- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
RoMo Hands is an in-the-wild, text-paired pure-hand motion dataset (~542K bimanual sequences, 884 h, 95.5M frames @30fps), ~10× the largest prior pure-hand set. It extends the RoMo video pipeline with three hand stages: WiLoR bimanual MANO recovery + wrist-anchoring to SMPL-X; a detection-ratio + dexterity filter; and five-level captions (L0–L4) via Qwen3.5-27B under a 3-level taxonomy. It also proposes R_hand, a 393-D redundant bimanual representation, and benchmarks four body generators (MDM, Kimodo M, MoMask, MotionMillion) adapted to it under a semantic + physical protocol, finding no model dominates both metric families.
Strengths and weaknesses
Strengths:
Order-of-magnitude scale jump for text-paired pure-hand data; addresses a real bottleneck. Five-level caption hierarchy + taxonomy-stratified evaluation are richer than prior single-caption datasets. Type-aware normalization for R_hand is backed by an A/B comparison. Releases dataset, taxonomy, captions, TMR evaluator, and training configs.
Weaknesses:
Annotation quality is unverified. Both the hand poses (WiLoR monocular per-frame MANO regression) and the captions (VLM-only) are automated, yet neither is checked against ground truth or human evaluation. Critically, the two filters operate on action content — detection-ratio on visibility, dexterity on motion richness — not on extraction correctness: a confidently-detected but mis-estimated pose passes every filter. For a dataset whose headline is scale, the quality underlying the 884 h is unsubstantiated. Representation: no generation-side ablation of R_hand (393-D vs. rotation-only/201-D); the authors concede positions/velocities carry no information beyond rotations, so its benefit for hands is asserted by analogy, not shown.
Questions
- How is the accuracy/plausibility of WiLoR pose recovery assessed? Please provide any quantitative check (e.g., on a held-out ground-truth subset) or human validation, given that neither filter targets recovery correctness.
- Can a human study of caption fidelity be provided, at least on a sampled subset?
- Add a generation-side ablation: R_hand (393-D) vs. rotation-only/201-D, to show the redundant channels help on hands.
Limitations
Partially addressed. The paper notes the dexterity-filter selection bias, inherited demographic/geographic composition, and VLM-only captions, but does not confront the core issue: pose-recovery accuracy/plausibility is neither measured, human-evaluated, nor filtered, so the quality of a fully automatic pseudo-labeled dataset is unverified.
Paper formatting concerns
None.
Final justification
The authors have adequately addressed my main concerns by providing additional human evaluation and representation ablations, which improve confidence in the quality and usefulness of the dataset. Nevertheless, the core contribution remains the collection and organization of a large-scale hand-motion dataset using existing hand-tracking and reconstruction methods, rather than a substantial methodological advance in hand-motion recovery. The rebuttal strengthens the paper but does not materially change my overall assessment, so I will maintain my current score.
We thank the reviewer for the thoughtful and encouraging assessment, and especially for recognizing the "order-of-magnitude scale jump for text-paired pure-hand data" that "addresses a real bottleneck." Both weaknesses raised are also raised by Reviewer 4twm, so we answer them in full here.
1. Representation ablation: does Rhand help over simpler representations? [Q3-Gnnu; Q3-4twm]
Comparative experiment. We are running the requested experiment. The setup is exactly that of Table 2: the same $\sim$461K-clip training split, each architecture held at its published per-model configuration, identical epoch budgets, same text encoder, AdamW optimizer, and the same type-aware normalization (see the setup note at the end of this section for full details). Only the representation changes: raw MANO, CLUTCH, and full Rhand (393-D), each evaluated on MDM, MoMask, and Kimodo. Every variant is decoded to a common space and scored by the same frozen TMR evaluator, so the differences reflect the representation and not the metric.
Results so far. For now, only MoMask has completed training. The MDM, Kimodo, and MM training runs are still in progress and will be reported as they finish.
The results show that full Rhand is best on every metric. The two baselines are both rotation-only and land close to each other despite differing in dimensionality and rotation format, which points to the missing position, velocity, and heading channels as the source of the deficit rather than the details of the parameterization. The advantage also holds on the distribution-level metrics and not only on retrieval, so the redundant channels improve the generated distribution itself rather than just text alignment.
On the design intent. Rhand follows the standard practice in body-motion generation of adapting the raw parametric pose for generative architectures: HumanML3D-263 [7] and MotionStreamer-272 (Xiao et al. [37], adopted by MotionMillion [4]) wrap the body skeleton in redundant position, velocity, and heading channels, and it is that redundancy that makes them effective for continuous generators. CLUTCH [31], the closest bimanual precedent, adopts only the 6D rotations and a per-hand root translation, without heading canonicalization, root velocity, or joint position and velocity channels (Supp Table 7). Rhand adds those, plus a synthetic root at the wrist midpoint and a yaw-only inter-wrist heading, both needed because a two-hand system has no joint at its kinematic center.
As the reviewer pointed out, these channels add no information, since positions and velocities are exactly recoverable from the rotations under MANO forward kinematics; their value is as a generation-side inductive bias, which the numbers above quantify. The only costs are disk footprint and resizing each model's first and last layer, a negligible parameter change. At evaluation we are deliberately stricter: our TMR evaluator scores only the 201-D rotational essential subset (Supp B.6), so quantized and continuous generators are compared on channels where neither is advantaged.
Setup note. To stay faithful to each original implementation, every model keeps its per-model hyperparameters from Supp Sec. E rather than a shared recipe (Kimodo M: 80M, batch 1024, LR 2×10−5; MDM DiP: 40M, batch 512, LR 3.27×10−4; MoMask: 12M per stage, batch 1536, LR 3.46×10−4). Across all tested representations, only each model's input and output dimension changes.
2. Caption fidelity and hand-pose plausibility (user study). [Q2-Gnnu; Q1-Gnnu; Q1-4twm] We conducted a user study that assesses both caption fidelity and pose reconstruction quality. From the validation split we randomly sampled 250 clips, 50 per detail level. For each, raters viewed the 3D reconstruction (full body with the hands highlighted) side-by-side with the source video, together with one caption drawn at random from the five detail levels (L0 to L4). Because the levels differ in length, each caption is labeled with its intended level and judged at that level, so a short caption is not penalized for omitting detail. Raters answered three 5-point Likert questions: (i) overall action match; (ii) caption-motion accuracy and faithfulness, that is, whether the stated hand(s), finger motion, grip, and palm orientation or gesture are correct and nothing is invented; and (iii) quality of the estimated hand reconstruction (jitter, discontinuities, unnatural finger poses). Level assignment was balanced across raters. We note that a 5-point scale gives a coarse signal: it is designed to expose systematic caption or reconstruction errors and to compare quality across the five levels.
Results. Twelve raters produced 370 ratings over the 250 clips, 74 per detail level (some sequences had more than one rater).
Captions describe the captured motion faithfully: question (i) averages 4.16/5, with 81% of ratings at 4 or above and 95% at 3 or above, and question (ii) averages 3.79/5 (66% at ≥4, 87% at ≥3). The per-level breakdown carries the more informative result. Hand-specific accuracy is flat across the hierarchy, staying within 3.70 to 3.96, so the finger-level detail that longer captions add is not being invented, which is the failure mode a VLM captioner is most at risk of. Overall action match declines modestly with length, from 4.51 at tag to 3.92 at paragraph, as expected since a longer caption gives a rater more individual statements to disagree with. Question (iii), the pose reconstruction performance, received a mean score of 3.53/5. It is above the midpoint, so raters found the recovered motion generally plausible, while some visible artifacts remain. We view this as the price of scale: 884 hours of in-the-wild bimanual motion is extremely difficult and costly to reach with high-end mocap, so a quality trade-off against studio capture is expected, and the rating indicates that what we obtain is of above average quality and usable. It also leaves clear headroom for monocular hand-recovery methods competing with WiLoR, and any such improvement propagates directly to the dataset. We discuss this further in point 3.
For the revision we will expand the study on both axes, more raters and more clips, to tighten these estimates.
3. Pose-recovery reliability. [Q1-Gnnu; Q1-4twm] Our recovery is at least as reliable as WiLoR [21], a peer-reviewed, widely adopted, and rigorously evaluated bimanual estimator whose accuracy is established on standard in-the-wild benchmarks. We do not modify its estimation and only add cleanup on top: (a) each frame is reconciled against the temporally consistent SMPL wrist from RoMo's body pipeline, with IK on disagreement, a cross-check the raw monocular estimator lacks (Sec. 3.1); (b) interpolation is limited to gaps of at most 5 frames, with longer gaps split or discarded; and (c) a detection-ratio filter drops clips with low per-hand WiLoR confidence. These steps only stabilize or remove weak frames, so the retained distribution is at least as clean as raw WiLoR, and the GT rows of Table 2 (jerk 14.3, inter-hand penetration 0.64%, self-penetration 0.002 mm) confirm coherent motion rather than regression noise. Since WiLoR's accuracy is already characterized in [21], our aim is to confirm that these additions preserve it on our pool, which is what question (iii) of the user study above demonstrated.
We hope the new ablations, user study, details, and commitments address the reviewer's concerns and support a positive final assessment.