This paper proposes CardioFAD, a Focus–Align–Diffuse framework for synthesizing dense cardiac dynamics from extremely sparse visual observations, such as a single CMR slice/volume or a single ECHO frame, with auxiliary time-series signals such as ECG. The authors reformulate sparse cardiac dynamic synthesis as a recoverability–alignability anchor discovery problem. Specifically, the Focus module learns motion-salient keyframes under a Trajectory Sufficiency Principle, the Align module encourages keyframe-weighted ECG–visual alignment under an Anchor Alignment Principle, and the Diffuse module performs two-stage generation by first synthesizing keyframes and then interpolating non-keyframes. The method is evaluated on 3D+t CMR synthesis using UK Biobank and 2D+t ECHO synthesis using EchoNet-Dynamic and EchoNet-Pediatric. The reported results show consistent improvements over controllable video generation baselines and ECHO-specific baselines in PSNR, SSIM, LPIPS, FID, and FVD, with additional clinical evaluation using EF estimation on EchoNet-Dynamic.
Strengths and weaknesses
Main Strengths
- Well-motivated problem formulation. The paper addresses an important and challenging clinical problem: reconstructing full cardiac dynamics from extremely sparse observations. The formulation around temporal ambiguity, weak visual evidence, and ECG–visual phase misalignment is convincing.
- Clear and coherent method design. The Focus–Align–Diffuse pipeline is conceptually clean. The decomposition into keyframe discovery, cross-modal alignment, and two-stage generation makes sense for sparse dynamic synthesis. The framework is also visually well explained in Figure 2, where the pipeline is divided into input encoding, Focus, Align, and Diffuse stages.
- Keyframe learning is more principled than simple ED/ES or uniform anchors. The paper does not merely use predefined cardiac phases such as ED/ES. Instead, it learns anchors that are both trajectory-sufficient and ECG-alignable. The ablation shows that learned anchors outperform random, uniform, GT ED/ES, and GT ED/ES supplemented keyframes.
- Good diagnostic analysis. The principle-targeted diagnostics in Section 4.4 are a strong part of the paper. The authors separately analyze whether selected keyframes are trajectory-informative and whether they concentrate ECG–visual alignment, which provides more evidence than standard metric comparison alone.
Main Weaknesses
- The task remains fundamentally ill-posed, and the paper may overstate recoverability. Synthesizing an entire cardiac sequence from a single frame, slice, or volume is extremely underdetermined. Although ECG and learned anchors help, many possible anatomically plausible trajectories may correspond to the same sparse observation. The paper would benefit from more uncertainty-aware evaluation or multi-sample diversity analysis rather than mainly reporting deterministic fidelity metrics.
- The role of ECG is not equally convincing across datasets. For ECHO datasets without ECG, the paper uses a patient-agnostic canonical phase template as a weak pseudo-ECG surrogate. This is practical, but it weakens the central claim that CardioFAD effectively leverages real auxiliary ECG signals. In those settings, the gains may come more from learned cardiac phase priors and two-stage keyframe diffusion than from true ECG–visual alignment.
- Clinical fidelity evaluation is still indirect. EF estimation is useful, but it relies on a separately trained regressor rather than direct clinical annotations, segmentation-derived volumes, or expert assessment. The authors also acknowledge that assessing clinical fidelity of generated CMR without explicit annotations such as segmentation labels or ED/ES phases remains an open challenge.
- Baseline comparison could be stronger. The paper compares with controllable video generation baselines and several ECHO generation methods. However, for a NeurIPS-level submission, it would be helpful to include more specialized cardiac reconstruction, interpolation, or motion-modeling baselines where possible. Some baselines may not be designed for this exact extreme one-shot medical setting, making the comparison less definitive.
Questions
- How much of the performance gain comes from real ECG information versus learned cardiac phase priors, especially on ECHO datasets where pseudo-ECG templates are used?
- Does CardioFAD generate diverse plausible trajectories when sampling multiple times from the same sparse observation, or does it collapse to an average cardiac motion pattern?
- For CMR, can clinical fidelity be evaluated using downstream segmentation, volume curves, ED/ES timing, or strain-related metrics?
- How sensitive is the method to ECG noise, missing ECG segments, arrhythmia, or irregular cardiac cycles?
Limitations
Overall, I find this submission interesting and reasonably strong. The problem is important, the Focus–Align–Diffuse formulation is coherent, and the empirical results are convincing across multiple cardiac synthesis settings. However, I have some reservations. The clinical validity of generated dynamics remains only partially established, the role of real ECG guidance is less clear on datasets using pseudo-ECG, and the framework is currently quite specialized to periodic cardiac motion. The paper would be stronger with more direct clinical metrics, uncertainty analysis, and deeper evaluation under ECG misalignment or pathological rhythms.
Paper formatting concerns
No
The reviewer’s positive assessment of importance of the problem, the clear Focus–Align–Diffuse design, and our diagnostic analyses is greatly appreciated. We add ECG attribution and multi-sample diversity analyses while further clarifying the scope of our clinical claims.
Summary of Key Concerns and Main Responses
W1: Multi-sample uncertainty.
Please see Q2 below.
W2: Gains from pseudo-ECG.
Please see Q1 below.
W3: Clinical fidelity evaluation.
Please refer to Q3.
W4: Baseline comparison.
Thank you for the feedback on our baseline settings. We agree that cardiac reconstruction [1][2], interpolation [3][4], and motion-modeling [5][6] methods are relevant directions. However, these methods typically rely on undersampled acquisition measurements, multiple observed frames or endpoint phases, or full cine sequences, which are unavailable in our extreme single-observation setting. Direct adaptation would therefore require changing their original input assumptions and would not provide a faithful comparison. We will expand the camera-ready Related Work to discuss these methods and clarify the protocol differences, while restricting our empirical claims to approaches evaluated under matched sparse-observation conditions.
Q1: Gains from real ECG information versus learned cardiac phase priors.
We thank the reviewer for highlighting this issue. We agree that the role of temporal guidance differs across datasets: UKBB provides paired patient-specific ECG, whereas the ECHO datasets use only a shared, patient-agnostic phase template. Therefore, the ECHO experiments should not be presented as evidence of real ECG–visual alignment.
To separate these effects, we retrained CardioFAD under matched settings. On UKBB, we compare paired real ECG, subject-shuffled real ECG, a patient-independent canonical training ECG, and null ECG. On EchoNet-Dynamic, we compare the correct phase template, a random-offset template that breaks phase-to-frame correspondence, a null template, and a matched one-stage model using the correct template.
Table R1. Attribution of temporal guidance
As reported, UKBB exhibits a clear hierarchy from paired ECG to shuffled ECG, canonical ECG, and null ECG, showing that generic phase structure is useful while correct patient-specific pairing provides additional gains. On ECHO, the correct template outperforms the random-offset and null templates, and the two-stage model outperforms its matched one-stage counterpart, separating the contributions of valid phase conditioning and keyframe anchoring.
We commit to adding this analysis to the camera-ready version as Appendix C.2, Attribution of Temporal Guidance. Therefore, real patient-specific ECG provides additional gains beyond generic cardiac phase priors on UKBB, whereas the ECHO gains arise from valid generic phase conditioning together with two-stage keyframe diffusion.
To clarify the evidence scope, patient-specific ECG utility is supported only on UKBB, primarily by Table R1 and complemented by the ECG-removal and perturbation analyses in Table 13 and Appendix C.7. The ECHO results support only generic phase guidance and two-stage anchoring; we will revise the relevant claims and terminology throughout the manuscript accordingly.
Q2: Generation Diversity.
We appreciate the reviewer’s careful reading of our manuscript. We agree that one-shot cardiac synthesis is inherently one-to-many, and clarify that our notion of recoverability refers to trajectory reconstruction sufficiency rather than unique identification of the underlying motion. We therefore conduct the complementary analyses as follows.
Table R2. Conditional Fidelity–Diversity Analysis.
CardioFAD shows lower pairwise appearance and motion diversity than the one-stage model, consistent with its phase-anchored design, which trades unconstrained variation for higher reconstruction fidelity and functional stability. We therefore do not claim that CardioFAD captures the complete conditional posterior. Importantly, its residual variation is better localized to difficult frames, as the uncertainty–error correlation increases from 0.29 to 0.50, while LPIPS, EF MAE, and within-case EF variability all improve. Hence, CardioFAD retains non-zero stochastic variation but prioritizes faithful and phase-consistent reconstruction over maximal diversity. We will add the full setup and results to the camera-ready version in Appendix C.6 as a new section entitled Conditional Fidelity–Diversity Analysis and acknowledge limited posterior coverage as a limitation.
In summary, CardioFAD produces lower yet more error-correlated residual variation, reflecting a deliberate fidelity–diversity trade-off rather than comprehensive posterior modeling.
Q3: Clinical fidelity for CMR.
Thank you for this important point. We agree that segmentation-derived volume curves, ED/ES timing, strain, and expert assessment would provide stronger clinical validation. The EF regressor is intended only as complementary functional evidence rather than a substitute for annotation-based evaluation. Reliable CMR assessment would require frame-wise expert segmentations and phase annotations, which are unavailable under our current evaluation protocol. Applying an off-the-shelf segmenter to generated CMR would remain indirect and could confound generation errors with segmentation-domain-gap errors. We will therefore clarify in the camera-ready version that our current CMR experiments assess spatiotemporal generation fidelity rather than comprehensive clinical validity, and explicitly identify annotation-based volumetric, timing, strain, and expert evaluation as important future work.
Q4: Sensitivity to ECG Perturbations.
Thank you for the constructive question. Appendix C.7 evaluates modality-specific perturbations. For CMR, we test Gaussian noise, missing leads, and temporal phase jitter. For ECHO, we test phase shifts, pseudo-ECG component dropout, and random segment masking. These experiments cover noise, desynchronization, and incomplete conditioning, but they preserve regular periodicity and do not model arrhythmia or variable R–R intervals. We therefore do not claim robustness to irregular rhythms and will explicitly note this limitation.
References
[1] Pan J, et al. Unrolled and rapid motion-compensated reconstruction for cardiac CINE MRI. 2024.
[2] Iijima L, et al. EchoPOSE: 6D Pose Estimation of Sparse Echocardiograms for Left-Ventricular 3D Shape Reconstruction. 2026.
[3] Zhou X, et al. A diffusion-driven temporal super-resolution and spatial consistency enhancement framework for 4D MRI imaging. 2025.
[4] Zhang J, et al. Temporal Modulated Multi-scale Deformation Fusion via Knowledge Distillation for 4D Medical Image Interpolation. 2025.
[5] Shen C, et al. Continuous 3D myocardial motion tracking via echocardiography. 2024.
[6] Bi N, et al. Segmorph: concurrent motion estimation and segmentation for cardiac mri sequences. 2024.