- Rating
- 3
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 2
- Significance
- 2
Read review
Summary
This paper presents ACMA, an unsupervised two-stage method for saccade detection in noisy oculographic signals. The method first applies short-time delay embedding to the gaze signal, then uses PCA and k-means within overlapping windows to identify candidate transitions. These candidates are further validated by fitting a physiologically constrained saccade waveform and applying an R² threshold. The final output includes SAC/FIX/BLINK labels and event-level kinematic parameters. Experiments on two real expert-annotated datasets and one simulated dataset with multiple levels of added pink noise compare ACMA against nine baselines. The results show that ACMA achieves the best overall F1, Cohen’s kappa, and high-noise performance, with particularly improved robustness for saccade detection.
Strengths and weaknesses
Strengths
- The problem is practical and clearly defined. Saccade detection under noisy conditions is important for wearable EOG, clinical applications, and mobile eye-movement analysis.
- The method is intuitive and interpretable. Delay embedding adds short-term dynamic information, while parametric waveform fitting provides physically interpretable outputs such as amplitude, duration, and peak velocity.
- Its unsupervised and modality-agnostic nature is a strength, making it easier to transfer to new devices or noise conditions than supervised deep models.
- The experimental comparison is fairly comprehensive, with nine baselines spanning classical thresholding, adaptive/event-based methods, clustering approaches, and deep learning.
Weaknesses
- The algorithmic novelty is mostly an engineering combination. Delay embedding, k-means transition detection, PCA voting, and saccade waveform fitting all have precedents; the main contribution lies in their integration and evaluation.
- The paper lacks module-level ablations. It does not sufficiently quantify the individual contributions of delay augmentation, PCA projection, explained-variance voting, parametric fitting, and the R² threshold.
- The noise model is somewhat idealized. A pink-noise RMS sweep does not cover non-additive artifacts, drift, occlusion, calibration error, and device-specific dropout common in real wearable or clinical scenarios.
- External real-world validation remains limited. Two expert-annotated datasets plus one simulator are not enough to cover infants, clinical populations, and consumer-grade EOG.
- The kinematic parameters are not yet validated. Although the paper claims to return amplitude, duration, and peak velocity, these metrics are not systematically compared against expert annotations or simulator ground truth.
- PSOs are not modeled, which may affect offset estimation and event labeling.
Questions
- How much does delay embedding itself contribute? If Nd=0 is used while retaining PCA voting and parametric fitting, how much does performance drop?
- How much does parametric waveform fitting contribute? If only the candidate mask from delay-augmented clustering is used, what are the resulting F1, kappa, and timing errors?
- Are the R² threshold of 0.6, window length of 200 ms, hop size of 20 ms, and Nd=3 optimal across all sampling rates and datasets? Was any sensitivity analysis performed?
- On real wearable EOG data or clinical patient data, do the conclusions from the pink-noise benchmark still hold?
- How does ACMA classify microsaccades, smooth pursuit, glissades, and post-saccadic oscillations?
- Is the event-matching IoU threshold of 0.25 too lenient? Under stricter thresholds, does the timing advantage still hold?
Limitations
- The current method outputs only three classes: SAC, FIX, and BLINK. It cannot explicitly identify PSOs, smooth pursuit, or other eye-movement events.
- The benchmark is mainly based on artificially added noise, which cannot fully represent the complex artifacts found in real mobile-device and clinical recordings.
- Hyperparameters still need to be set manually, and cross-device deployment may require retuning.
- The accuracy of the kinematic parameters lacks independent validation.
- Its ability to detect very short, low-amplitude saccades or microsaccades remains unclear.
- The number of real datasets is small, and inter-rater variability among expert annotations is not sufficiently discussed.
Paper formatting concerns
None
Final justification
My suggestion is Borderline reject.
Meta-review
ACMA is an unsupervised two-stage saccade detector: delay embedding plus PCA/k-means to find candidate transitions, then parametric waveform fitting to reject false positives and recover kinematics. Scores are split (borderline reject, borderline accept, reject), but the reviewers agree the problem is well motivated and the method interpretable, while novelty, ablations, and the realism of the evaluation are the weak points.
The rebuttal should take into account the following points
The three reviewers believe that the module-level ablations are missing (gKuk, TUdm, VJXP). Since the contribution is mainly the integration of established components, please isolate the contribution of delay embedding (e.g. Nd=0), PCA voting, and the parametric-fitting/R^2 stage, reporting F1, kappa, and timing errors. Answer gKuk's question of what delay embedding adds over plain PCA/clustering directly.
Testing beyond idealized additive noise would be helpful (VJXP, TUdm). The pink-noise sweep omits structured artifacts (head motion, drift, correlated axes, dropout). Please show conclusions hold on more realistic data, ideally a small annotated wearable/clinical subset.
Characterize native noise and simulator fairness (VJXP). Quantify the native noise of the real recordings and clarify added-only vs total RMS, and address that the simulator shares ACMA's parametric model.
Convincing responses to items 1 and 2 would be an important consideration as we discuss the paper.