- Rating
- 5
- Clarity
- 4
- Confidence
- 4
- Originality
- 4
- Quality
- 3
- Significance
- 3
Read review
Summary
The authors proposed a straightforward and simple solution to current state-of-the-art anomaly detection (AD) models, in which the necessity of obtaining a text encoding is removed, allowing foundation model-style AD to go beyond vision-language models. They showed that the main function of the language encoder component in SOTA vision-language models is merely to provide decision weights, which can instead be learned directly by vision foundation models. They also suggested that having shared weights across classification and segmentation tasks in AD is actually a bottleneck and introduced a decoupled anomaly detector. Furthermore, they went above and beyond by suggesting that not only should the weights of these two tasks be decoupled, but that a similar idea should also be applied across hierarchical features.
They evaluated their model on two sets of industrial and medical AD datasets and showed that not only does it outperform the SOTA, but their 4-shot model also outperforms the full-shot Dinomaly.
Strengths and weaknesses
Quality: The paper's claims are well supported by both quantitative and qualitative experiments.
Clarity: The paper is very well written, with a clear and understandable flow. It effectively introduces the current challenges of vision-language foundation models and then presents the proposed solution.
Significance: While the results are promising compared to existing state-of-the-art vision-language methods for anomaly detection, the most significant contribution is that the 4-shot version of the model surpasses the full-shot Dinomaly model.
Originality: The paper proposes a novel yet straightforward technique for reducing the computational overhead of current models while achieving improved performance under various distribution-shift scenarios.
Questions
The authors propose CCA as their augmentation strategy, in contrast to random augmentation or no augmentation. However, the performance gain reported in Table 6(a), rows (c) and (d), appears marginal. Also, this improvement is demonstrated only on the MVTec dataset, where the model already achieves strong performance. Could the authors clarify why the gains are so limited and whether similar benefits are observed on more challenging datasets?
Additionally, why was CLIP ViT-L/14@336px selected as the backbone for the ablation study?
Regarding the medical-domain results, the proposed method underperforms competing approaches on both HeadCT and BrainMRI datasets. None of the three model variants approaches the performance of Bayes-PFL. Could the authors provide further analysis of the factors contributing to this performance gap?
On DTD dataset (as an example) on both image-level and pixel-level, their model outperformed the rest, however, the AUPR significantly dropped on the pixel-level, which is also the case in almost all other dataset. An interpretation for such behavior is required!
Limitations
Although the authors claim that the text encoder plays a limited role in vision-language foundation models for anomaly detection (AD), their proposed method may also be restricted in scenarios where textual information is the primary source of information. However, no experiments have been conducted to evaluate this potential limitation or to demonstrate how the model performs when text plays a more significant role.
Code is not provided!
Paper formatting concerns
N/A
Final justification
I appreciate the authors' efforts in addressing the reviewers' comments and providing detailed explanations and additional experiments. I was initially concerned about reviewer "SpbM"'s comment regarding the effect of different DINO variants on the results, but the additional experiment addressed this concern. Therefore, I stand by my score, provided that the code, trained model, and model weights are released upon acceptance.
We sincerely thank you for your professional review and strong support. We appreciate your recognition of UniADet as a novel yet straightforward solution with a clear and understandable flow, and claims well supported by both quantitative and qualitative experiments. We are especially encouraged that you highlighted our 4-shot result surpassing full-shot Dinomaly on Real-IAD as the most significant contribution. We address your concerns point by point below.
[TLSd-Q1] Why are the CAA gains so limited, and do they generalize?
The CAA is a multi-scale data augmentation, rather than a core contribution of this work. Its role is to expose the model to class-consistent variations across scales. These empirical results confirm that CAA is a useful data augmentation strategy for robust learning in visual anomaly detection in Table 6(a) (Page 8).
Specifically, CAA yields positive gains: +0.2 I-AUROC and +2.1 P-AUPR on MVTec, and +2.0 I-AUROC and +0.4 P-AUPR on VisA. The gains differ by metric, with a larger P-AUPR improvement on MVTec and a larger I-AUROC improvement on VisA, but they consistently confirm the utility of CAA across both datasets.
Given that CAA explicitly enriches scale variation, together with its larger image-level gain on VisA, which contains more small and scale-diverse defects, these results suggest that CAA can improve robustness when defect scales vary widely, particularly on datasets containing many small defects. We present this as an evidence-based interpretation rather than a universal claim.
[TLSd-Q2] Why was CLIP ViT-L/14@336px selected for ablation?
We selected the CLIP ViT-L/14@336px for three reasons. First, it is the standard backbone used by many zero-shot AD baselines compared in Tables 2 to 3 (Page 7), including AnomalyCLIP, Bayes-PFL, and AdaptCLIP, enabling controlled comparison. Second, CLIP lets us insert DCS/MS-DCS into both language-dependent and language-free variants while holding the visual representation fixed, as evaluated in Table 6(c) (Page 8). Third, the alignment analysis between text embeddings and learned visual decision weights requires a shared CLIP embedding space. Meanwhile, the DINOv2 and DINOv3 results in Tables 2 and 3 (Page 7) confirm that UniADet is not restricted to CLIP.
[TLSd-Q3] What contributes to the performance gap on HeadCT and BrainMRI?
Under the same CLIP backbone, UniADet achieves overall competitive zero-shot medical anomaly classification performance compared with the SOTA Bayes-PFL in Table 3 (Page 7). Across the three classification datasets, UniADet nearly matches Bayes-PFL in mean I-AUROC (96.7% vs. 96.8%) while clearly outperforming it in mean I-AUPR (96.7% vs. 94.7%). Thus, the two methods are comparable overall, rather than UniADet being consistently inferior. Specifically, UniADet surpasses Bayes-PFL on HeadCT with 97.0%/96.7% vs. 96.5%/95.5% I-AUROC/I-AUPR. On BrainMRI, its 95.7%/96.4% is 0.5% lower in I-AUROC but 4.0% higher in I-AUPR than Bayes-PFL’s 96.2%/92.4%, indicating a metric-specific trade-off rather than a systematic performance gap.
Importantly, UniADet removes the text encoder, resulting in a simpler architecture with substantially fewer learnable parameters and faster inference speed (Table 4, Page 7), while providing a more efficient basis for future improvement. Moreover, averaged over five medical anomaly segmentation datasets, zero-shot UniADet clearly outperforms Bayes-PFL, improving P-AUROC/P-AUPR from 87.7%/56.5% to 89.0%/59.2%. These results demonstrate that UniADet remains competitive in medical classification and is stronger in medical anomaly segmentation despite its substantially simplified design.
[TLSd-Q4] Why does pixel-level AUPR significantly drop on DTD?
Thank you for this careful and professional observation. We believe KSDD is the most representative case of the pronounced numerical gap between image-level AUROC and pixel-level AUPR. Our qualitative inspection shows that zero-shot UniADet sometimes misclassifies bright specular highlights caused by overexposure as defects. These false-positive pixels substantially reduce precision and thus P-AUPR. Importantly, this issue is clearly alleviated in the few-shot setting because normal reference images provide dataset-specific cues that such highlights are normal: P-AUPR improves from 31.8% in zero-shot to 45.0% in 1-shot (Appendix, Table A17).
More generally, image-level AUROC and pixel-level AUPR measure different tasks and should not be directly compared by their absolute values. Anomalous pixels are typically very sparse, so P-AUPR is highly sensitive to false-positive pixels because they directly reduce precision. In contrast, I-AUROC is less sensitive to such false positives under severe class imbalance. This metric property, together with the identified specular-highlight failure mode, explains the lower pixel-level AUPR on KSDD and its substantial improvement after introducing only one normal reference image.
[TLSd-Q5] No evaluation when text plays a more significant role.
We agree that the current experiments do not establish that text is unnecessary when textual or external semantic information plays a significant role. Our conclusion is narrower: a text encoder is unnecessary for the visually grounded universal AD benchmarks evaluated in this work.
First, UniADet targets anomalies that are visually distinguishable from normal patterns, as in the evaluated industrial and medical benchmarks. When an anomaly definition depends on external semantic knowledge, textual instructions, or context not recoverable from the image alone, a visual-only model may be insufficient, and language can be complementary or necessary. Second, because our experiments do not cover such semantically defined anomalies, we will not generalize our conclusion to these scenarios. We will narrow the corresponding claim, explicitly add this limitation, and identify optional language integration as future work. This scope clarification does not change the empirical conclusion that the text encoder is unnecessary under the evaluated visually grounded protocol.
[TLSd-Q6] Code is not provided.
We agree. As committed in the Abstract (Page 1), we will release the complete source code, trained weights, configurations, and evaluation scripts. We will also provide all hyperparameters, seeds, and environment details to ensure reproducibility.
We again thank you for your valuable time, strong support, and careful technical feedback. We hope that the above responses address your questions about CAA, the ablation backbone, medical results, pixel-level AUPR, limitations, and reproducibility.