- Rating
- 5
- Clarity
- 3
- Confidence
- 2
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper introduces Stochastic Grouping Conformal Prediction (SGCP) to address the critical limitation of standard conformal prediction, which guarantees uncertainty only at the population level and often fails to provide reliable coverage for minority subgroups. Instead of relying on explicit sensitive attributes like race or gender to calibrate subgroups separately, which can lead to inflated, uninformative prediction sets due to limited data, SGCP learns a latent structure that automatically organizes samples based on their inherent calibration behavior. When processing a new patient, the model stochastically maps the patient across these latent components, allowing for flexible and shared calibration. This approach mathematically preserves the standard overall coverage guarantee while empirically boosting the reliability of predictions for underrepresented groups without requiring demographic data.
Strengths and weaknesses
Strengths High Clinical Practicality (Privacy-Preserving Fairness): The motivation to achieve subgroup reliability without requiring explicit access to sensitive attributes (e.g., race, gender, socioeconomic status) is highly commendable. In real-world clinical settings, demographic data is often incomplete, noisy, or legally restricted. SGCP provides an elegant, privacy-preserving workaround by organizing samples based on their inherent "calibration behavior" rather than predefined labels.
Elegant Mitigation of the Worst-Group Bottleneck: Standard group-conditional conformal prediction often suffers from inflated prediction sets due to limited sample sizes in minority groups. SGCP addresses this structural bottleneck beautifully. By introducing a stochastic grouping map, the framework allows flexible sharing of calibration information across latent components, effectively balancing subgroup reliability with prediction set efficiency (reducing cognitive burden for clinicians).
Weaknesses The paper promotes "subgroup reliability" as its primary contribution. However, the theoretical proof provided only guarantees marginal (population-level) validity (Eq. 1), which is the exact same guarantee provided by standard conformal prediction. The absence of a formal mathematical proof for finite-sample conditional or subgroup-level coverage creates a significant gap between the paper's conceptual narrative and its mathematical substance.
The mechanism relies on mapping patients to a "latent calibration structure." In medical decision-making, transparency is critical. If a patient is assigned an unusually large prediction set, a clinician has no way to interpret why or to understand what specific "latent group" the patient was probabilistically assigned to. This black-box grouping limits the trustworthiness of the uncertainty quantification.
Questions
While the paper proves marginal coverage, standard conformal prediction already achieves this. Is it possible to provide a theoretical bound (even a relaxed or asymptotic one) for the coverage guarantee specifically within the learned latent subgroups?
In a clinical deployment, how can a medical professional interpret the latent groups?
The framework relies on drawing calibration information from "a small set of latent calibration components." How is the optimal number of these components structurally determined, and what happens if this hyperparameter severely mismatches the true underlying heterogeneity of the patient population?
Limitations
No limitations addressed.
Paper formatting concerns
,
Final justification
I thank the authors for the detailed rebuttal. The clarification regarding Proposition 3 adequately addresses my main theoretical concern about finite-sample subgroup bounds. Furthermore, the post-hoc analysis on the MIMIC-IV dataset and the explanation of K as a resolution parameter parameter provide sufficient reassurance regarding interpretability and robustness. The authors successfully addressed my concerns, and I will raise my score accordingly.
Thank you very much for the careful review. We appreciate the opportunity to clarify these points below.
W1&Q1. Finite sample coverage within subgroups
A1. We especially appreciate your recognition of SGCP's practical value. Your main theoretical concern is whether SGCP goes beyond marginal validity. It does, and we answer this directly below.
In fact, the submitted paper already provides a finite sample subgroup guarantee, although we agree that Proposition 2 received more attention in the presentation, which made the subgroup result too easy to miss.
Proposition 3 in the main paper, with its proof in Appendix A.3, applies to any fixed measurable subgroup G. Let V=F(s(X,Y)∣X) and define $\Delta_G := \sup_{t\in[0,1]} \left| \Pr(V\leq t\mid X\in G) -\Pr(V\leq t) \right|$.
Thus, ΔG measures the mismatch between the subgroup and population distributions of the transformed score. Write CovG for coverage conditional on Xn+1∈G. Let m=∣Dcal∣ and $k=\lceil (m+1)(1-\alpha)\rceil $. Under calibration-test exchangeability conditional on Dtra and continuity of the marginal law V, Proposition 3 gives $|\mathrm{Cov}_ G-\frac{k}{m+1} | \leq \Delta_G $, and hence subgroup coverage is at least 1−α−ΔG.
Remark 3 connects this bound directly to the oracle local score law Fx⋆. Under the conditional-score continuity condition of Proposition 1 (for brevity, we omit the conditioning on Dcal in the notation),
$\sup_{x,t} \left|\widehat F(t\mid x)-F_x^\star(t)\right| \leq\varepsilon \quad\Longrightarrow\quad \Delta_G\leq2\varepsilon$.
Consequently,
$\left| \mathrm{Cov}_G -(1-\alpha) \right| \leq2\varepsilon+\frac{1}{m+1}$.
Because this statement holds for any fixed measurable G, it also applies to component-induced audit regions whose routing rule is fixed before calibration. The key point is direct: as SGCP better approximates the oracle local score law, its finite-sample subgroup bound tightens, while the independent conformal step preserves marginal validity.
We would also like to be precise about what the theorem does not claim. It is not exact distribution free conditional coverage, and the bound may be loose when the learned local score law is inaccurate and ΔG is large. This is a substantive limitation, and we do not wish to obscure it. Even so, the proposition provides theoretical support for subgroup reliability beyond the usual marginal CP guarantee.
To recap. For subgroup-aware methods, the guarantee is usually established for a prespecified group G: once G is known, the method can provide a direct coverage guarantee for that group, rather than merely an upper bound on its coverage error. Perhaps this is the setting you had in mind. SGCP operates under a considerably more demanding information regime. At no point during learning or calibration is it given any knowledge of the subgroup whose reliability it is ultimately expected to improve. Establishing an exact subgroup-level guarantee under such conditions is therefore far from straightforward. We are grateful that you anticipated this difficulty. Given the information available to SGCP, Proposition 3 represents the strongest guarantee that we can presently establish. We believe, however, that the empirical evidence offers an important complementary perspective. Across nearly all of our experiments, SGCP yields clear improvements in subgroup coverage, supporting its practical effectiveness even where a stronger theoretical guarantee remains elusive.
We hope this clarification addresses your principal theoretical concern.
W2&Q2. Clinical interpretation of the latent components
A2. This is an excellent question. We share your concern that a latent component should not be presented as a clinical explanation simply because it has a distinct density. We want to clarify what is and is not observable in SGCP.
First, SGCP does not assign a patient to a single latent group, nor does it apply a hidden group specific threshold. Instead, each patient receives a soft weight vector over recurring nonconformity score distributions. For a patient x and candidate label y, the transformed score is Vy(x)=∑kwk(x)Fk(s(x,y)).
This decomposition is directly inspectable. For every candidate label, a clinician or auditor can examine the original nonconformity score s(x,y), the patient specific weights wk(x), the percentile assigned by each component Fk(s(x,y)), each contribution wk(x)Fk(s(x,y)), and the final comparison with the shared conformal cutoff. An unusually large prediction set arises when more candidate labels are retained after this comparison, and the contribution of each learned score regime to every inclusion decision can therefore be traced.
We agree, however, that this is an operational explanation in score space, rather than an immediate clinical explanation of why a patient is difficult to predict. To investigate whether the learned structure nevertheless has stable and meaningful properties, we conducted a post hoc component audit using the five runs from the MIMIC-IV temporal transfer experiment. After aligning components across runs, the three target regimes exhibit increasing mean true label scores, top 1 error rates, and average prediction set sizes. Their prevalence also changes substantially from the source to the target cohort, revealing a temporal shift toward the more difficult calibration regime.
The learned structure is also reasonably reproducible. All three components remain active, the median matched soft agreement across ten seed pairs is 0.884, and the median hard assignment ARI is 0.751. We additionally observe associations between the components and recorded patient characteristics, such as insurance status. We treat this as a preliminary finding, and rigorous interpretation requires further work.
All told, our view is that SGCP is not opaque at the level of the calibration mechanism. Each label inclusion decision has a patient level audit trail. At the same time, translating these recurring score regimes into clinically meaningful explanations requires dedicated clinical analysis.
Q3. How is K determined, and what happens when it is misspecified?
A3. We want to clarif that K is a resolution parameter, not a claimed number of demographic or clinical populations. If K is misspecified, it may affect how accurately SGCP represents the local score law and may therefore reduce its subgroup reliability or efficiency gains. Importantly, however, such misspecification does not invalidate the finite sample marginal coverage guarantee, because the final cutoff is still estimated on an independent conformal calibration split.
More specifically, a smaller K gives a coarser description of score heterogeneity; with a larger K, the soft mixture can refine or overlap existing regimes rather than forcing patients into a hard partition. We checked K∈{3,6,9,12} directly. As mentioned in Figures A11–A12, a moderate K already captures the main low- and high-score regimes, while extra components mostly refine or overlap them. Figures A13–A14 show stable coverage, AvgSize, and CovGap across all four choices, so the result does not depend on a delicate value of K.
Result. These findings suggest that SGCP is robust to moderate misspecification of K, but they do not identify a unique structural value.
Thank you again for pressing us on these points. The questions helped us see that the marginal guarantee, the relaxed subgroup result, and the empirical subgroup claim were too easy to conflate. We hope the bound and component analysis clarify both what SGCP provides and what it does not. We hope that our answers can ease your concerns. If there are any other concerns, we also very happy to continue our discussion. Thank you!!!