- Rating
- 3
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
This work addresses the challenge of dense stereo disparity estimation in endoscopic scenes, where correspondence reliability varies spatially due to weak texture, specular reflection, occlusion, smoke, and instrument contact. The paper proposes Manifold-Stereo, a stereo-monocular refinement framework for endoscopic disparity estimation. It corrects a monocular disparity candidate in a cost-volume-conditioned latent correction space and uses a geometric consistency gate to regulate the contribution of stereo and monocular candidates during recurrent refinement. Experiments are conducted on SCARED, with zero-shot evaluation on SERV-CT and Hamlyn, showing promising performance.
Strengths and weaknesses
The paper studies an important and practically relevant problem. Endoscopic stereo disparity estimation is challenging because reliable and unreliable matching regions coexist within the same frame. The paper correctly identifies that stereo matching may be reliable in textured regions but unreliable around weak texture, specular highlights, occlusions, smoke, and instrument-contact regions. This problem setting is meaningful for endoscopic 3D perception.
However, I have several concerns about the paper.
-
The paper emphasize Manifold-Guided and Manifold-Stereo. However, the paper explicitly states that the geometric terminology used in this work is only “local and operational” and does not refer to a global anatomical manifold. Why do the paper still emphasize the notion of manifold?
-
The claimed manifold in this paper is a local correction space induced by the cost-volume latent state and the residual decoder. What advantage does it have over other related techniques? The authors need to further explain the necessity of introducing the manifold perspective. Moreover, the paper does not provide sufficient theoretical analysis to justify the necessity of this choice.
-
The paper defines stereo reliability as an exponential function of the left-right feature residual, but this design may not be reliable. First, the authors do not explain why the relationship between feature residual and stereo reliability should follow an exponential decay. Second, even if stereo reliability is low, it does not naturally imply that the monocular candidate is more reliable, since both stereo and monocular predictions may fail in complex regions. Therefore, directly using the complement of stereo confidence as the monocular weight is a strong assumption that lacks sufficient support.
-
The current experiments mainly verify its effectiveness indirectly by ablation study. The authors do not further present the weight maps generated by the gate, nor do they analyze whether these weights are truly concentrated in specular, weak-texture, occluded, or unreliable matching regions. Therefore, the existing experiments only show that the gate improves the final metrics, but do not prove that it works in the way claimed by the paper. The authors should provide visualizations of the gate weight maps.
-
The stereo branch adopts a CNN, while the monocular branch adopts a ViT. However, the authors do not explain the reason for this design. Why is CNN more suitable for stereo matching, while ViT is more suitable for monocular candidate generation? In addition, the authors do not provide corresponding backbone ablation experiments.
-
The paper motivates the method by emphasizing that specular reflection, weak texture, smoke, occlusion, instrument contact, and tissue deformation in endoscopic images can lead to local stereo matching failures. However, the experimental section does not provide clear visual examples of these specific degraded cases, nor does it show how these degradations cause existing methods to produce incorrect disparities.
Questions
-
Why does the paper emphasize the manifold concept if the proposed geometry is only local and operational rather than a global anatomical manifold?
-
What indispensable advantage does the proposed local correction space have over standard cost-volume-conditioned residual correction or other refinement techniques?
-
Why should the relationship between left-right feature residual and stereo reliability follow an exponential decay form?
-
Why can the complement of stereo confidence be directly used as the monocular candidate weight, given that stereo and monocular predictions may fail simultaneously?
-
Can the authors provide gate weight-map visualizations to verify whether the gate actually focuses on specular, weak-texture, occluded, or unreliable matching regions?
-
Why does the stereo branch use CNN while the monocular branch uses ViT? Can the authors provide backbone ablations to justify this design?
Limitations
The paper does not sufficiently discuss the limited theoretical support for the manifold terminology, the heuristic nature of the geometric consistency gate, the possible failure of monocular candidates in the same regions where stereo is unreliable, or the lack of direct visualization for the specific degraded endoscopic scenarios used to motivate the method. The paper also does not report enough analysis of computational cost, backbone dependence, or simple confidence-fusion alternatives. These limitations should be discussed more explicitly.
Paper formatting concerns
No.
Final justification
Thank you for the detailed response to my review. The rebuttal further clarifies the meaning of the manifold and provides one-step update and path-regularization ablations to demonstrate the effectiveness of multi-step latent refinement. However, my core concerns still remain. First, the authors mainly show that multi-step residual correction and trajectory constraints improve performance, but this still does not sufficiently explain why the mechanism should be formulated as manifold-guided correction, or what fundamental advantage the manifold formulation provides over conventional residual refinement. Therefore, my main concern regarding the conceptual novelty of the method remains. Second, the rebuttal does not fully resolve the core assumption behind the complementary gate. My original concern about whether low stereo reliability alone is sufficient to justify a higher monocular contribution remains insufficiently addressed. Overall, the rebuttal improves the clarity of the method and strengthens the empirical evidence, but the above core concerns remain. Therefore, I maintain my original rating.
We are grateful to the reviewer jFq8 for recognizing the importance and practical relevance of endoscopic stereo disparity estimation. We address the reviewer's concerns point by point below.
C1/Q1. Meaning of the manifold formulation
We use manifold for the decoder-induced local correction geometry, not a global anatomical manifold. For each stereo pair, the cost volume induces an image-aligned latent neighborhood around Z0; the shared vector field traces a trajectory within it, and the decoder maps its endpoint to a disparity residual. This differs from predicting an unconstrained residual directly in pixel-disparity space: both the endpoint and intermediate path are restricted relative to pair-specific stereo geometry. Formally, the decoder Jacobian induces a local metric, and Supplementary Relation to Local Energy Regularization shows that, under locally bounded decoder sensitivity, the discrete latent path penalty bounds the corresponding correction energy up to local constants. The term therefore emphasizes the structured local correction space and its constrained trajectory.
C2/Q2. Advantage over a standard residual correction
The proposed update differs from a one-step residual head through its parameter-shared path and explicit trajectory regularization. The controlled results are:
The one-step variant uses the same latent encoder, conditioning field, vector field, and decoder, isolating the parameter-shared multi-step path. Its 0.50 px higher EPE shows the benefit over a single residual update, while the no-path-energy result supports trajectory regularization. This analysis is reported in the Ablation Study.
C3/Q3. Why exponential decay for stereo reliability?
The exponential mapping converts the non-negative, channel-normalized squared feature residual r into a bounded stereo-consistency weight, gstereo=exp(−r/τ). Exact left-right feature alignment gives r=0 and gstereo=1; increasing mismatch smoothly decreases the stereo contribution. We use this mapping because it is bounded in (0,1], monotonic, differentiable, requires no hard threshold, and uses a single temperature τ to control sensitivity. It is an RBF-style deterministic similarity score, not an assumption that stereo correctness follows an exponential probability distribution.
C3/Q4. Why use the complementary stereo gate for monocular contribution?
1−gstereo is a contribution-allocation coefficient inside the learned recurrent updater, not an estimate of monocular correctness. When left-right alignment is reliable, high gstereo preserves metric stereo evidence. When stereo support decreases in specular, weak-texture, occluded, or mismatched regions, the complementary weight reduces repeated reliance on the same uncertain stereo residual and increases the contribution of the corrected monocular candidate. This candidate is not an independent final prediction: it has already been conditioned by the stereo cost-volume latent state and aligned to the current stereo scale, while the updater continues to receive stereo correlation and state features. As shown in Supplementary Reliability-Weighted Contribution, this weighted contribution is also the minimizer of a local quadratic surrogate between the stereo representation and the corrected monocular representation. Replacing this spatial allocation with uniform mixing increases EPE from 3.05 to 3.30. Both candidates can still fail in the same region; the complementary gate controls contribution but does not guarantee that either candidate is correct.
C4/Q5. Gate weight maps
The paper assigns different contributions, rather than claiming that both branches attend to the same difficult regions. High wstereo=gstereo occurs where textured structures and left-right alignment provide reliable metric correspondence. High wmono=1−gstereo occurs where stereo support is weak, including specular highlights, weak-texture tissue, occlusion or depth boundaries, and photometric mismatch; it increases the contribution of the corrected monocular context in these regions. A high wmono therefore indicates low stereo support, not guaranteed monocular correctness.
As rebuttal policy prohibits additional figures, we summarize the gate-map diagnostic. Across the 10 SCARED test keyframes, the top 20% monocular-gated pixels average approximately wstereo:wmono=0.14:0.86. They form localized clusters around highlights, occlusion/depth boundaries, and photometric mismatch rather than a uniform mixture. This observation, together with the uniform-mixing EPE increase from 3.05 to 3.30, supports spatially varying candidate allocation.
C5/Q6. Why a CNN stereo branch and a ViT monocular branch?
The two branches provide complementary information. The stereo branch constructs pair-specific metric correspondence, while the monocular branch supplies the fixed Depth Anything V2 prior and larger-context features. Its ViT architecture is inherited from Depth Anything V2 rather than selected as a claim that ViTs are intrinsically superior for monocular estimation.
With the monocular branch and remaining modules fixed, we replace only the stereo backbone:
The narrow MAE (2.53--2.58) and EPE (3.05--3.22) ranges show that the method does not depend on a specific stereo backbone. MobileNetV2 gives the lowest EPE and ties for the lowest MAE, supporting its use as the default.
C6. Visual Evidence For Degraded Regions
Because the rebuttal interface accepts text only, we provide the degraded-region analysis directly. We inspect aligned regions covering specular highlights, weak-texture tissue, smoke, occlusion or depth boundaries, instrument contact, tissue deformation, and photometric mismatch.
For each ROI, we compare the initial stereo hypothesis, corrected monocular candidate, final prediction, absolute error, degraded-region proxy, and gate response under a shared scale. Specular or saturated regions violate local photometric and feature consistency; weak-texture tissue makes the cost volume ambiguous; smoke introduces low-contrast partial occlusion; and occlusion boundaries, instrument contact, or tissue deformation create unmatched pixels and rapid local disparity changes. These factors lead to local errors in the initial stereo estimate that are difficult to distinguish in full-frame visualizations.
Across these regions, the initial stereo errors increase where left-right support becomes unreliable. Stereo evidence remains more active in visually and geometrically better-matched areas, while the corrected monocular candidate receives a larger contribution in ambiguous local regions. This is consistent with the gate-map diagnostic above and explains why the numerical improvements can be difficult to distinguish in full-frame disparity renderings.
Limitations
We agree that these concepts need clearer scope. The manuscript explains their endoscopic use and operational roles, but does not consolidate their boundaries. We clarify them here: Manifold refers to the locally linear yet globally nonlinear property of the correction geometry induced by the local decoder. We do not aim at global anatomical reconstruction or theoretical optimality, but focus on a concrete algorithm that fully exploits this manifold property for the applications. The local-energy analysis bounds decoded correction energy under stated assumptions. In the manuscript, our ablations provide empirical support. The exponential gate is a deterministic consistency score, not a calibrated probability: both candidates may fail together, and stereo-scale alignment depends on the current stereo estimate.
The evidence remains consistent: full refinement improves EPE from 3.55 for the parameter-matched one-step update to 3.05; path-energy regularization improves 3.84 to 3.05; and spatial gating improves 3.30 with uniform mixing to 3.05. Four stereo backbones yield 3.05-3.22 EPE, so the gain is not backbone-specific. The gate diagnostic further shows localized high-monocular allocation in ambiguous regions. We will state these scope conditions with the supporting evidence and prepared visualizations in the revised manuscript.
The complete efficiency comparison under the same measurement protocol is:
Our model requires 275.54 ms per stereo pair (3.63 FPS) and 2.52 GiB peak memory. Its 8.52T FLOPs are lower than Selective-Stereo (9.06T) and RAFT-Stereo (10.28T), while its latency remains in the same range as their 234.13/240.35 ms. At this comparable computational level, Manifold-Stereo reduces their SCARED EPE from 4.12/4.14 to 3.05 px and their SERV-CT EPE from 5.21/3.24 to 1.70 px, providing substantially stronger endoscopic disparity accuracy without a disproportionate increase in computation. Deployment at higher throughput is feasible with sufficiently provisioned computing resources.