- Rating
- 4
- Clarity
- 2
- Confidence
- 5
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
Authors propose CytoWave which is a two-stage pretraining framework for single-cell genetic perturbation response prediction. Stage 1 learns control-cell representations via masked gene recovery; Stage 2 learns an additive latent perturbation operator with an auxiliary InfoNCE objective aligning latent state changes to masked perturbation signals. The paper also curates a 42-dataset, 24.7M-cell, orthology-aligned cross-species corpus and evaluates under a dataset-held-out protocol against statistical, supervised, and pretrained baselines.
Strengths and weaknesses
Strengths
The data curation effort (orthology alignment across 19 studies, unified metadata vocabulary, 24.7M cells) is a good engineering contribution independent of the model. The sparse FiLM-conditioned tokenization and query-based decoder are a reasonable way to handle variable gene sets without dense padding, and the dataset-held-out protocol (excluding entire datasets, not just held-out cells) is the correct evaluation design for a generalization claim, in contrast to most of the cited supervised baselines (CPA, GEARS) which are evaluated within-dataset.
Weaknesses:
Zero-shot claim is unverified. Appendix F describes a "Stage 4" finetuning step and states baselines are "adapted... on the held-out training split." Table 1 never clarifies whether numbers are zero-shot or post-finetune. This determines whether the paper's central claim "generalizes under dataset-held-out evaluation" is supported at all.
CytoWave-S1 (control-only) vs CytoWave-S2 (full) ΔPCC differs by 0.001-0.005 across all five datasets, within reported standard deviation in most cases (e.g. 0.187±0.021 to 0.189±0.008; 0.108±0.008 to 0.107±0.004). The perturbation-aware stage shows no clear effect over masked-recovery pretraining alone. Stage 2A (L_expr) vs 2A+2B (L_align) is never isolated, so the InfoNCE alignment loss's contribution specifically is untested.
InfoNCE is structurally weak. Batch size 24, no negative-gathering across grad accumulation and 23 negatives despite 5x loss weighting.
Spearman correlation on log fold change is not reported. This is the field-standard metric for perturbation response ranking accuracy (used by GEARS, CPA, scGPT, STATE) and is absent from all results. ΔPCC/MAE alone do not establish that the model ranks differentially expressed genes correctly, which is the practically relevant claim for a perturbation-screening tool. Given the paper already identifies top-DE genes for masking, withholding this metric while reporting only Pearson-based scores is a significant omission.
Pathway evidence is circular. Top-15 pathways selected by prediction-truth agreement, then shown as evidence of agreement. Fig 6 also uses pseudobulk averaging, removing the per-cell noise the actual benchmark targets.
Stage numbering is inconsistent. The paper is framed as 'two-stage' throughout, but Appendix F references a 'Stage 4' finetuning step with no Stage 3 ever defined.
Missing baselines/citations:
STATE (Arc, 100M+ cells, same problem, mid-2025) and CellFlow (Klein et al. 2025). Neither cited nor compared. Related work discusses OT/flow/probabilistic population-level methods but only benchmarks the probabilistic one (scLDM). CellFlow fills the flow-based gap and is absent.
Questions
Can the authors confirm whether Table 1 numbers are zero-shot or post-Stage-4 finetune? Please report both for CytoWave.
Please add STATE/CellFlow to related work; compare directly if feasible.
If possible report an ablation of Stage 2A (L_expr only) vs full Stage 2 (L_expr + L_align) to isolate the InfoNCE alignment objective's contribution.
Report Spearman correlation of predicted vs. true log fold change (overall and restricted to top-DE genes) for CytoWave and all baselines. This is the most important metric that matters in perturbation modelling.
If the authors can address the weaknesses or justify them I may increase my score by one or two points. But for now I believe the paper is not ready.
Limitations
yes
Paper formatting concerns
none
Final justification
All ablations were ran and new results were presented.
Q1.Zero-shot and finetune
We apologize for the ambiguity in the current presentation. The results reported in Table 1 are obtained after downstream fine-tuning on the held-out training split of each evaluation dataset rather than under a zero-shot setting. We will revise the corresponding descriptions in both the main text and Appendix F to make the evaluation protocol explicit and avoid confusion. We will also correct the typographical error by removing the "Stage 4" designation, as downstream evaluation is not an independent training stage but rather the evaluation procedure following the two-stage pretraining pipeline. To further clarify the model's generalization ability, we will additionally include zero-shot evaluation results
These results remain consistent with our central claim that CytoWave learns transferable perturbation representations that generalize to held-out datasets.
Q2. Contribution of Stage 2 and Alignment Loss.
We agree that the improvement introduced by Stage 2 is not equally reflected across all evaluation metrics. In particular, the gains in ΔPCC are relatively modest on several datasets. At the same time, Stage 2 consistently improves MAE across all five benchmark datasets, with improvements exceeding the reported standard deviation on four datasets, indicating a consistent reduction in prediction error. It also yields generally positive improvements in ΔPCC20, although these gains are relatively small. We will revise the discussion to better reflect these observations and avoid overstating the effect of Stage 2 on ΔPCC. For the ablation study, we are currently conducting an additional ablation comparing Stage 2 with and without Lalign. Since this experiment requires whole stage 2 pretraining, it is still in progress and will be included in the revised manuscript.
Q3. InfoNCE settings.
Building on Q2, we agree that using only 23 in-batch negatives may limit the effectiveness of Lalign. We clarify that the 5× weight balances its gradient contribution but does not compensate for the limited number of negatives. We are therefore evaluating larger effective contrastive batches using cross-batch negative gathering and will report the resulting sensitivity analysis in the revised manuscript.
Q4. Evaluation Protocol and Spearman(logFC).
Thank you for this valuable suggestion. We agree that Spearman (logFC) provides a valuable, complementary ranking-based evaluation. We have added Spearman(logFC) to all benchmark datasets and baselines. The newly added results are fully consistent with our original conclusions, showing that our model accurately captures both perturbation magnitude and gene ranking. Our original evaluation focused on ΔPCC/ΔPCC_20 and MAE, which are widely used in perturbation-prediction benchmarks.
Q5. Case Study of Pathway Activity.
Thank you for raising this important point. We agree that Figure 6 should not be interpreted as an independent quantitative validation of model performance. Its primary purpose is to provide a qualitative biological interpretation of perturbation responses at the pathway level. To address this concern, we additionally performed a quantitative pathway-level evaluation based on perturbation-induced pathway response activities across all 50 MSigDB Hallmark pathways, rather than only the representative pathways shown in Figure 6. Specifically, for each perturbation, we first compute the predicted and observed gene expression changes relative to the corresponding control cells, aggregate these perturbation-induced changes into pathway response activities, and then evaluate their agreement using pathway response Pearson correlation, Spearman correlation, and MAE. The results are summarized below.
Furthermore, rather than presenting only representative pathways, the revised manuscript will include complete visualizations of all 50 MSigDB Hallmark pathways in the Supplementary Materials using the same visualization protocol. We also clarify that the pseudobulk pathway analysis is used only for pathway-level biological interpretation, where aggregating cells provides a more stable estimate of perturbation-induced pathway responses, and not for model training or benchmark evaluation. All primary benchmark results reported in the paper remain based on the original single-cell evaluation protocol. We will revise the corresponding discussion to explicitly distinguish qualitative biological interpretation from quantitative benchmark evaluation, thereby avoiding the impression of circular validation.
Q6. Stage Numbering and Downstream Evaluation.
Thank you for identifying this inconsistency. We will remove the erroneous “Stage 4” designation and rename the corresponding Appendix F subsection as “Zero-shot and Fine-tuning Evaluation.” This section describes the downstream evaluation protocols applied after the two-stage pretraining framework, including both zero-shot evaluation and task-specific fine-tuning, rather than an additional training stage.
Q5.Additional Baselines
We appreciate the suggestion. We have added both STATE and CellFlow as additional baselines and evaluated them under the same experimental protocol as all other methods. The corresponding results are summarized below and will be incorporated into the revised manuscript. Also, we will include more discussion about these studies in the related work section.