- Rating
- 4
- Clarity
- 3
- Confidence
- 5
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This work focuses on addressing the challenges during the in densification and pruning process of 3DGS. Existing densification strategies mainly depend on first-order screen-space gradients as a reference, which is insufficient for accurately recognizing geometric discontinuities. To solve this issue, this work proposes to utilize second-order depth gradients to control the densification stage. In addition, Multi-view Photometric Error Gating is designed to incorporate the photometric signal into densification, which is particularty beneficial for texture-rich flat regions. Furthermore, this work applies dynamic thresholding strategy for densification and pruning.
Experimental results demonstrate that the proposed method generates fewer Gaussians compared to other methods, while achieving comparable accuracy.
Strengths and weaknesses
Strengths:
- The work presents an interesting method for Gaussian Densification, utilizing the second-order depth responses to guide the densification for depth discontinuities. Besides, this work also introduces Multi-view Photometric Error Gating, facilitating densification in texture-rich flat regions.
- The proposed method is parameter-efficient, with much fewer number of Gaussians and comparable performance compared to existing methods.
Weaknesses:
- This work leverages second-order depth responses, which are friendly for geometry. However, there is no evaluation on geometry-related tasks, such as depth estimation or surface reconstruction, to verify whether the 3D Gaussian representation indeed yields improved geoemtric accuracy.
- In Table 4, two hyperparameters are varied simultaneously across the three settings, making it difficult to analyze the individual influence of each hyperparameter.
- It would be valuable to include an additional ablation study that replaces Eq. 2 with the first-order depth gradient. Such a comparison would provide stronger evidence for the effectiveness of Curvature-Guided Asymmetric Densification.
Questions
What value is used for the quota ratio in Eq. 13 throughout the experiments?
Limitations
Yes
Paper formatting concerns
No
Final justification
This work introduces a novel method that uses the second-order depth responses to guide the Gaussian densification. It has an obvious advantage in terms of the number of Gaussians. Therefore, I tend to accept this paper for NeurIPS.
We sincerely thank the reviewer for the constructive comments and positive assessment of our work. We appreciate the reviewer’s recognition of the motivation and parameter efficiency of ACD-GS, particularly the use of second-order depth responses for geometry-aware densification and the complementary role of Multi-view Photometric Error Gating.
[W1] We appreciate the reviewer’s suggestion regarding geometry-related evaluation. To verify whether the proposed geometry-aware densification preserves reconstructed geometry, we conduct an additional surface reconstruction evaluation. Specifically, we extract meshes from the reconstructed Gaussian representations and evaluate them using Precision, Recall, and F-score.
Our method primarily aims to obtain a more compact Gaussian representation while maintaining comparable novel-view synthesis quality, without introducing additional geometric supervision or explicit constraints on reconstruction accuracy. ACD-GS uses only approximately 38% and 41% of the Gaussian primitives required by AbsGS and GDAGS, respectively. Moreover, because ACD-GS tends to represent planar regions with fewer and larger Gaussians, TSDF-based surface extraction may be more susceptible to holes and local reconstruction errors. Nevertheless, ACD-GS still achieves competitive geometric reconstruction quality, indicating that curvature-aware densification preserves essential scene structures despite the substantially reduced Gaussian budget.
[W2] We agree with the reviewer that varying two hyperparameters simultaneously makes it difficult to isolate their individual effects. We will therefore revise the ablation study in Table 4 to analyze each hyperparameter separately and provide a clearer assessment of its contribution.
The current results already demonstrate that the selected configuration achieves the best balance between rendering quality and compactness:
Although different parameter settings can achieve similar rendering quality, α=0.8,β=1.5 provides the most favorable trade-off, achieving the smallest model size while maintaining competitive image quality. Therefore, we use this configuration in all experiments.
[W3] We appreciate the reviewer’s suggestion of comparing the proposed curvature response with first-order depth gradients. We have already conducted this comparison, and the results are summarized below:
Both variants achieve comparable rendering quality, while curvature-guided densification reduces the model size by approximately 13.5%. First-order depth gradients respond to general depth variations, including approximately constant slopes on smoothly tilted surfaces, which may cause unnecessary densification in such regions. In contrast, second-order depth responses are less sensitive to linear depth variations and emphasize changes in the local depth slope, enabling a more compact allocation of Gaussian primitives.
Nevertheless, second-order differentiation can also amplify depth noise in some regions. Combining first- and second-order depth cues may therefore provide a promising direction for improving the robustness of geometry-aware densification.
[Q1] The quota ratio in Eq. 13 is fixed to μ=0.008(0.8%) throughout all experiments. This parameter controls the proportion of candidate Gaussians considered during the capacity-constrained densification process.
We further evaluate the influence of different quota ratios. The corresponding results are shown below and will be included in Table 4 of the revised manuscript.
The results show that μ=0.008 provides the best overall trade-off between rendering quality and representation compactness. Although μ=0.004 yields a marginally smaller Gaussian count and model size, μ=0.008 achieves higher PSNR and SSIM with the same LPIPS. Increasing the quota ratio to μ=0.012 introduces more candidate Gaussians but provides no additional quality improvement. We therefore use μ=0.008 as the default setting in all experiments.
We sincerely thank the reviewer again for the valuable feedback. These suggestions help us improve the experimental completeness and presentation of ACD-GS.
[1]Ye, Zongxin, et al. "Absgs: Recovering fine details in 3d gaussian splatting." Proceedings of the 32nd ACM international conference on multimedia . 2024.
[2]Kerbl, Bernhard, et al. "3d gaussian splatting for real-time radiance field rendering." ACM Trans. Graph. 42.4 (2023): 139-1.
[3]ZHOU Z, XIONG Y J, ZHANG J C, et al. Gradient-Direction-Aware Density Control for 3D Gaussian Splatting The Fourteenth International Conference on Learning Representations. 2026.
[4]Fang, Guangchi, and Bing Wang. "Mini-splatting: Representing scenes with a constrained number of gaussians." European conference on computer vision. Cham: Springer Nature Switzerland, 2024.
[5]Yu, Zehao, et al. "Mip-splatting: Alias-free 3d gaussian splatting." Proceedings of the IEEE*/CVF conference on* computer vision and pattern recognition . 2024.
[6]Zhang, Zheng, et al. "Pixel-gs: Density control with pixel-aware gradient for 3d gaussian splatting." European Conference on Computer Vision . Cham: Springer Nature Switzerland, 2024.