- Rating
- 3
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 2
Read review
Summary
The paper proposes Temporal Prototype Alignment (TPA), a dataset distillation framework targeting the memory bottleneck of frozen-feature methods like Linear Gradient Matching (LGM). Instead of spatially averaging gradients across many augmented views (spatial Monte Carlo ensembling), TPA accumulates gradient signals across optimization steps via a temporal prototype estimator. An adaptive momentum gate controls how much the estimator trusts local gradient signals based on reliability. Additionally, a consensus alignment objective leverages multiple pretrained teachers to improve cross-architecture transfer.
Strengths and weaknesses
Strength:
- Reframing spatial ensembling as a temporal estimation problem is a clean and well-motivated conceptual contribution.
- The method substantially reduces memory and computational overhead.
- Contrastive consensus alignment distills architecture-agnostic consensus knowledge from heterogeneous foundation models.
Major Weakness:
- The temporal estimator accumulates gradients across optimization steps where parameters are continuously shifting, which introduces a potential statistical bias. Gradients at different timesteps reflect different parameter states and may not be exchangeable. The bias correction in Eq. 6 addresses initialization bias from the EMA but does not characterize whether the estimator converges to the same target as spatial averaging under non-stationary parameters.
- InfoNCE / mutual-information formulation needs clearer dimensions.
- The comparison baseline set is narrow. LGM is the primary baseline, but a broader set of recent frozen-feature and non-frozen distillation methods (e.g., RDED, SRe²L, CAFE) are absent.
- The paper lacks component-level ablation. It is unclear how much each of the two core contributions, the temporal prototype estimator and the consensus alignment objective, independently contributes to the gains.
- The adaptive momentum gate ablation in Figure 7 varies threshold hyperparameters but does not include a baseline without any gate.
Questions
How does TPA perform under higher IPC settings such as IPC=10 or IPC=50?
Limitations
No. The limitation paragraph is about the LGM baseline and there is no limitation for the approach in this paper. The temporal estimator may introduce bias under faster optimization schedules, which is not discussed.
Paper formatting concerns
The text wraps around Figure 1, Figure 4, Table 5, and Table 6.
Final justification
The rebuttal makes some additions: component-level ablations separating temporal reuse, adaptive gating, and reliability normalization, explicit InfoNCE/MI dimensions, and broader RDED/SRe²L comparisons under a shared evaluator. The theoretical bias analysis under non-stationary parameters remains unresolved, as the derived bound does not cover the data-adaptive gating actually used in Full ATM. IPC=10 and IPC=50 also remain untested. Most new ablation and comparison results are also single-run without cross-seed variance.
We sincerely thank the reviewer for recognizing the conceptual reframing, efficiency gains, and cross-architecture motivation. We agree that the original paper should have made the estimator's statistical target, CCA dimensions, component controls, broader context, and TPA-specific limitations more explicit.
W1. Statistical bias under non-stationary parameters
Thank you for highlighting this important distinction. We agree that Eq. 6 only removes EMA initialization bias and is not a general correction for non-stationarity. However, this source of target drift does not arise in the same form under our real-gradient sampling protocol. The encoder is frozen, and the linear head is freshly sampled from the same fixed distribution at every distillation step rather than updated from the previous head. The same sampled head is used for the paired real and synthetic gradients within that step. Updating the synthetic images therefore does not alter the distribution of the real-gradient target.
For a time-varying expected target μt, the lag bias of an estimator with nonnegative normalized weights at,s is bounded by
\leq \rho\sum_{s\leq t}a_{t,s}(t-s),$$ when $\\|\mu_s-\mu_t\\|\leq\rho|t-s|$. Longer memory lowers sampling variance but may increase lag. This characterization applies to deterministic or history-predictable weights. We do not claim that data-adaptive Full ATM converges to the unweighted spatial mean. In the ten-observation diagnostic, Spatial $K=10$ varies augmentation for one batch and head, whereas Uniform Temporal Mean resamples the batch, augmentation, and head across steps. The latter reaches 0.8302 cosine to a disjoint 512-observation raw reference versus 0.5027 for $K=10$. This unweighted control targets raw fidelity, while Full ATM intentionally constructs an inverse-RMS-normalized direction. We audited a saved ImageNet-100/CLIP Full-ATM trajectory (batch size 256, 5,000 steps, seed 3407) against an independent 512-observation native inverse-RMS reference: | Stage | Native-reference cosine $\uparrow$ | Tracking error $\downarrow$ | SI-MSE $\downarrow$ | |---|---:|---:|---:| | Early (100/500) | 0.9074 | 0.0926 | 0.1733 | | Middle (1,000/2,000) | 0.9757 | 0.0243 | 0.0480 | | Late (3,000/4,000/5,000) | **0.9824** | **0.0176** | **0.0348** | At step 5,000, reference cosine is 0.9830 and SI-MSE is 0.0337. We observe no late-stage accumulation of lag in this trajectory. This is empirical evidence for the tested frozen setting, not a convergence guarantee for rapidly trained teachers or probes. We will clarify that Eq. 6 corrects initialization only, add the variance-lag analysis and trajectory audit, and list fast target drift as a limitation. ### **W2. Dimensions of the InfoNCE/MI formulation** Thank you for asking us to make the dimensions explicit. For teacher $m$, the linear head has shape $C\times F_m$. Its real prototype $G_m$ and class-wise synthetic gradient $\nabla_{W_m}\ell_{\mathrm{syn}}$ both have shape $C\times F_m$. Row-wise cosine similarities produce a teacher-local $C\times C$ logit matrix. Row $c$ compares synthetic class $c$ with all $C$ real class prototypes. The diagonal is the matched-class positive, and off-diagonal entries are negatives. Cross-entropy is applied row-wise, after which the teacher-local losses are uniformly summed. No dot product is taken across teachers, so CLIP, DINOv2, and MoCo-v3 need not share $F_m$. Each teacher has its own head and prototype. Only the synthetic pixels are shared. We will add all tensor dimensions and the positive/negative construction immediately below Eqs. 8-10. ### **W3. Broader comparison with RDED, SRe\$^2\$L, and CAFE** Thank you for suggesting these broader comparisons. We reproduced RDED and SRe\$^2\$L on ImageNet-100 at IPC=1. The resulting hard-label sets were evaluated under a shared frozen-feature linear-probe protocol using CLIP, DINOv2, and MoCo-v3, with 1,000 training epochs and seed 3407: | Method | CLIP | DINOv2 | MoCo-v3 | Avg. | |---|---:|---:|---:|---:| | SRe\$^2\$L | 55.70 | 78.08 | 62.68 | 65.49 | | RDED | 69.20 | 79.84 | 71.84 | 73.63 | RDED and SRe\$^2\$L were developed for train-from-scratch evaluation, and SRe\$^2\$L natively uses recovered images with soft labels and FKD. We therefore present the table as transparent cross-paradigm context under a common hard-label evaluator rather than as a replacement for their native-protocol results. CAFE was evaluated in a low-resolution train-from-scratch setting (28×28 or 32×32), and its paper lists ImageNet as future work. We therefore could not identify an official ImageNet-100 artifact or recipe compatible with our frozen-feature hard-label evaluator. Rather than report a mismatched reconstruction, we provide the reproducible RDED and SRe\$^2\$L results. LGM remains the closest protocol-matched baseline. We will add this table together with a protocol taxonomy distinguishing native train-from-scratch evaluation, cross-paradigm frozen-feature re-evaluation, and protocol-matched LGM. ### **W4-W5. Component contributions and the missing no-gate baseline** Figure 7 varies $\mu_{\min}$ and $\mu_{\max}$ only within the gated family and therefore does not isolate the gate itself. We add Uniform Temporal Mean as a gate-free baseline and Static EMA as a fixed-retention baseline without adaptive gating. To isolate the temporal components, we fixed ImageNet-100, IPC=1, CLIP teacher, batch size 256, 5,000 steps, InfoNCE, initialization, and seed 3407, changing only the target estimator. Each resulting CLIP-distilled synthetic set received one fixed evaluation on each of the three frozen backbones. Here, “C/D/M evaluator mean” is the arithmetic mean of the CLIP, DINOv2, and MoCo-v3 Top-1 accuracies obtained by evaluating the same CLIP-distilled synthetic set. | Estimator | CLIP | DINOv2 | MoCo-v3 | C/D/M evaluator mean | |---|---:|---:|---:|---:| | Raw $K=1$ | 75.96 | 75.58 | 63.33 | 71.62 | | Uniform Temporal Mean (no decay/gate) | 80.63 | 79.03 | 68.58 | 76.08 | | Static EMA (no adaptive gate) | 80.14 | 81.51 | 68.60 | 76.75 | | Adaptive Mean (gate, no inverse-RMS) | 83.80 | 81.23 | 69.06 | 78.03 | | Full ATM | **86.03** | **82.73** | **70.94** | **79.90** | Uniform Temporal Mean improves the C/D/M evaluator mean from 71.62 to 76.08 over raw $K=1$, showing that temporal reuse is beneficial even without a gate. Static EMA reaches 76.75, while replacing its fixed retention with adaptive gating raises the point estimate to 78.03. Full ATM further reaches 79.90 after adding inverse-RMS reliability normalization. To isolate the alignment objective, we separately fixed ImageNet-100, IPC=1, C+D+M, uniform teacher aggregation, Full ATM, 5,000 steps, and seed 3407, changing only the alignment objective: | Objective | CLIP | DINOv2 | MoCo-v3 | C/D/M evaluator mean | |---|---:|---:|---:|---:| | Global cosine | 84.42 | 91.16 | 85.60 | 87.06 | | Relative MSE | 84.28 | 92.22 | 84.44 | 86.98 | | InfoNCE | **86.94** | **92.38** | **86.32** | **88.55** | Each objective was evaluated once under the same fixed protocol. The resulting point estimates show that InfoNCE improves the C/D/M evaluator mean over global cosine by 1.49 points. This controlled comparison shows that alignment geometry affects the transfer trade-off. CCA's structural contribution is aligning teacher-local class relations through shared synthetic pixels. We will supplement Figure 7 with these orthogonal component and no-gate controls, explicitly separating temporal reuse, fixed retention, adaptive gating, inverse-RMS reliability normalization, and alignment geometry. ### **Q1. Higher IPC, including IPC=10 or 50** The Appendix reports IPC=5. For a matched comparison, we additionally evaluated ImageNet-100 at IPC=1 and IPC=5 with batch size 256, $K=1$, Full ATM, 5,000 steps, and one fixed evaluation run per synthesized set: | Distillation teacher | IPC=1 source-matched | IPC=5 source-matched | Change | |---|---:|---:|---:| | CLIP | 86.52 | **87.80** | +1.28 | | DINOv2 | 92.00 | **92.86** | +0.86 | | MoCo-v3 | 85.84 | **86.62** | +0.78 | | Average | 88.12 | **89.09** | +0.97 | All three source-matched results improve at IPC=5. This increases synthetic-set capacity fivefold and provides direct evidence that TPA scales beyond the one-image regime. The average gain is 0.97 points under the fixed 5,000-step budget. Submitted Table 13 separately provides the five-run IPC=5 comparison with LGM. We will add a matched IPC=10 evaluation in the revision. IPC=50 remains untested. ### **W6. TPA-specific limitations** We agree that the current paragraph discusses LGM rather than limitations of TPA. We will add a dedicated section stating: 1. **Supervised and frozen-target scope.** CCA relies on class identities, and ATM is evaluated with frozen teachers and freshly sampled probes. Self-supervised targets or rapidly updated teachers and probes may require new positive-pair construction or shorter-memory estimators. 2. **Finite synthetic capacity and scaling.** Under fixed IPC, conflicting teachers can compete for limited synthetic capacity, so adding teachers need not improve every class or evaluator. Synthetic-data storage and optimization cost also grow with IPC. We validate IPC=5 but not IPC=10 or 50. ### **W7. Formatting** Thank you for identifying the wrapping around Figures 1 and 4 and Tables 5 and 6. We will remove text wrapping and use standard full-width float placement throughout the revision. We appreciate that these questions prompted us to sharpen the estimator's statistical scope, disclose the no-gate and objective controls, broaden the comparison, and state TPA's limitations directly.