- Rating
- 4
- Clarity
- 3
- Confidence
- 2
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper proposes CORAL, a training-free and architecture-agnostic method to reduce object hallucination in VLMs using a visual data-splitting strategy and a mirror statistic. For each image it creates two symmetrically perturbed views and, per object, compares the model's logits across the original and perturbed views to form a mirror statistic. Objects that respond consistently across the symmetric perturbations are treated as visually grounded and retained, while those that respond inconsistently are treated as hallucinations and eliminated via a false-discovery-rate-control threshold. The method is evaluated on 3 VLMs across 3 datasets and shows consistent improvements over prior work through modest reductions in FDR and larger gains in power.
Strengths and weaknesses
Strengths:
- The proposed idea with framing hallucination suppression as a control with FDR is interesting.
- Making the method training free and architecture agnostic and experiment on various architecture is very good.
- The writing style is clear and the work is well motivated.
- The empirical results indicate the method itself seems to work, in particularly keep power scores high.
Weaknesses:
-
Lemma B.1 requires Corr (U,V) = 0. The proof in line 931 claims this holds by construction and conditioned on Z_V. In Equation 3, both views use same Z_v with sign flip. Doesn't this make delta+ and delta- correlated ? please clarify this.
-
Line 235 says "constructed independently". That's computationally independent but not statistically independent right ? Doesn't the FDR approach require the null statistics to be independent across objects ? In Fig 2, isn't the hallucinated object dog linked to the scene context same as the real objects. Imagine if there were 3 hallucinations like car and bicycle as well as dog. Wouldn't they all be correlated to scene context. Isn't this assumption violated ?
-
Does FDR act as a control? The q sweep experiments in ablation are missing FDR on y axis but the precision stays static after q=0.1. Isnt that a sign that method isnt working as control ?
Minor: line 73 - "two splitted" -> check grammar line 83 - bounds -> bound
Questions
I am assigning my final score primarily due to W1 and W2. I request the authors to address these. This raises fundamental questions about how the method is framed and how it builds on the prior methods. I would be willing to raise my score if W1 and W2 are resolved.
Regarding W3, I believe if the q sweep against FDR should be shown. If the results show the claim is true, no change is needed. If the results show the control doesnt work as intended, I ask the authors to reframe the contribution accordingly.
Limitations
The authors haven't discussed the independence assumptions mentioned W1 and W2.
Paper formatting concerns
NA
Final justification
The authors have addressed the weaknesses raised by me. Therefore, i m upgrading the score.
We thank the reviewer for the positive assessment of our work and for identifying important weaknesses in the paper. We also appreciate the constructive suggestions, which have helped us improve the clarity and rigor of the manuscript. Below, we respond to each concern point by point.
We thank the reviewer for carefully identifying this issue in our use of Lemma B.1 to justify Theorem 3.1. We agree that the original proof was not stated correctly. Since the two mirror views are constructed from the same noise realization with opposite signs, \begin{equation} f_{\mathbf v}^{\pm}=\mathbf v \pm \tau_v Z_v,\end{equation} the resulting quantities Δt+ and Δt− are coupled and are not necessarily uncorrelated. Moreover, conditioning on Zv makes the two perturbations fixed and therefore does not justify the claim that Corr(U,V)=0 holds by construction. We will remove this incorrect argument and will no longer directly invoke Lemma B.1 as the basis for Theorem 3.1.
In the revision, we will instead state the technical condition required for CORAL directly as an approximate conditional sign-flip invariance assumption under the null. Let the null hypothesis be \begin{equation} H_{0t}: \text{no systematic visual evidence supports token } y_t. \end{equation} Specifically, rather than conditioning on Zv, we will condition on the shared context consisting of the image, text input, and decoding history, \begin{equation} \mathcal G_t=\sigma(\mathbf v,\mathbf x,\mathbf y_{<t}). \end{equation} For visually non-grounded tokens, we assume \begin{equation} (\Delta_t^+,\Delta_t^-)\mid H_{0t},\mathcal G_t \overset{d}{\approx} (\Delta_t^+,-\Delta_t^-)\mid H_{0t},\mathcal G_t , \end{equation} where ≈d denotes approximate equality in distribution. Together with the antisymmetry of the mirror functional, \begin{equation} M(a,b)=|a+b|-|a-b|, \qquad M(a,-b)=-M(a,b), \end{equation}
this condition directly implies approximate null symmetry of the mirror statistic, \begin{equation} \Delta_t\mid H_{0t},\mathcal G_t \overset{d}{\approx} -\Delta_t\mid H_{0t},\mathcal G_t, \end{equation}
and hence
\begin{equation} \Pr(\Delta_t \geq s \mid H_{0t}, \mathcal G_t) \approx \Pr\left(\Delta_t \leq -s \mid H_{0t}, \mathcal G_t\right). \end{equation}
This clarification resolves the issue raised in W1: our FDR procedure does not require Δt+ and Δt− to be uncorrelated. Instead, it requires approximate sign symmetry of the mirror statistic under the null, which is the property used to estimate false discoveries from the negative tail. We will revise the theorem statement and proof accordingly, remove the unsupported correlation claim, and clearly distinguish our logit-based mirror construction from the Gaussian mirror regression setting.
Importantly, this correction does not change the proposed CORAL or the empirical procedure. The mirror statistic remains and the FDR thresholding rule continues to rely on approximate null symmetry and positive-tail enrichment for visually grounded tokens. Therefore, the clarification does not affect the algorithm, experimental results, or main contribution of the work; rather, it makes the assumptions and proof consistent with the actual coupled mirror-view construction.
We will also clarify that this condition is not guaranteed by Gaussian perturbation alone. Given this working null condition for the nonlinear LVLM setting and will be examined empirically using visually non-grounded tokens, positive-versus-negative null-tail diagnostics.
Thank you for pointing this out. We agree that the phrase "constructed independently” in Line 235 is potentially misleading. Our intended meaning was that the object-wise statistics are computed separately for each candidate object, not that they are statistically independent. We will revise the wording from "constructed independently” to "constructed separately” to avoid suggesting mutual statistical independence.
Importantly, CORAL does not rely on full independence across all object-level null statistics. The relevant requirement is weaker: under the null, the mirror statistics should have approximately symmetric positive and negative tails, and the empirical tail counts should concentrate around their expectations. This type of condition is standard in mirror-statistic and knockoff-style FDR analyses. For example, Gaussian mirror statistics have been shown to achieve asymptotic FDR control under mild dependence conditions among covariates/statistics, rather than requiring full independence. More generally, the FDR literature has long recognized that exact independence is often unnecessary: Benjamini-Yekutieli (2001) [1] showed FDR control under positive regression dependence, and knockoff/mirror-statistic methods rely on symmetry or exchangeability properties that can tolerate substantial correlation among features/statistics [2].
Concretely, in our setting, for a candidate threshold s, define the null-tail indicators \begin{equation} I_t^{+}(s)=\mathbf 1{\Delta_t\ge s},\qquad I_t^{-}(s)=\mathbf 1{\Delta_t\le-s}.\end{equation} Our analysis requires approximate marginal symmetry, \begin{equation} \mathbb E[I_t^{+}(s)] \approx \mathbb E[I_t^{-}(s)],\end{equation} for null objects, together with a weak-dependence/concentration condition such as \begin{equation} \sum_{t,u\in\mathcal S_0} \left| \operatorname{Cov}{I_t^{\pm}(s),I_u^{\pm}(s)} \right| =o(|\mathcal S_0|^2),\end{equation} uniformly over the candidate thresholds. This condition allows correlations induced by the shared image, scene context, and decoding history, as long as the dependence is not pervasive across a non-vanishing fraction of all null objects. In other words, local or block dependence is permitted, while the condition mainly rules out a degenerate case in which almost all null statistics move together. Therefore, the reviewer’s example is valid in the sense that hallucinated objects such as dog, car, and bicycle may indeed be correlated through the same sense context. However, this does not by itself violate the assumption. Such objects form a small context-dependent cluster within an image, and weak or block dependence of this form is compatible with the type of asymptotic FDR control used by mirror-statistic methods. The control argument does not require the hallucinated dog statistic to be independent of the hallucinated car or bicycle statistic; it requires that, aggregated over many images/objects, the negative-tail mirror counts provide a calibrated estimate of the positive-tail null discoveries.
We will revise the manuscript accordingly:
[1] Benjamini, Y., & Yekutieli, D. (2001). The Control of the False Discovery Rate in Multiple Testing under Dependency. The Annals of Statistics, 29(4), 1165–1188.
[2] Xing, X., Zhao, Z., & Liu, J. S. (2023). Controlling false discovery rate using Gaussian mirrors. Journal of the American Statistical Association, 118(541), 222-241.
Thank you for raising this question. We would like to clarify that the FDR controlled by CORAL and the precision reported in the ablation figure (Fig. 4) are defined at different evaluation levels, and therefore they should not be interpreted as direct complements of each other.
In CORAL, the FDR is computed and controlled at the per-image decision level, i.e., it measures the expected proportion of falsely accepted/generated responses among the selected responses for each image under the target level q. In contrast, the precision, recall, accuracy, and F1 scores in the ablation figure follow the standard POPE evaluation protocol adopted by prior work. These metrics are computed over the benchmark’s binary QA predictions and are intended to measure downstream hallucination-detection performance. Because these two quantities are defined over different units and aggregation procedures, a stable POPE precision curve after q=0.1 does not imply that the FDR-control mechanism is ineffective.
More specifically, increasing q relaxes the FDR constraint and allows CORAL to retain more candidate responses. This typically improves recall, as observed in the figure, but it does not necessarily lead to a monotonic or proportional change in POPE precision. Once the retained responses are already dominated by high-confidence correct predictions, further relaxing q may mainly affect recall or coverage while leaving benchmark-level precision relatively stable. Therefore, the saturation of precision after q=0.1 is not a sign that CORAL fails to act as a control; rather, it indicates that under the POPE metric, additional retained predictions do not substantially change the ratio of correct positive predictions.
To directly verify the control behavior, we report the target FDR level q together with the empirically achieved FDR in Supplement Fig. 10. As shown there, the empirical FDR closely follows and remains controlled with respect to the specified target q, demonstrating that CORAL indeed functions as an FDR-control procedure. We will revise the manuscript to make this distinction explicit and to avoid confusion between the per-image FDR controlled by CORAL and the benchmark-level precision/recall metrics used for comparison with prior methods.