- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The authors observe that current generative emulators of protein dynamics, i.e., emulators that mimic molecular dynamics (MD) output without having to run such expensive simulations, are limited in their ability to generate trajectories that adequately explore the distinct regions of a protein's conformational space. To address this difficulty, the paper introduces a history-dependent bias that steers a pretrained/frozen emulator away from states that have been previously visited. To ensure that the resulting trajectories/frames still represent realistic protein structures over long time horizons, drift is corrected during inference via a refinement projection. The method is tested on benchmark datasets, assessing metrics such as structural validity, diversity, and coverage of conformational states.
Strengths and weaknesses
The paper tackles a pertinent scientific problem and is generally clear. While generative frameworks such as BioEMU and AlphaFlow have recently gained substantive attention as a way to generate conformational ensembles without expensive MD simulations, they do not yield time-step MD-style trajectories and their generated ensembles still may not have adequate coverage of low-energy conformational states. Both of these potential weaknesses might be partially mitigated by the proposed ideas. While the development of biased sampling methods to access difficult-to-reach states is well-known, its particular application and implementation here appears to be well-executed and original. The refinement step provides a simple and sensible correction for the structural drift that might result from the injected bias. The use of pretrained MD emulators allows the proposed bias/refinement to be flexibly incorporated: this is nicely demonstrated on both the authors' custom emulator and the existing ConfRover method. That said, the evaluation presented is rather limited. In Table 1, we find that the implicit bias can somewhat improves diversity (e.g., relative to BioEmu) with the trade-off of having more structures with atomic clashes, at least at short time-scales. Subsequently, the long time-scale experiment applies the bias+refinement to a set of 12 proteins under various bias strengths and time horizons; however, baseline methods were not included in this arguably more interesting set of examples. At a minimum, it would have been helpful to see the coverage of MDGEN, BioEmu, AlphaFlow ensembles on these examples, to provide context to these results. For example, currently we cannot see how difficult it is to access these low-energy states using baseline generative methods, and what improvement the proposed method brings. Overall, the work has the potential to be significant in enhancing the study of protein dynamics, but as presented the empirical results are not quite convincing.
Questions
- Low-energy state coverage is omitted in Table 1; was there a specific reason? Was it due to the short time-scales used and therefore coverage would not be meaningful?
- In contrast, to complement Figure 2 in the long-timescale case, can the conformational coverages of baselines also be included and discussed? This would seem to be quite important for demonstrating the advantages of the proposed method, e.g., to support the claim that MDGen might concentrate in visited basins.
- I was also left wondering about the quality of the generated trajectories, especially after refinement post-processing. Are the frame-to-frame structural changes realistic, i.e., generally without abrupt shifts/artifacts that are biologically unreasonable at the frame timescale? In particular, does this aspect of the trajectories compare reasonably to the default output of the emulator?
- The authors' custom emulator appears to have surprisingly strong performance compared to ConfRover, given its relative simplicity (e.g., at least in the Table 1 metrics). Can some explanation of this be provided?
If these questions could be plausibly addressed, I would be open to raising my score.
Limitations
Limitations are adequately described.
Paper formatting concerns
None
Final justification
The authors have adequately resolved my main questions and concerns. I have increased my score to 4, in light of the paper's contributions and recognized limitations.
Table 1. Effect of MD Reference Length on Low-Energy-State
Table 2. Comparison of Conformational Coverage on the Fast-Folding
Table 3. Analysis of Frame-to-Frame Structural Changes on the Fast-Folding Benchmark