- Rating
- 4
- Clarity
- 2
- Confidence
- 3
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
The paper proposes Sparse Multimodal Switching State-Space Model (S4M3), a method for analyzing joint scalp EEG-intracranial EEG recordings. The paper identifies three main challenges in analyzing such recordings: partial-observability, nonstationarity, and sparsity. S4M3 tackles each challenge by adding a switching capability and elastic-net sparsity penalty to the model. The paper derives an EM algorithm for inference and parameter estimation. S4M3 is compared with other methods on a synthetic dataset whose ground truth regime and dynamics are known, and is applied to a real EEG dataset.
Strengths and weaknesses
Quality: The submission is technically sound, with appropriate explanations throughout the paper. The methods section is particularly well-written in great detail, with supporting sections in the Appendix. The claims are well supported by experimental results, though I think the real data experiment could be improved with additional baselines (see Questions below).
Clarity: Although the paper is generally well-written, I think the paper needs a more concise abstract and Introduction, as they’re currently too dense. In addition, I think the paper would benefit from having a technical background section on switching models (e.g., switching linear dynamical system), elastic-net sparsity penalty, and other key techniques used throughout the paper. In addition, the Figure legends and labels are too small, making it hard to read.
Significance: The paper could be of interest to the community interested in EEG analysis, and it’s well supported by S4M3’s performance on synthetic dataset. However, the paper lacks comparison with other baseline methods for the real data experiment, which could make the community question the results for the real data experiment.
Originality: The paper lacks originality, as it mostly builds on top of existing methods, such as switching models and elastic-net sparsity penalty.
Questions
-
The paper currently shows the results from S4M3 for the real EEG-iEEG recording experiment. Although the authors make a note that the findings from S4M3 are interpretable and are in line with the clinical results, it’s hard to say whether this result was only possible because of the proposed method. How sensitive is the result to the hyperparameters of S4M3, and how are the hyperparameters chosen? In addition, could we apply existing methods such as the multi-population recurrent switching linear dynamical systems (Glaser et al. 2020 cited as [3] in the paper) and compare the results?
-
Could you further clarify the key contributions and novelty on top of the existing switching models?
-
(Minor) How efficient is the current S4M3 implementation? How well does S4M3 scale to larger EEG-iEEG datasets, with more timesteps, etc?
Limitations
Yes
Paper formatting concerns
No concerns.
Final justification
The authors addressed my questions and concerns with additional experiments and explanations. Thus, I raise my score to 4.
1. Strengths and Weaknesses
We thank the reviewer for recognizing the paper’s strengths. We address the real-data concern in Q1 and will shorten the opening sections, add brief methodological background, and enlarge figure text. As clarified in Q2, the contribution is unified estimation and assessment of sparse regime-dependent network contrasts under multimodal partial observation.
2. Questions
Q1. Expanded real-data evaluation, baselines, and sensitivity
We expanded the Patient #1 simultaneous EEG-iEEG analysis by comparing S4M3 with EEG-only and iEEG-only switching models, a prespecified 70/30 fixed-window dual baseline, and a multi-population rSLDS. We also performed 50-initialization robustness, elastic-net sensitivity, and source-resolution analyses. Directly comparable models use the same preprocessing, anatomically anchored N=12 source space, regularization, and select-refit-assess procedure. The clinician-confirmed SOZ (Hippocampus L; Hipp. L hereafter) was used only post hoc as an external qualitative reference.
Initialization robustness. Each switching model used 50 random initializations. A fit was valid if its final observed-data likelihood was finite and ρ(Φj)<1 for both regimes. The dual model produced 32 valid fits with median support 16.5 and a sparse distributed network. EEG-only produced 44 valid fits with median support 0 and no off-diagonal pathways; iEEG-only produced 14 valid fits with median support 32 and a denser mesial-temporal network. The fixed-window baseline produced a dense early-late contrast with support 58. The representative fit was the valid initialization with the highest observed-data likelihood.
Highest-ranked directed pathways. Pathways are ranked by absolute edge-level Wald statistic after unpenalized refitting; pBH is the BH-adjusted p-value, and Hipp. L indicates whether Hipp. L is an endpoint.
Modality and temporal baselines. The dual model produced a sparse distributed network with 3/5 top pathways involving Hipp. L. EEG-only selected no off-diagonal pathways; iEEG-only emphasized local Hipp. L–Amygdala L connectivity, and the denser fixed-window network had no top-five Hipp. L pathway. Thus, the dual model combined local intracranial and broader source-space information.
Comparison with multi-population rSLDS. rSLDS detected a sustained regime change at 1.548 s, supporting a nontrivial transition. However, its population-level latent coordinates are not anatomically indexed, so its dynamics cannot be mapped directly to specific sources or pathways. We therefore use rSLDS for regime detection, whereas S4M3 localizes pathway changes and assesses them statistically.
Elastic-net sensitivity. The nominal (λ,α) pair was selected by observed-data likelihood; neighboring values assessed sensitivity. We evaluated λ=(0.0005,0.001,0.002) and α=(0.90,0.95,0.98) with 10 initializations each. Results were more sensitive to λ. At λ=0.0005, 8–10/10 fits were valid and Hipp. L appeared among the top five in nearly every fit. At λ=0.001, 5–6/10 were valid but Hipp. L involvement persisted. At λ=0.002, only 0–1/10 were valid, indicating over-regularization. Median support decreased from about 28–31 to 16–19 as λ increased, whereas α had little effect. The Hipp. L-centered interpretation was therefore stable over the usable range.
Source-space resolution. We repeated the dual analysis at N=30 and 40. Hipp. L remained involved, appearing in one top pathway at N=30 and two at N=40. Exact pathways varied with anatomical granularity, as expected because each parcellation defines a different estimand.
Q2. Novelty and contributions beyond existing switching models
The novelty of S4M3 lies in combining anatomically anchored multimodal inference, sparse regime-specific network estimation, and post-selection assessment of cross-regime pathway changes.
Regime-specific anatomical networks as inferential targets. The primary estimands are the directed networks Φj and their contrasts, such as Δ=Φ1−Φ0. As summarized below, S4M3 jointly infers anatomically anchored latent sources, discrete regimes, and sparse regime-specific networks under one likelihood. It therefore identifies which directed pathways change across regimes, estimates the sign and magnitude of those changes, and ranks them after uncertainty and multiplicity adjustment.
Multimodal fusion under complementary partial observation. The multimodal contribution is not merely observation stacking. S4M3 links EEG and iEEG to the same anatomically anchored latent process through distinct modality-specific operators. EEG provides broad but spatially mixed coverage, whereas iEEG provides sparse, locally precise measurements. Their joint use can reduce modality-specific unobservable subspaces, as formalized below. This complementarity has a precise observability consequence.
Proposition 1 (Complementary multimodal observability). For regime j, let OEj and OIj denote the observability matrices associated with L and C, and define OEIj=[OEj;OIj]. Then null(OEIj)=null(OEj)∩null(OIj) and rank(OEIj)≥max(rank(OEj),rank(OIj)). Hence, the joint system is observable whenever the modality-specific null spaces intersect only at 0, even if neither modality is individually observable.
The result follows because OEIjv=0 if and only if both OEjv=0 and OIjv=0.
We evaluated this complementarity in a 30-trial coverage-stratified synthetic experiment. Edges were grouped by whether their source and target regions were directly sampled by iEEG (covered) or not (uncovered). For covered-covered edges, the dual model achieved F1=0.838, versus 0.719 for iEEG-only and 0.182 for EEG-only, with paired gain 0.139[0.090,0.195]. When only the source or target was covered, iEEG-only achieved F1=0, whereas the dual model achieved 0.367 and 0.363, with gains 0.207[0.129,0.290] and 0.340[0.233,0.451], respectively. The largest gains occurred when iEEG constrained one endpoint and EEG informed the other, directly matching the complementary-coverage mechanism described by Proposition 1.
Post-selection assessment of pathway changes. Existing switching models generally do not provide pathway-level assessment of cross-regime contrasts because their latent coordinates may not be anatomically anchored, their transition matrices are treated primarily as predictive parameters, or support selection is not separated from uncertainty quantification. Because penalization induces shrinkage bias, direct Wald testing of the penalized coefficients is unsuitable. S4M3 instead combines penalized support selection, unpenalized refitting, fixed-support large-sample Wald assessment, and multiplicity correction, yielding sparse pathway discovery with approximate evidence for regime-dependent change.
Q3. (Minor) Efficiency and scalability
The per-iteration cost is O(TJ2(N3+MN2+M3)+TJN2+JNs2), where J, N, M, and s≪N denote the numbers of regimes, latent sources, observed channels, and active coefficients per row, respectively. Runtime is approximately linear in T but more demanding in N because of latent covariance operations.
On a 64 GB CPU workstation, runtime increased from 734 s at N=20 to 1088, 1557, and 2455 s at N=40, 60, and 80. Edge F1 was 0.572 at N=40 and 60, decreasing to 0.500 at N=80. Thus, the implementation is practical for moderate source spaces, while high-resolution models remain the main computational bottleneck. Derivations and results are in Appendices C and H.