- Rating
- 4
- Clarity
- 2
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
This work presents a novel noisy-label selection scheme depending on gradient magnitude and its directions. For 11 noisy-label detection settings, GradTrack achieves the highest average performance. The authors integrate this approach with several existing LNL baselines, and it is shown that GradTrack enhances performance in CIFAR-100N, WebVision, and Clothing1M datasets.
Strengths and weaknesses
The paper demonstrates clear performance gains over existing algorithms. In particular, it shows that the proposed method outperforms prior approaches under various noisy-label settings, which supports the effectiveness of the method in learning with noisy labels.
While the proposed method demonstrates a significant performance gain under severe noise conditions (e.g., CIFAR-10N-Worst with ~40% noise rate), its accuracy drops to 70% in a low noise regime (e.g., CIAFAR-10N-Agg with ~9% noise rate). I attribute this degradation to the over-cleansing effect. That is, the algorithm mistakenly filters out hard-yet-clean samples as noise, leading to a reduction in the performance. There is a lack of analysis on these aspects.
Questions
- Although the proposed method achieves strong results under synthetic noisy-label settings, its performance on CIFAR-10N (Agg. 0.09), a real-world human-annotated noisy-label benchmark, is significantly lower than that of competing methods. Could the authors clarify why the method generalizes well to synthetic noise but struggles under real-world label noise?
- In Table 1, the results are presented for different types of label noise. However, it remains unclear whether the proposed method becomes more or less effective as the noise ratio increases or decreases under the same noise setting. Could the authors provide additional analysis or comparisons to show how the relative performance gain of the proposed method changes with changing noise ratios within the same dataset and noise type?
- The authors are dividing samples into three groups (low, mid, high) based on gradient magnitudes. Could the authors clarify whether this grouping rule is robust to different noise ratios?
Limitations
- A limitation is that group partitioning based on gradient magnitude may be sensitive to variations in noise ratio, potentially leading to performance degradation. It needs analysis on these aspects.
Paper formatting concerns
Overall, the paper is readable, but the tables and figures could be made more consistent.
We sincerely thank Reviewer RE1F (R3) for the thoughtful, constructive, and detailed feedback. We address R3’s specific comments below and welcome any further discussion.
R3-Q1. "Over-cleansing" at low noise rates.
We agree with R3 that the performance drop on CIFAR-10N-Agg is a result of over-cleansing. In this setting, the underlying ranking of noise samples is excellent (AUC 97.78) and with a high recall (92.81%), but a low precision (55.21%). Across the other 10 settings, recall stays similarly high (96.59±2.83%, range 91.39–99.20%), while precision averages much higher (83.46±10.46%). So GradTrack catches nearly all noisy samples, but at the cost of also flagging many clean ones, i.e. over-cleansing. On CIFAR-10N Agg., the confusion matrix is:
Table R3.1Here the GradTrack outcome’s effective predicted noise rate is 15.14%, which harms the overall performance because CIFAR-10N Agg. has the lowest base noise rate 9.01%.
Appendix A.3/Fig. 7 shows that raising explained-variance threshold ρ from 0.85 to 0.90 already recovers F1 to 80.79% and an effective predicted noise rate of 9.73%, so this is a threshold-calibration issue at low noise rates, not a failure of the underlying signal. This suggests that the intrinsic problem here is that GradTrack is noise rate agnostic; a design choice we made to make GradTrack generic by not assuming knowledge of the noise rate. We will add this precision/recall and over-cleansing analysis in Appendix A.3 to explain this failure mode more clearly in the revised paper.
R3-Q2. Synthetic vs. real-world noise.
GradTrack performs well on the other two real-world noise settings (CIFAR-10N Worst 0.4: 91.63; CIFAR-100N Human 0.4: 79.12), and its underperformance on CIFAR-10N Agg. 0.09 is the same over-cleansing/threshold-calibration issue discussed above, not a general weakness on real-world noise.
From a performance comparison point of view, GradTrack (69.23) trails CORES (80.50) [ref 3-1] and SIMIFEAT-R (79.16) [ref 3-2] on CIFAR-10N Agg. 0.09, so we further analyze why these methods perform better in this specific low-noise setting. SIMIFEAT-R’s per-class noise-transition estimate appears well matched to this low-noise case, but this advantage does not hold uniformly across settings: GradTrack has higher average F1 across all 11 settings (87.40 vs. 83.02). CORES shows a similar sensitivity to thresholding; it performs well on CIFAR-10N Agg. but has much lower average F1 across all settings (61.58). In contrast, GradTrack’s GMM estimator does not assume a known noise rate, which improves robustness across settings but can be less calibrated in very low-noise regimes. Given that real-world noise rates can vary substantially across domains, e.g., in medical image grading tasks, the inter-observer inconsistencies (noises) can be as large as 65% [ref 3-3], specific tuning a method toward high or low noise ratios may not be a good strategy. A practical consideration to determine the noise ratio can be randomly relabelling a small proportion of the dataset and then tuning GradTrack (or any other noisy sample detection methods) parameters toward those, but this is orthogonal to the main objectives of GradTrack; hence, we will discuss this in the revised paper.
R3-Q3. Varying noise ratio.
The requested noise-ratio analysis is shown in Fig. 5, for instance-dependent noise with noise rate η=0.1–0.5 on three datasets: CIFAR-10/100/Tiny-ImageNet. GradTrack consistently outperforms SIMIFEAT-V [ref 3-2] across the sampled noise rates and remains competitive at low noise levels on CIFAR-10, indicating stronger robustness to varying noise severity. On the other hand, the concave shape of the noise ratio analysis in terms of performance suggests that both GradTrack and SIMIFEAT-V, the top-performing methods, handle 30-40% noise ratios the best.
R3-Q4. Robustness of the low/mid/high grouping to noise ratio.
Thank you for the suggestion. We have run the requested noise ratio vs three groups and will add it to the appendix: for CIFAR-10, CIFAR-100, and Tiny-ImageNet under instance-dependent noise at η∈{0.1,0.2,0.3,0.4,0.5}, we compare the three partition ratios from Appendix A.4 (20-60-20, 25-50-25, 33-33-33):
Table R3.2Across all 15 dataset and η combinations, the std across the three partition ratios is at most ±1.05, indicating the grouping partition is insensitive to the noise ratio change.
References
[ref 3-1] Cheng, Hao, et al. "Learning with instance-dependent label noise: A sample sieve approach." arXiv preprint arXiv:2010.02347, 2020.
[ref 3-2] Zhu, Zhaowei, et al. "Detecting corrupted labels without training a model to predict." ICML, 2022.
[ref 3-3] Chokuwa, Sharon, et al. "Divergent Domains, Convergent Grading: Enhancing Generalization in Diabetic Retinopathy Grading." WACV 2025.