- Rating
- 4
- Clarity
- 2
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper introduces Measurement-Aware Score-Based Filtering (MASF). The main idea is to modify the forward process used in score-based filtering. Instead of using a standard diffusion process that moves the state distribution toward a Gaussian noise distribution, the authors define a forward process that moves the state toward the measurement space through the measurement operator H. This leads to a non-Markovian SDE representation of the forward process, and applying Markovian projection yields a Markovian SDE with the same marginal distributions.
The resulting SDE depends on two conditional means and , which are learned by simulating forward model to generate and minimizing objectives.
The method derives an exact likelihood score for linear measurement operators and proposes a Gaussian endpoint approximation for nonlinear measurement operators. This likelihood score is then combined with a prior score in a guided reverse-time sampler to perform the measurement update.
I find the main idea of making the score-model forward process aware of the measurement operator interesting and relevant to score-based filtering and data assimilation. My main concern is the limited metrics used to evaluate the method.
Strengths and weaknesses
Strengths:
-
Measurement-aware forward process: The main idea about incorporating the measurement process in the forward SDE is very appealing in a data assimilation task where the observation operator is known and is central to the filtering problem.
-
Sparse and nonlinear measurements: The paper is well motivated, as existing score-based filters struggle when measurements are sparse or nonlinear. The measurement-aware forward process in MASF provides likelihood guidance along the artificial path from state space to measurement space, rather than being a crude correction only at observed coordinates.
-
Theoretical derivations: The derivation provides a strong foundation starting with a non-Markovian SDE, followed by a Markovian projection, and deriving a closed-form likelihood score in the linear case.
-
Conditional-mean learning: Instead of learning the score, the method learns conditional means and , which are then used to construct the projected drift and likelihood approximation.
-
Good additional sensitivity experiments.
Weaknesses:
-
Initialization of the Guided Sampler in Alg 2: The sampling is initialized at with prior particles that are not distributed according to the measurement-aware forward process at time . A more literal initialization of the reverse process would involve or initializing from a distribution tied to the measurement endpoint.
-
Non-linear likelihood score: since the paper uses frozen means to obtain the Gaussian endpoint approximations, the non-linear case is theoretically less justified.
-
Exactness claim for the likelihood score: The sampler using guidance weights and , as a result, the implemented algorithm is not simply the exact posterior-score sampler. It would be nice to see performance with and in the ablation studies.
-
It is not fully clear how measurement information propagates to unobserved coordinates for sparse masks. Even in MASF, if the measurement operator is just a simple binary mask, the direct likelihood score may still be zero on unobserved coordinates.
-
Incomplete set of metrics for Bayesian filtering methods: The reported metrics are useful, but the evaluation should also include uncertainty or calibration metrics. Low RMSE does not necessarily imply good posterior uncertainty and could reflect ensemble collapse. Metrics such as posterior spread versus error, empirical coverage, rank histograms, or negative log-likelihood would help determine whether MASF improves uncertainty quantification or mainly improves ensemble means.
-
EnKF comparison depends strongly on ensemble size: In particular, EnKF improves from RMSE at to RMSE at , which is competitive with or better than the main-table MASF grid-mask result. The wall-clock time is higher in the reported setup, but ensemble forecast propagation is often parallelizable. Therefore, the practical comparison with EnKF may depend strongly on hardware and implementation. The authors should be more cautious in presenting wall-clock advantages as general rather than implementation-dependent.
-
Dimension-mismatch handling: The paper initially embeds measurements into the state space for notational convenience, but the experiments include dimension-reducing measurements such as grid masks and center masks. More details on how these cases are handled would be helpful.
-
Some empirical differences are small relative to uncertainty: In some cases, the estimated values are close, and since there are only five seeds, the statistical significance of the results is unclear.
-
Minor: Abbreviations such as NFE and CSI should be defined in the main text when first used, with one sentence of intuition.
Questions
Questions:
-
In Algorithm~1, why is the reverse sampler initialized with at ? Should the initialization instead be a forward-perturbed particle , with , or a sample near the measurement endpoint?
-
For nonlinear measurements, can the authors provide a small diagnostic or low-dimensional experiment comparing the frozen-conditional-mean Gaussian endpoint approximation with a more accurate likelihood-score estimate? This would clarify when the approximation is reliable.
-
In sparse linear mask settings, does the direct likelihood score have nonzero components on unobserved coordinates? If not, is the improvement mainly due to the learned prior score or conditional means propagating information from observed to unobserved regions?
-
Can the authors add uncertainty-calibration metrics such as posterior spread/error consistency, empirical coverage, or negative log-likelihood where feasible? Since this is a Bayesian filtering method, it is important to assess the quality of the posterior ensemble, not just the posterior mean.
-
Can the authors provide statistical significance tests, confidence intervals, or more seeds for cases where the reported improvements are close?
-
What are the possible failure modes of nonlinear endpoint approximation?
-
How is the case when the observation dimensions don't match the state dimension handled in this formulation?
Limitations
Yes.
Paper formatting concerns
NA
Final justification
I would like to maintain my score, given the covariance-correction results and prior-information-based filling in the case of sparse mask observation.
We thank the reviewer for the thoughtful comments. We address the main concerns below and will revise the manuscript accordingly.
Q1. Initialization of the Guided Sampler
We thank the reviewer for pointing this out. Our previous implementation used T=0.992 to avoid the terminal singularity at T=1 (Xue et al., 2024), causing the reverse sampler to start from a distribution that did not exactly match the forward-process endpoint. We have corrected this by redefining the cosine scheduler on t∈[0,1] with a(0)=1 and a(1)=0, so the reverse sampler now starts from the correct terminal distribution X1.
References
Q2. Nonlinear likelihood-score approximation
We thank the reviewer for this suggestion. We first identify the primary failure mode of Eq. (23) and then evaluate it against the exact likelihood score on a low-dimensional nonlinear measurement problem.
1. Missing conditional covariance in Eq. (23)
Eq. (23) matches only the conditional mean while neglecting the conditional covariance,
Cov(Z∣Xt)=Σt→1+at2Cov(D∣Xt) for D=X0−H(X0).
It therefore underestimates the conditional covariance and overestimates the likelihood-score magnitude. Since MASF already learns
E[D∣Xt]≈m1(Xt,t)−m2(Xt,t),
the missing covariance can be estimated from the predictor residuals,
$C_{\mathrm{corr}}(t) =\Sigma_{t\rightarrow1} + a_t^2\mathbb E[e(t)e(t)^\top], \quad e(t)=D-\bigl(m_1-m_2\bigr).$
2. Low dimensional exact-score diagnostic
We computed the exact likelihood score by numerical quadrature for Gaussian-mixture priors with 1D sigmoid and 2D speed measurements. To account for differences in score magnitude across times and measurements, we report the normalized root mean square error (NRMSE). We compared Eq. (23), the exact conditional covariance, and the residual-based covariance correction.
The approximation error is largest near t=1 and decreases as t→0. Both the exact conditional covariance and the residual-based correction substantially reduce the error, confirming that the neglected conditional covariance is the dominant source of approximation error.
We did not include this correction because covariance estimation is computationally expensive and unstable with only 10 ensemble members in high-dimensional settings. Instead, we clarify in the revised manuscript that the neglected conditional covariance is the main limitation of Eq. (23).
Q3-1. Unobserved coordinate likelihood score
We thank the reviewer for this insightful observation. As discussed in Q1, using the T=0.992 endpoint left a small residual likelihood score on unobserved coordinates during reverse sampling, although the theoretical likelihood score is exactly zero. The guidance weight was introduced solely to compensate for this numerical artifact.
We have therefore corrected the implementation, removed the guidance weight, and revised our previous interpretation that “MASF propagates measurement information through the likelihood score to unobserved coordinates.”
This change has virtually no effect on performance: for the Grid-mask experiment, the RMSE changes only from 0.151±0.021 to 0.150±0.015, while slightly reducing the variance. The revised implementation and explanation will be reflected in the manuscript.
Q3-2. Contribution of the learned prior
Under sparse measurements, the likelihood score is zero on unobserved coordinates, so reconstruction relies entirely on the learned prior.
To evaluate whether the prior exploits the measurement context, we compared posterior samples generated using the correct and shuffled measurements at each assimilation step. Correct RMSE, fair Continuous Ranked Probability Score (fCRPS), and Anomaly Correlation Coefficient (ACC) evaluate reconstruction quality under the correct measurement.
We define ΔRMSE and ΔfCRPS as Shuffled − Correct. Larger values indicate stronger reliance on the measurement context. Thus, lower Correct RMSE and Correct fCRPS, higher Correct ACC, and larger ΔRMSE and ΔfCRPS indicate more measurement-consistent posterior reconstruction.
MASF achieves the lowest Correct RMSE and Correct fCRPS, the highest Correct ACC, and the largest ΔRMSE and ΔfCRPS. These results indicate that the improvement comes from a learned prior shaped by the measurement-aware forward process, rather than from direct propagation of the likelihood score to unobserved coordinates.
Q4. Uncertainty calibration metric
We thank the reviewer for this valuable suggestion. As detailed in our response to Reviewer 1BiZ (Section 4), we have added fair Continuous Ranked Probability Score (fCRPS) and Spread-Skill Ratio (SSR). The results show that MASF improves not only point-estimation accuracy but also posterior quality and calibration.
W6. EnKF ensemble size and wall-clock comparison.
We thank the reviewer and agree that EnKF generally benefits from larger ensemble sizes, while wall-clock time depends on the hardware and implementation. Since all experiments were conducted under the same hardware and software environment, we present our results as an accuracy–runtime trade-off under a fixed experimental setup.
We selected EnKF with N=250 based on this trade-off rather than its maximum achievable performance. For the Grid-mask measurement, increasing the ensemble size to N=400 improves RMSE but increases runtime (180.3→263.5s for 1282). In contrast, for the nonlinear Sigmoid measurement, increasing the ensemble size from N=250 to N=400 yields virtually no RMSE improvement (0.629±0.189→0.630±0.180) while increasing runtime dramatically (173.5→1100.2s). We will clarify this trade-off in the revised manuscript.
Q5. Statistical significance
We thank the reviewer for this valuable suggestion. To perform statistical testing, we regenerated the experiments under the same settings using 10 random seeds and report paired t-tests with 95% confidence intervals for the closest comparisons (MASF vs. EnKF for Grid-mask and MASF vs. SSLS for Sigmoid). Statistical significance for Center-mask is discussed separately in our response to Reviewer eGTJ (Q3).
For the Grid-mask measurement, the RMSE improvement of MASF over EnKF was statistically significant, whereas the CSI difference was not. For the Sigmoid measurement, the RMSE difference was not statistically significant, while the CSI improvement was. Accordingly, we describe statistically insignificant results as comparable performance or a trend toward improvement.
Q6. What are the possible failure modes of nonlinear endpoint approximation?
We thank the reviewer for this suggestion. As shown in Q2, the primary limitation of the nonlinear endpoint approximation is the neglected conditional covariance. Although the exact conditional covariance and the residual-based correction substantially reduce this error, we did not include them because of their computational cost and unstable covariance estimation in high-dimensional settings. We will clarify this limitation in the revised manuscript.
Q7. Observation–state dimension mismatch
We thank the reviewer for this important question. The observation–state dimension mismatch is handled through a projection-based embedding.
Let P∈Rm×n(m<n) denote the projection operator selecting the observed coordinates. The clean measurement H(X0)=PX0 is embedded back into the state space as H(X0)=P⊤H(X0)=P⊤PX0, where P⊤P preserves the observed coordinates and sets the unobserved coordinates to zero.
Since measurement noise is applied only to the observed coordinates, the lifted covariance is singular. We therefore add a small independent Gaussian noise to the unobserved coordinates to obtain a positive-definite covariance.
Thus, the Grid-mask and Center-mask measurements are implemented using the embedded measurement H(X0), which is identical to H(X0) on the observed coordinates and differs only on the unobserved coordinates through zero padding.
W9. Abbreviations
We thank the reviewer for this careful reading. We will revise the manuscript to define all abbreviations upon their first appearance in the main text.