- Rating
- 3
- Clarity
- 4
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
This paper presents Rat NCAP, a biologically grounded locomotion controller for an anatomically realistic rat simulator. Building on spinal circuit priors, the authors extend NCAP to a more complex rat body and introduce a flexor-extensor neuromechanical interface together with an improved ES-based training pipeline. The resulting model learns multiple gaits without imitation learning and reproduces several known locomotion statistics and cell-type ablation phenomena reported in prior neuroscience studies.
Strengths and weaknesses
This paper is well written and technically solid. The motivation is clear, and the integration of biologically inspired circuit priors with embodied simulation is interesting. In particular, the cell-type-level architecture provides a level of interpretability that is difficult to obtain with standard black-box controllers.
I have several concerns regarding the evaluation and the strength of the claims.
- One of the main advertised contributions is the transition from a simplified quadruped controller to a more anatomically realistic 38-DOF rat body. However, the paper does not convincingly demonstrate that the additional DOFs are functionally exploited by the learned policy. Qualitatively, many body parts (e.g., tail, neck, trunk) appear largely passive, and locomotion seems to rely primarily on limb coordination. A body-DOF ablation (e.g., fixing/removing tail or spine joints) would help justify the necessity of the increased biomechanical complexity.
- The conclusion that the proposed flexor-extensor interface is superior is not entirely convincing. Torque control fails while the other interfaces succeed, but it is unclear whether this is due to the interface itself or because the structured NCAP architecture is not well suited for direct torque prediction. The current experiments do not disentangle these two factors.
- Although the paper claims naturalistic locomotion, the evaluation mainly focuses on gait timing and step statistics. I would like to see more comprehensive whole-body kinematic analysis. In the provided results, head stabilization, trunk motion, and tail dynamics appear limited compared with real rodents. The current evidence supports biologically plausible gait generation, but not necessarily biologically realistic full-body motion.
- The in-silico ablation experiments are interesting but mostly reproduce known findings from prior neuroscience literature. It would be more impactful if the model could generate new experimentally testable predictions beyond validating established phenomena.
Questions
- Can the authors perform a body ablation study by fixing or removing subsets of DOFs (e.g., tail, spine, neck) to quantify whether the additional anatomical complexity materially contributes to locomotion quality?
- How can the authors distinguish whether the failure of torque control is caused by the neuromechanical interface itself versus the inductive biases imposed by the NCAP architecture? Would comparisons with a less constrained controller help?
- Can the authors provide additional quantitative whole-body kinematic analyses (e.g., tail motion, trunk oscillation, head stabilization) or comparisons against motion capture data to support the claim of naturalistic locomotion?
- Beyond reproducing known V0v/V0d ablation results, can the framework generate novel biological predictions that could be experimentally validated?
- To what extent can the proposed pipeline scale to more realistic full-body rodent motion? For example, could it recover coordinated tail, trunk, and head dynamics similar to existing virtual rodent systems, or is its scope mainly limited to gait generation?
Limitations
No major concerns. The authors discuss several limitations and future directions.
Paper formatting concerns
None
Final justification
The rebuttal adds several useful analyses and clarifies the intended scope, but it does not fully resolve my main concerns. In particular, the functional contribution of the additional biomechanical complexity remains insufficiently demonstrated, the torque-control results do not disentangle interface limitations from architecture compatibility, and the new perturbation analyses provide limited evidence for stronger mechanistic claims. Overall, I view the work as technically solid and interesting, but the current evidence does not sufficiently support its broader claims. I therefore revise my rating from 4 (Borderline Accept) to 3 (Borderline Reject).
Meta-review
This paper is heading towards acceptance with all three reviewers recommending acceptance. While experimental validation of the model is likely out of scope for this conference, other suggestions by reviewers would likely strengthen the paper.