- Rating
- 5
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper considers the problem of uncertainty attribution in the context of conformal prediction for regression tasks. Given a confidence interval around a predicted output constructed with conformal quantile regression, the authors aim to identify input features that are responsible for the width of this confidence interval. To this end, they propose a decomposition of the width into a test instance-dependent term and a calibration set-dependent term, with each term comprising a different source of uncertainty that contributes to the confidence interval width. With this decomposition at hand, the authors suggest the use of SHAP values to compute feature attribution scores for each of these terms as well as the total attribution score of each feature. Further, they extend their method by showing that their decomposition remains valid for other conformal prediction methods and local attribution scoring rules, as long as they satisfy a certain separability property. Experiments with synthetic and real data show that the proposed decomposition reveals that the attribution score of same feature may be contradicting for each source of uncertainty, a behavior not apparent under total attribution that could mislead human decisions driven by uncertainty attribution.
Strengths and weaknesses
The idea of feature attribution with respect to prediction uncertainty measures such as confidence intervals is rather interesting in general, especially in high-stakes decision making. In this regard, the paper’s approach on decomposing this attribution accounting for different sources of uncertainty appears quite helpful and exciting as it shows potential to provide insightful assistance to expert decision-makers such as clinicians. This approach could spark the interest for further research, going beyond regression tasks. Further, the proposed methods seem rather flexible in practice as they are agnostic to the local attribution scoring rule as well as they allow for several conformal methods.
The work seems overall nicely written. The contributions are well motivated and appropriately placed into contemporary literature, acknowledging prior and concurrent works that also use games [10] and SHAP values [13] (the numbers are consistent with the paper’s references). The notation is clearly introduced and the theoretical results of Theorem 1, and Propositions 1 and 2 seem correct. In addition, the authors provide a brief but detailed analysis of the computational cost regarding the SHAP values in Appendix A.3 that seems rather informative and helpful for research building upon the proposed methods and is thus greatly appreciated—perhaps the authors may like to include it in the main.
The experimental evaluation appears sufficient, including synthetic and semi-synthetic setups that are clearly described. The results demonstrating that the same features may attain attribution scores with opposite signs for the test instance and calibration set attribution appear quite interesting and perhaps somewhat surprising.
Questions
-
While an intuitive interpretation of the test instance uncertainty may be easy to convey---as the authors do with the example in lines 174-175---the interpretation of the calibration-side uncertainty may be a bit harder to convey, especially to non-experts on uncertainty quantification methods. As a result, it would be useful to provide more intuition on the significance of the calibration-driven uncertainty. An intuitive example could help, along the lines of the example in lines 174-175.
-
The authors may like to bring the cost analysis in Appendix A.3 in the main as it can be rather informative for future works building upon the proposed methods.
Limitations
yes
Paper formatting concerns
No major formatting concerns
Final justification
Other than the paper being well written based on solid and interesting theoretical as well as experimental results on the first place, the authors seem to have addressed the concerns of all reviewers. Therefore, I will keep my current score.
Intuition for the calibration-driven component (Q1).
Thank you for this helpful suggestion. The calibration-side component is the part of the interval width contributed by the conformal calibration step, which every test point carries. Where the clinician of lines 174-175 asks “would an action on feature j for this patient reduce my uncertainty?" and is querying ϕn+1,jL, the counterpart question for ϕjG is "does feature j, across the cohort we calibrated on, reduce the width that the calibration step contributes to every prediction?" A substantial ϕjG is in this sense a pipeline-audit signal, and can point to calibration residuals associated with feature j, the representativeness of the calibration cohort, or the adequacy of the fitted model and conformity score.
The Bike Sharing instance shows the two questions receiving opposite answers. On the calibration side the hour feature is uncertainty-reducing (ϕhrG=−125.6). On the instance side the same feature is uncertainty-increasing for this test point (ϕhrL=+125.2).
One caution is worth stating. A large ϕjG should not be read as evidence that feature j carries more irreducible variability in the data-generating process. Our split is procedural rather than statistical (Sec. 7): ϕjG reports how feature j moves the calibration-side width under a given fitted model, calibration sample, score function, and masking convention, and can change when any of these change. It indicates where to look, not what the underlying variability is. We will add this interpretation and caveat to Sec. 4.2.
On the placement of cost analysis (Q2).
Thank you for this helpful suggestion. We will move a concise version of the computational-cost analysis from Appendix A.3 to the end of Sec. 4, including the exact and sampled complexities and the amortization enabled by caching ϕG. We will revise Sec. 6.2 to focus on empirical scalability, incorporating the key runtime and high-dimensional scaling results from Appendix B.5 while retaining the detailed experimental settings in the appendix.