- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
This paper studies when classifier-free guidance (CFG) should be activated during diffusion sampling. The authors formulate the diffusion trajectory as a time-dependent information bottleneck and claim that the effectiveness of conditional information is not uniform throughout sampling. Through a Fisher-information analysis, they show that the guidance signal becomes more effective at injecting conditional information after some denoising time steps. From this they derive a rule that monitors conditional and unconditional score statistics batch-wise during sampling and switches CFG on once the estimated conditional gain crosses a threshold implied by their analysis.
Strengths and weaknesses
The paper is well-written and well-motivated, and the theorems are supported by proofs in the appendix. The authors make a good point that applying guidance uniformly in diffusion models may not be optimal, though it's worth noting this has been discussed and addressed in other papers too (e.g. Interval Guidance). Using ideas from information theory makes a lot of sense for guidance, and the paper motivates the information-bottleneck perspective well. That said, there are some issues worth addressing. The first is that the paper explores when guidance should be activated and ends up almost skipping the early, noisy diffusion steps, but this feels somewhat trivial, since at those steps both the conditional and unconditional predictions are mostly noise, so it's unsurprising they don't give useful guidance. My main concern is that if we simply picked an early time step and started applying guidance from there, we would likely see improvement as well, without any batch-wise statistics. So what's missing is an ablation comparing the proposed method against just randomly selecting an early step to activate guidance, to show whether the method really makes a difference. This is especially important because Table 4 and Table 1 show that a fixed mean threshold already nearly matches the adaptive version, which suggests the extra machinery may not be adding much. On top of that, while the goal and overall story are promising, the method doesn't seem very practical, since it needs to gather the guidance-gain statistics from a batch rather than a single sample, which makes it quite costly. There are also some minor issues. First, the qualitative comparison and visual results are quite limited. The quantitative results are also limited overall, with no comparison to other methods related to this idea. For example, the Flux experiment is restricted to 256 resolution, and it would be better to see it at a main resolution like 1024 with a higher guidance scale. Finally, there's a minor notation drift, where the squared-norm notation in Eq. 16 differs from that in Eq. 20.
Questions
Please referee to Strengths And Weaknesses section.
Limitations
The authors acknowledge the rectified-flow/deterministic-coupling limitation and the batch-wise (rather than single-sample) cost.
Paper formatting concerns
No major formatting or anonymity violations noted.
Final justification
I thank the authors for their detailed response and for the additional experiments provided during the discussion period, which help clarify several of the concerns raised in my review and provide a better understanding of the effectiveness of the proposed method. My main concern was whether the method remains effective under ordinary single-image inference, and the completed B = 1 evaluation on FLUX at 1024x1024 on HPSv2.1 addresses this directly. This supports the authors' explanation that batch averaging primarily reduces the variance of the activation statistic rather than being required for the method to operate. I consider my concerns mostly resolved and addressed, therefore I am raising my rating. I would ask that these results be included in the final version.
We sincerely thank the reviewer for the careful reading and constructive feedback. To provide a clear and structured response, we organize the comments into seven main questions. We address each question below.
If you are not satisfied with our answers or have more questions, please let us know, so that we can try our best to answer any further questions before the deadline.
Q1: What is the conceptual contribution beyond simply skipping early noisy steps?
We agree that strong CFG is unlikely to help in the extremely noisy regime, consistent with Interval Guidance. Our question, however, is not merely whether early CFG should be avoided, but when the conditional signal becomes informative enough to activate it. A qualitative noise argument does not determine this model-dependent transition.
This distinction is important because identifying a useful activation time is a quantitative and model-dependent problem. A heuristic argument that both branches are unreliable under heavy noise does not specify the transition point. Our contribution is to formulate this transition through a time-dependent information bottleneck and derive a Fisher-information balance condition that characterizes the activation region. We then translate this theoretical condition into an online, observable score statistic and a training-free threshold-crossing rule, making the criterion directly applicable in practical diffusion sampling.
This distinction is also reflected in our threshold ablation in Appendix E.2: different activation thresholds lead to substantially different results, and activating guidance earlier does not automatically improve generation. For example, Appendix E.2 further shows that activation timing matters: logβ∗=5.5 underperforms the baseline, while values around [5.9,6.3] improve both FID and IS. Thus, merely delaying CFG is insufficient; the transition location must be identified.
Q2: Does an arbitrary or randomly selected activation time work equally well?
We test a batch-wise random boundary τ∼U[0.7,1], independent of the score statistics:
Because reverse sampling proceeds from t=1 to 0, the random rule typically activates CFG earlier than th=0.7. It therefore shifts the fidelity-confidence trade-off toward very high IS but substantially worse FID. Arbitrary randomization does not reproduce our balanced improvement, showing that the activation location matters.
Q3: What is the benefit of adaptive stopping when the fixed mean performs similarly?
We agree with the reviewer that, on SiT-XL/2, the fixed boundary th=0.7 in Table 1 and th=0.68 in Table 4 performs similarly to our adaptive criterion. We do not intend to overstate the incremental advantage of batch adaptation in this particular setting.
However, th=0.68 in Table 4 is not a pre-specified or universally known boundary; it is obtained post hoc from the stopping-time statistics produced by our criterion. Without such a criterion, the boundary would still need to be selected through model-specific validation or manual search. This similarity is consistent with our theoretical analysis rather than contradicting it.
More importantly, our criterion provides a more interpretable procedure for selecting the activation hyperparameter. Figure 1 yields a model-specific calibration curve through Eq. (22), from which a plausible range of logβ∗ can be estimated before conducting a full generation benchmark. The curve therefore substantially narrows and informs the subsequent hyperparameter search. In contrast, fixed Interval Guidance directly selects th in the time domain, where no analogous model-dependent calibration curve is available and the effective boundary must generally be identified through empirical sweeps. Thus, although both approaches contain a one-dimensional hyperparameter, our formulation makes its selection more principled, interpretable, and easier to initialize.
Finally, the similarity between the adaptive rule and the fixed mean boundary is consistent with our large-batch analysis. As the batch score statistics concentrate, the stochastic stopping time approaches a deterministic interval boundary. Hence, the fixed-mean result does not make the adaptive criterion redundant; rather, it confirms that the criterion identifies the effective deterministic activation region that fixed-boundary tuning would otherwise need to discover empirically.
The mean remains stable while the variance decreases with batch size. Thus, as batch statistics concentrate, the stochastic rule approaches a deterministic interval. The main benefit is therefore not guaranteed superiority over an already well-tuned boundary, but a principled mechanism for discovering that effective region from model dynamics.
Q4: Does batch-wise estimation introduce substantial computational overhead?
The statistic is computed only from the current mini-batch; it requires no reference dataset or accumulation across inference batches. Conditional and unconditional inputs are concatenated and evaluated in one batched denoiser forward pass, as in standard CFG. The only additional operations are squared score norms, a batch mean, and a scalar comparison. No auxiliary network, training, backward pass, or iterative optimization is required.
Under identical hardware and evaluation settings with 50,000 samples and 250 steps, the baseline takes 12 h 37 min and ours 12 h 39 min, corresponding to only about 0.26% wall-clock overhead. Moreover, Table 2 shows improvements for every tested batch size B∈{4,8,16,32}; even B=4 is sufficient for a useful estimate.
Q5: Are the comparisons with related guidance methods sufficiently broad?
We agree that broader empirical comparisons would further strengthen the evaluation. We selected Interval Guidance as the primary related baseline because it is the most directly comparable method.
To broaden this comparison, we additionally evaluate a fixed-interval strategy on DiT-XL/2 and SD3 by transferring the activation boundary th=0.7T used for REPA, while using the same guidance scale as our method.
On DiT-XL/2, our criterion achieves substantially better FID than the transferred fixed interval, while the latter obtains a higher IS. Since both methods use the same guidance scale, this difference is attributable to their activation schedules rather than to ω. The unusually high IS of the transferred interval suggests that the uncalibrated boundary shifts the sampler toward an IS-favoring operating point, with stronger effective class conditioning but degraded distributional fidelity. In contrast, our criterion achieves a more balanced FID–IS trade-off.
On SD3, the transferred fixed boundary degrades CLIP, Aesthetic, and HPS scores, whereas our score-based criterion remains effective. This indicates that the activation region identified for one model and data regime does not transfer reliably to a substantially different architecture and task. We emphasize that this is a cross-model transfer test rather than a fully tuned comparison against Interval Guidance on SD3.
These results show that a fixed activation boundary selected for one model family does not necessarily transfer reliably to another.
Q6: Additional high-resolution and qualitative results
A FLUX experiment at 1024×1024 with higher guidance is in progress, and we will update the response if completed during discussion. Table 3 already reports SD3 at 1024×1024 and guidance scale 7.5, providing initial evidence in a high-resolution, high-guidance regime.
Q7: Notation inconsistency
We thank the reviewer for identifying this notation inconsistency. We will replace the scalar-style squared notation in Eq. (16) with ∥sθ(⋅)∥22, making it consistent with Eq. (20) throughout the revised manuscript.