- Rating
- 5
- Clarity
- 3
- Confidence
- 5
- Originality
- 4
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper presents SAFE-FEC, an adversarial data construction framework for factual error correction. It generates diverse factual mutations, refines and filters them through critique and semantic checks, and retains examples that remain difficult for current correctors. Experiments on three datasets show that SAFE-FEC consistently increases correction difficulty while preserving the validity and quality of the generated FEC instances.
Strengths and weaknesses
Strengths
- The paper addresses an important limitation of current FEC benchmarks and introduces a meaningful repair-frontier formulation.
- SAFE-FEC is a complete and well-motivated framework rather than a generic LLM-agent pipeline.
- The experiments are comprehensive, covering multiple datasets, correctors, judges, automatic metrics, quality evaluations, and ablations.
- The paper is generally clear, and the case study effectively illustrates the advantages of the proposed examples.
Weaknesses
- The full-model results in the ablation table differ slightly from the corresponding main results. The paper should clarify whether this is due to random runs, data subsets, or evaluation settings. 2.Figure 2 is somewhat dense and its workflow is not sufficiently clear, particularly regarding the semantic-guard failure path and the corrector-update loop.
- FECDATA is compared with human-written examples, while HOVER and FEVEROUS are compared with CECoR-generated examples. Adding a CECoR baseline on FECDATA would make the empirical narrative cleaner.
Questions
- The full SAFE-FEC row reported in the ablation table has values that are slightly different from the main FECDATA experimental results. Since the differences are small, they may come from independent LLM runs. However, the authors should explicitly explain the source of this discrepancy.
- The current dataset comparison is reasonable, but not fully uniform. FECDATA compares SAFE-FEC with human-written examples, whereas HOVER and FEVEROUS compare SAFE-FEC with CECoR-generated examples. If feasible, adding CECoR-generated examples on FECDATA would help answer whether SAFE-FEC is also stronger than existing synthetic construction methods on this dataset.
- The quality evaluation is useful, but I would like the paper to more explicitly discuss how it differs from real human evaluation. LLM-based pairwise preferences indicate that the generated examples are suitable, but they are still an automatic proxy metric. Adding a small-scale human validation in future work would further strengthen the evaluation and make the discussion more balanced.
Limitations
yes
Paper formatting concerns
NA
Final justification
Thank you for the detailed rebuttal. I appreciate the authors’ effort in conducting additional experiments to directly address the questions raised in my review. The added CECoR comparison on FECDATA and the human validation significantly strengthen the empirical evidence, while the clarification regarding the discrepancy between the main results and the ablation table is satisfactory.
Overall, the rebuttal increases my confidence in both the proposed framework and the experimental evaluation.
Dear Reviewer cYcx,
Thank you very much for your careful review. The three questions you raised are all highly specific and constructive. Following your suggestions, we conducted additional validation experiments. The detailed results are presented below and will also be incorporated into the revised manuscript.
Q1 (source of the discrepancy between the Full row and the main FECDATA results). Your guess is correct: it comes from independent LLM runs, not from a different data subset or a different evaluation setting. The two tables use exactly the same data. We will ensure consistent reporting of all metrics in the revised manuscript.
Q2 (adding CECoR-generated examples on FECDATA). We additionally conducted experiments on the FECDATA dataset to compare our method with CECoR. The detailed results are as follows:
Over these six correctors the average Judge drop against CECoR-generated data is 53.4%, larger than the 36.5% against human-written data, and the three judges agree on the direction: J-GPT -62.6%, J-DS -44.6%, J-Gem -54.1%. This demonstrates that SAFE-FEC is more challenging along both.
For the quality evaluation, we used Gemini to conduct pairwise preference comparisons between the samples generated by SAFE-FEC and CECoR on FECDATA. The detailed results are as follows:
Gemini prefers SAFE-FEC over CECoR-generated FECDATA in 82.00% of the pairs, above its preference for SAFE-FEC over the human-written FECDATA examples (71.11%) and above its preference on HOVER (66.93%) and FEVEROUS (66.81%). The newly added comparison is therefore the strongest of the four under this judge. We will add the more results for this comparison in the revised manuscript.
Q3 (how the quality evaluation differs from real human evaluation). Table 2 is an LLM-as-a-judge evaluation. We therefore ran the human validation you suggest. Three graduate-student annotators independently labeled 300 examples, 100 per dataset, in a blinded two-stage protocol in which the gold claim is revealed only after each annotator's own minimal correction has been locked. Taking the majority label per dimension over all 300 examples, the four properties that SAFE-FEC is meant to control pass at 98-100%: a real factual error in 98%, sufficient evidence in 100%, a unique correction target in 99%, and preserved semantic anchoring in 100%. The two weaker dimensions are fluency (94%) and whether the gold claim is itself supported by the evidence (81%), and the second concerns annotation we inherited from the source datasets rather than our construction.
Reviewer 3Wpu asked for the same audit, so we report the protocol in full there: the Stage A and Stage B question sets, the definition of a pass for each dimension, and the per-annotator labels broken down by dataset. In the revision we will report this audit alongside it as the validity check.
On presentation and clarity. We apologize for the parts you found hard to follow, in particular Figure 2. The two feedback paths that the figure fails to separate are the following. If the semantic guard rejects a composed mutation, the candidate is discarded immediately, no corrector is called, and the guard's stated reason is fed to the generator and judge prompt refiners before the outer loop regenerates. If the guard accepts, the candidate is tested against the detector-corrector for at most M = 2 rounds: when the corrector recovers the gold meaning the candidate is rejected as too easy and the evaluator's reason refines the generator prompts for the next iteration, and when the corrector fails twice in a row the Correction Resistance Score reaches κ = 2 and the candidate is accepted. We will improve the figures and address other clarity issues in the revised manuscript.