, we do not impose a fixed diagnosis-to-anatomy mapping. Instead, the interventions are defined by the available human annotations rather than by a predefined anatomical lookup. For diagnoses requiring multiple regions, the intervention is applied to the union of the annotated regions. Such cases can therefore be retained when the combined edit changes the model's prediction, and the background edit does not. However, if the annotations omit relevant regions or fail to represent a global cue, the case may be excluded. This is a limitation of annotation coverage, which we will state explicitly.
To further quantify how often the diagnosis is based on multi-region evidence and whether they are effectively retained in the benchmark, we analyze the distribution of the region counts in the original ImaGenome data and the one in the retained questions in our benchmark. The results below show that multi-region cases are not underrepresented in the retained set. Cases with more than two annotated regions account for 27.8% of the source set but 44.7% of the retained set. One possible explanation is that single-region questions often require finer localized evidence, which may be more difficult for the evaluated models to identify and use reliably.
Following your suggestion, we conducted a validation-tuned thresholding experiment. Using 144 PadChest-GR training questions held out exclusively for hyperparameter selection, we tuned the quantile threshold separately for each baseline and model to maximize validation IoU. The results below show that the threshold tuning improves baselines. However, MedFocus continues to achieve the best performance, which does not require saliency-map thresholding.