Abstract

Precise localization of recording electrodes is fundamental to systems neuroscience; yet, current methods depend on labor-intensive post-hoc histology, which is incompatible with real-time feedback or chronic implants. We test the hypothesis that the electrical signals being recorded themselves carry sufficient anatomical information to localize their recording site in 3D atlas coordinates, without the need for histology. To probe this, we introduce a self-supervised framework that learns geometry-aware representations of single-channel local field potentials (LFP), leveraging probe channel geometry as a self-supervisory signal. We compare speech-based SSL objectives (e.g., masked prediction) against geometry-aware objectives that constrain the embedding space to mirror physical channel layout along the probe. These representations outperform masked-prediction baselines, and the gains compound at larger data scales. We test downstream analysis with 3D coordinate regression and brain region classification, benchmarking three SSL backbones (Wav2Vec 2.0, Whisper, and Data2Vec) against supervised baselines (AnyNet, ViT, and classical spectral classifiers) across datasets, laboratories, species, and probe technologies. Our method achieves state-of-the-art results in brain region classification and 3D coordinate regression from raw single-channel LFP, outperforming all baselines, affirming our hypothesis.

Keywords:
Sydney, Main Track

Reviews

Among:
Shape:
123456this paper, Bottom 49%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 4.33 over 3 reviews, above 49% of the others.
Reviewer_exC2OpenReview ↗
Rating
5
Clarity
3
Confidence
4
Originality
3
Quality
4
Significance
3
Read review
Summary

The paper focuses on predicting new subjects probe channel location from raw LFP. The method builds on the recent literature framework, specifically lfp2vec, using a pretained audio backbone and SSL technique on large scale neuropixel datasets and provides two major novelties: (1) the method matches the LFP channel activity to the channel 3D brain position (CCF coordinates) and includes uncertainty quantification and refinement at inference time. This generalizes the previous approaches that were specialized at classifying brain regions at a specific brain atlas level when CCF coordinates can be mapped to any level. (2) It introduces 2 new SSL contrastive objectives based on the channels' CCF coordinates or the probe's known geometry. The paper studies its method on 2 large scale electrophysiology datasets (Allen Brain Observatory and IBL Brain Wide Map) and across multiple settings: 5 different pretaining scales, 3 audio backbone types (wav2vec 2.0, Whisper, and Data2vec), 3 SSL objectives (1 mask-based and 2 geometry-based), 3 localization head training regimes, and 2 generalization types (species and probe geometries).

Strengths and weaknesses

The paper benefits from several strengths. (1) It provides a very compelling set of results thanks to its study across multiple settings (pretaining scales, audio backbone types, SSL objectives, localization head training regimes, and generalization types). Additionally, it provides an extensive ablation study as well as a comparison with supervised and spectral features baselines. This contributes to the quality of the paper and it's significant as it provides general helpful insights to the community on encoding LFP data with pretrained audio backbone and SSL objectives. (2) It compiles high quality figures and systematic qualitative results (best/worst probe location prediction) that help to understand the method or interpret the results impacting the clarity of the paper. (3) The localization downstream task is novel in the literature as the SSL models focused on brain region prediction. This novelty is the most significant one as it opens precise probe localization without anatomical annotation with numerous applications in neuroscience. (4) The SSL objective introduced good inductive bias for the downstream, especially ChanDistc that does not need any anatomical annotation. (5) The localization head is designed and with uncertainty qunatification (Gaussian Head) and test time refinement with probe geometry inductive bias (i.e., Kabsch refinement and confidence weighting) (6) Documented code is provided as well as detailed hyperparameters giving the good materials and guarantees on the reproducibility.


The paper still needs to address some weaknesses (1) It provides evidence that raw LFP can provide precise channel location but never studies the FLP temporal resolution needed to obtain this location (always used a 3-second window). (2) The downstream localization head would benefit from some extra experiments to fully understand the implications of its architecture and its loss design on the final results. (3) It requires some clarification on certain key points.

Questions

Major questions that would strengthen the submission (ordered by importance):

Q1 Temporal Resolution Study:

The paper's key question is to prove that raw LFP signal is sufficient data to predict CCF coordinates. Only 3-second windows are used when it seems that the method is not coupled to this time scale, as the coordinates are predicted from pooled latents across the temporal dimension.

  • Could you please motivate the choice of the 3-second window?
  • Could provide other window size results (e.g., 1 second, 2 seconds, 5 seconds, 10 seconds), at least one dataset at one data scale (e.g., Allen Brain Observatory at 75K or lower if the compute capacity is limited)? Providing these results would help the central question, as it could add to the answer of how much temporal resolution of the LFP signal is necessary to be able to predict the precise channel location.

Q2 Downstream Localization Head:

  • While well motivated (i.e., gaining uncertainty quantification with an impact on downstream applications) the heteroscedastic Gaussian head requires a slightly different loss and more variables to predict than the MSE regression loss on 3D coordinates. Could you please ablate this with one result using MSE regression loss on 3D coordinates to see if the performances are similar?
  • The head is a MLP mapping in a nonlinear way the latent of the encoder to the 3D coordinates. Could you provide an experiment where the MLP is replaced by a linear layer across the 3 head training regimes for 1 dataset and 1 data scale?

This would help understand if and to what extent the embeddings are linearly spatially organized.

Q3 Major clarification requirement:

  • At lines 145-146, the paper mentioned "To obtain a discrete brain region label, we simply look up the predicted coordinate in the Allen CCF annotation volume." whereas in lines 511-513 it mentions "For classification experiments (e.g., depth-5 balanced accuracy), the regression head is replaced with a linear projector (768 →256) followed by a classifier (256 →C, where Cis the number of classes at the target depth level)." Could you clarify this difference?
  • The Allen CCF is a mouse coordinate system, how can the method achieve zero-shot transfer between macaque and mouse atlases? Is the same localization head used? Could you please provide more detail about this zero-shot cross speacies coordinate transfer?
  • The two SSL objectives introduced are similar as the 3D CCF coordinates are constrained on the probe 2D space and could make CCFDistc and ChanDistc equivalent. My understanding is that ChanDistc would be limited to a single probe when CCFDistc can be multi-probe, could you confirm this is the difference between both objectives? If not, could you provide more details to help differentiate and highlight their differences?

Q4 Real Time and Inference:

Some potential applications would be to use the method in real time to localize the probe in the subject's brain. Could you please provide a runtime inference detail of the different components of your method (between preprocessing, audio backbone forward pass, and test time refinement)?

This would identify the pipeline's runtime bottleneck and provide guidance for future research direction to be localize the probe in real time.

Minor questions or comments:

  • The section 2 Datasets does not mention the NeuroNexus dataset.
  • The 2 datasets used for the transfer results, i.e., NeuroNexus and Macaque, lack details. What are their references? Are they publicly available or not.
  • The spectral feature baselines (kNN/band, kNN/PCA-PSD, Ridge/PSD) do not have references. Are they used in other works?
  • The paper would benefit from better referencing of the appendix in the main text (e.g., the appendix D.3 could be referenced to guide the readers that want more details about Kabsch Refinement).
  • Hyperparameters are tuned using Optuna (mentioned in the appendix E) but could you be clear about what hyperparameters?
  • For clarifying unfamiliar readers to audio encoders, it could be beneficial to clarify that these models are single-channel models.
  • The related works could benefit from the additional works than NEMO on the SSL methods for spike brain region classification (e.g., NeuPrint [1], NuCLR [2], ...).
  • Some figures would benefit from higher resolution (e.g., Figure 3).

[1] Mi, Lu, et al. "Learning time-invariant representations for individual neurons from population dynamics." Advances in Neural Information Processing Systems 36 (2023): 46007-46026.

[2] Arora, Vinam, et al. "Know Thyself by Knowing Others: Learning Neuron Identity from Population Context." Advances in Neural Information Processing Systems 38 (2026): 99472-99501.

Limitations

yes

Paper formatting concerns

No

Final justification

This paper targets an open gap: localizing a probe in a subject from raw LFP. The potential impact on computational neuroscience is high, since the method could, for example, replace histology or serve as an independent quality-control check on it, and the authors addressed all of my concerns with careful follow-up during the rebuttal. They also added results that push the work in a more realistic direction: inference analysis, context length, and insertion trajectory data (following Reviewer uaNP's suggestion).

I maintain my score of 5. In my view, the paper has high potential value for the computational neuroscience community and is supported by strong evaluation.

Reviewer_erKHOpenReview ↗
Rating
3
Clarity
2
Confidence
3
Originality
3
Quality
3
Significance
2
Read review
Summary

The paper investigates whether single-channel LFP recordings can predict electrode location in 3D atlas coordinates without histology at inference time. The authors adapt pretrained audio foundation models (Wav2Vec2, Whisper, Data2Vec) as LFP encoders, introduce geometry-aware contrastive objectives, and evaluate across multiple datasets and species, including macaque data.

Strengths and weaknesses

Quality (updated after rebuttal). (1) Test-time information use — resolved. My original central concern was that the Kabsch refinement might use ground-truth coordinates at test time. The authors clarified that it uses only probe-geometry metadata available at inference (column spacing, per-channel depth spacing) to fit a rigid transform, with no GT; the GT-based Oracle is separated as a diagnostic lower bound. This is legitimate post-processing. (2) Evaluation rigor — resolved. Subject-level splits with verified empty subject/session/probe overlap (Tables 3–4) rule out the leakage/over-easy-split concern. (3) Consistency & statistics — resolved. The authors corrected the Macaque result (HistGBM best), re-ran Data2Vec with matched hyperparameters (yielding the claimed monotonic trend, Table 5), and added 5,000-sample bootstrap significance tests versus lfp2vec (significant at 75k/301k/1M, not at 25k). (4) Remaining weakness. On standard per-channel metrics (mean/median error, R², correlation), supervised baselines remain competitive or superior; the method's advantage is specific to the Kabsch geometric-consistency metric. Absolute localization at fine depth resolution (~1–1.5 mm RMSE at 309 classes) remains proof-of-concept.

Clarity. The refined rebuttal materially improved clarity (explicit Kabsch setup, input/output maps, corrected tables). The camera-ready should fold these in, particularly the corrected Macaque and Data2Vec results.

Significance. Self-supervised, geometry-aware channel localization that generalizes across animals and datasets is a useful contribution to the community, especially as a foundation for probe-insertion trajectory estimation. Significance is real but bounded by the current absolute accuracy and by the fact that the headline advantage is metric-specific.

Originality. Incorporating a Kabsch rigid-alignment step as a differentiable/known-geometry prior into a representation-learning pipeline for neural probes is a novel and sensible domain-specific inductive bias; it distinguishes the work from generic regression baselines and from prior lfp2vec-style approaches. The originality is moderate-to-good, now that the mechanism is shown to operate without ground-truth leakage.

Questions

Please report standard per-channel metrics and Kabsch-consistency metrics side by side, and state plainly where supervised baselines win, so readers can judge the trade-off. Please include the limitations section (fine-depth RMSE, single-metric advantage) as committed.

Limitations

Now adequately acknowledged in the rebuttal: the authors concede the fine-depth proof-of-concept status and the metric-specific advantage, and commit to a dedicated limitations section and de-emphasizing the 202 µm best-case result. Please ensure these appear in the final version.

Paper formatting concerns

NO

Final justification

The geometry-aware representation-learning idea is interesting, but the current version overclaims and may not be valuable as they claimed.

Reviewer_uaNPOpenReview ↗
Rating
5
Clarity
3
Confidence
3
Originality
3
Quality
3
Significance
3
Read review
Summary

The paper tackles the problem of inferring an electrode's anatomical location in the brain directly from recorded LFP signals. The authors train three backbones under different objectives: masked modeling, a contrastive loss using histology-derived 3D coordinates, and a contrastive loss based on inter-channel distance along the probe. They report that the geometry-aware objectives outperform masked modeling, that the channel-distance objective improves performance without requiring histology, and that the model can perform continuous 3D coordinate regression rather than only discrete area-label classification. They also compare their best model against baseline backbones across data scales. This addresses an important and timely problem. With the rapid growth of large-scale electrophysiology and its extension toward human and clinical settings, the ability to infer an electrode's 3D coordinate from the recorded signal alone, ideally referenced to an atlas available across model organisms, would be highly valuable.

Strengths and weaknesses

Strengths

  1. The problem is well chosen and well motivated. Inferring electrode coordinates from neural signal, rather than relying on post hoc histology, is a real bottleneck for large-scale and longitudinal recording, and the focus on atlas-referenced, cross-species localization is timely.

  2. The two key contributions, a geometry-aware loss and continuous 3D coordinate regression, are novel. Prior work has inferred discrete area labels but has not, to my knowledge, performed continuous 3D coordinate regression, nor placed probe geometry into the self-supervised objective itself. Notably, the closest prior method (lfp2vec) explicitly trains without probe geometry and notes incorporating spatial priors into the loss as future work.

  3. The empirical scope is reasonable: multiple species, multiple backbones, and data-scaling analyses, with a number of controls.

Weaknesses

My central concern is whether the advance is sufficient for acceptance, and this is tightly coupled to an unresolved question about what the baselines actually are.

  1. The two novelties are appealing, but the paper does not establish that they constitute a clear step forward relative to the field. In particular, it is not immediately apparent whether the self-supervised baseline corresponds to the closest prior method, lfp2vec, which uses a wav2vec-2.0-style architecture trained with a temporal masked-prediction contrastive objective — a contrastive loss whose positives and negatives are defined by time step, combined with masked prediction. The authors must clarify whether their compared SSL model is lfp2vec, including the temporal contrastive loss. If the paper's "masked" baseline is masked-only, then it is a strictly weaker baseline than the relevant prior method. Sharing the wav2vec-style backbone is not sufficient on its own: the comparison is meaningful only if the baseline also matches lfp2vec's objective (masked + temporal-contrastive + diversity) and its training regime (audio initialization followed by in-domain pretraining), since the latter is the dominant factor in lfp2vec's own ablations. Please state explicitly which of these the SSL baseline uses, and ideally compare against lfp2vec as published. This is feasible given the dataset overlap.

  2. The paper shows that channel-based geometry helps self-supervised learning, but not that the channel-distance method approaches the histology-coordinate method. The latter will have considerable more impact, because most data does not come with histology. The role of the ground-truth coordinate model is also ambiguous: is it intended as an oracle/upper bound, or simply as another condition? It would be valuable to show a single data-scaling curve plotting both the channel-distance proxy and the coordinate-supervised model on the same metric and axis.

  3. Since the thesis rests on geometry-aware objectives outperforming masked modeling and prior methods, each improvement should be reported as an effect size with variance across seeds, ideally in a table.

  4. The paper contains many figures and controls, but it is difficult to identify the key result and the figures that support it. The results text would benefit from explicitly stating the main finding, what the ceiling is (ground-truth coordinates vs. a coordinate-trained model), and how the method compares to prior work. Several figures also need work for readability — for example, the labels and colors in Fig. 3a are essentially unreadable.

Questions
  1. In Fig. 5 and the other backbone comparisons, is the self-supervised model lfp2vec including its temporal masked-prediction contrastive loss, or is it masked modeling only?

  2. What role does the ground-truth coordinate model play; is it an oracle/upper bound, or another experimental condition? Please state this explicitly.

  3. Can you provide a single scaling analysis, on a shared metric and axis, showing the channel-distance method approaching the coordinate-supervised method as data increases?

  4. Did you consider conditioning or initializing the coordinate readout on experimentally available metadata beyond on-probe channel geometry, e.g., insertion coordinates in skull space, insertion angle, or depth? From the perspective of an experimental neuroscientist, a model that combines neural signal with such priors to predict an atlas-referenced 3D coordinate is the version of this method that would be most directly adoptable, and it follows naturally from the geometry-aware framing.

Limitations

See above

Paper formatting concerns

None

Final justification

I increased my score from 3 to 4, based on the replies of the authors during the rebuttal period. After addressing my last concern, I am raising my score to 5.

Comments on the paper

1 comment
Meta-review

Initial meta-review: Currently your paper needs additional clarification and evaluation.

The authors noted the significance and timeliness of the problem and proposed method, and some reviewers noted the novelty of the approach. However there were multiple concerns about the evaluation that need to be clarified during the discussion period (please see the reviews for specific details) and additional experiments run if the original indeed suffer from the issues identified by the reviewers to both satisfy concerns regarding quality of the results and reproducibility:

  • The SSL baseline and the objective used in training it (i.e. comparison to LFP2vec is required if this is not the baseline in the paper),
  • the train-test split and whether there is leakage of of same session / animal across train and test,
  • the role of the ground-truth coordinate model / Kabsch alignment,
  • clarification regarding zero-shot cross species coordinate transfer,
  • ablation and robustness to hyperparam choices.

Reviewers also noted multiple issues with clarity of the writing, specifically contradictions between the text, the figures and the captions, and descriptions of the properties of the data. Please clarify during the discussion period how you would modify the text (i.e. which description in the paper is the correct one).

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.