- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper proposes PhysFlow, a training-free inference-time correction for flow-matching T2V samplers. It computes a latent flow residual that measures mismatch between predicted velocity and frame-to-frame latent trajectory direction, then applies a masked, clipped velocity correction plus a straightness prior during active sampling steps. The authors also introduce MotionStress-100, a motion-heavy prompt benchmark with VLM yes/no scoring. Experiments on Wan2.1 report modest but consistent gains over baseline and selected inference-time alternatives at roughly unchanged cost.
Strengths and weaknesses
Strengths:
First, the paper identifies a useful and underexplored intervention point for training-free video generation: the sampler velocity field. Most related inference-time methods modify CFG, attention, or optimize latents; PhysFlow instead directly regularizes the velocity predicted by a flow-matching T2V model. This is a clean design choice because the correction acts exactly where the sampler determines temporal transport.
Second, the latent flow residual is a plausible motion-failure diagnostic. It compares the predicted per-frame velocity with the local frame-to-frame latent trajectory direction, so it is naturally connected to artifacts such as object fragmentation, shape deformation, and temporal flickering. The residual-aware mask, safe clipping, and active schedule are also reasonable engineering choices: they let the method act where inconsistency is high while reducing the chance of damaging late-stage visual refinement.
Third, the method is practically attractive. It is training-free, requires no new network, and reports essentially unchanged inference cost. This makes the contribution more useful than a heavier test-time optimization method: even a modest improvement can matter if it is a drop-in switch for existing flow-matching samplers.
Weaknesses:
The main weakness is that the gains are small. The headline MotionStress improvement is around +3.7 absolute points, and the VBench motion-smoothness gain is also modest. This is acceptable for a zero-cost method, but it raises the evidentiary bar: uncertainty estimates, human calibration, and robustness checks become central to interpreting the result.
The method is still only demonstrated within the Wan2.1 model family. The 14B result is useful, but it does not establish cross-family generality. Since the motivation says similar motion artifacts appear in other T2V systems, a result on at least one non-Wan flow-matching backbone is important. This is especially important because the observed gain on Wan is positive but not large.
The dependence on sampling steps is under-quantified. The limitations say PhysFlow may fail under aggressive few-step distillation because the active schedule has too few steps to operate, but modern deployment often uses few-step samplers. A step-count and sampler sweep is needed to clarify the practical operating range.
Another practical weakness is the lack of released mp4 evidence. For a motion-focused T2V paper, static figures and aggregate metrics are not enough: reviewers need the actual videos to inspect temporal flicker, object fragmentation, motion continuity, and prompt adherence over time. The paper would be much easier to evaluate if it provided the generated mp4s for the main qualitative examples, paired-seed baseline comparisons, MotionStress samples, and representative failure cases.
Questions
Can you evaluate PhysFlow on at least one non-Wan flow-matching T2V model, such as CogVideoX or HunyuanVideo? This is the most important missing experiment, because the current improvements are positive but modest and all main evidence is within the Wan2.1 family.
Please report confidence intervals or significance tests for the MotionStress QA scores. Are the approximately +3.7 absolute points robust across prompts and random seeds, or are they driven by a small subset of examples?
Please provide more complete human-study details: number of unique raters, number of judgments per rater, compensation, rater-level aggregation, inter-rater agreement, and confidence intervals for the paired-seed win rates.
Limitations
Adequately addressed. The Limitations paragraph honestly notes failure under heavily-tokenized latents and aggressive few-step distillation (too few steps for the schedule), and that PhysFlow corrects sampler-induced inconsistency, not prompt ambiguity.
Paper formatting concerns
None
Final justification
As the rebuttal response mainly resolved my concerns, I will maintain my score (Borderline Accept).
We thank the reviewer for the valuable feedback. We are glad that the reviewer appreciates the contribution of our work. Below, we address the reviewer’s concerns one by one.
Q1: Generalization to a Non-Wan Backbone
We thank the reviewer for this insightful question. We evaluate PhysFlow on HunyuanVideo-1.5 and Wan2.2 using the same fixed hyperparameters as for Wan2.1, without backbone-specific tuning.
PhysFlow improves the average MotionStress score by +1.84 points on HunyuanVideo-1.5 and +4.45 points on Wan2.2. On HunyuanVideo-1.5, four of five categories improve, while Linear Motion decreases marginally by 0.55 points. These results provide direct cross-family evidence that PhysFlow transfers beyond Wan2.1 without model-specific retuning.
Q2: Statistical Robustness of MotionStress Improvements
We thank the reviewer for this valuable feedback. All comparisons are paired by prompt and random seed. We average the three paired-seed generations for each prompt and perform a paired bootstrap over prompt-level differences using 100,000 resamples. The prompt-level confidence intervals are shown below:
PhysFlow consistently outperforms the baseline on both MS-100 and MS-100-Ext, achieving average gains of +3.73 and +3.78 points, respectively, with both 95% confidence intervals excluding zero.
Q3: Human-Study Details
We thank the reviewer for requesting these details. We clarify each requested item below:
The preference margin is the PhysFlow-better rate minus the Baseline-better rate. Its confidence interval remains above zero for all three axes, with the largest margin on Motion Coherence. The high Both comparable rate, particularly for Text-Prompt Alignment, is expected because PhysFlow does not directly modify prompt semantics. The positive preference margins and inter-rater agreement support the human study as meaningful evidence of perceptual improvement.
We greatly appreciate your insightful and helpful comments, as they will undoubtedly help us improve the quality of our article. If our response has successfully addressed your concerns and clarified any ambiguities, we respectfully hope that you consider raising the score. Should you have any further questions or require additional clarification, we would be delighted to engage in further discussion.